Data Loggers For All Applications
Data Loggers for All Applications
1 - 800 - 956 - 4437
M-Th 8A-5:30P(EDT)
Fri     8A-4:30P(EDT)
Find a data logger by selecting an application from the list below.
Request Pricing & Information
Home -> Voltage and Current Data Loggers -> DC Voltage and Current Data Loggers

DC Voltage and Current Data Loggers

Large Selection

We offer a variety of data loggers that are suitable for measurement of DC voltage and DC current. There are models that are specifically designed for voltage and current measurements. They typically are lower cost and are easier to set-up but offer less flexibility. We also have a great selection of general purpose data loggerers that can measure DC voltages, currents and also allow the measurement of other input signals types.

If you need to monitor AC Voltage or Current, please click the following link to our: AC Voltage and Current Data Logger Page . If you have to monitor a mix of AC and DC voltage and/or current inputs, we have a great selection of Universal Input Data Loggers that can be outfitted with transducers to measure almost any type of input - from mV and uAmps to thousands of volts or amps - click the following link for our Universal Input Data Loggers .

Transducer Support

If you need to measure voltages and currents that are beyond the standard input ranges of these data loggers, we can provide transducers that are suitable for up to hundreds or thousands of amps that work with our general purpose data loggers that allow measurement of most voltages and currents found in residential, commercial or industrial applications. These loggers also allow the measurement of other input signals types besides voltage and current.

For more information on transducers, go to our tutorial page for Voltage and Current Measurements. Please call us at 800-956-4437 and we will help you design a system to meet your exact requirements.



Electrocorder

DC-3V-60 Three Channel DC Voltage Logger

DC-3V-60

DC-3V-60 Three Channel DC Voltage Logger


  • Three Channel: 60Vdc (D1, D2 & D3 to Common)
  • Monitor charging circuits, PV (photovoltaic) cell, DC motor, and many other application.
  • Accurately record DC voltages up to 60Vdc.
  • Records VAvg, VMax & VMin on all 3 channels. Data is stored in non-volatile memory.
  • Optional DC current transducers available.





Electrocorder

DC-3VA Two Channel Voltage and Current Logger

DC-3VA

DC-3VA Two Channel DC Voltage and Current Logger


  • 2 Channels Voltage (300V), 1 Channel Current +/-10A or +/-100A
  • Records DC voltage and current
  • Monitor charging circuits, PV (photovoltaic) cell, DC motor, and many other application.
  • Accurately record DC voltages and DC current.
  • Records VAvg, VMax & VMin on 2 channels, Iavg, Imax & Imin on 1 channel.
  • Recorded data is uploaded to a PC for analysis with Free Electrosoft Software.
  • Selectable averaging period to suit each situation, accurate to <1% of range.





Electrocorder

PV-3 Solar Data Logger

PV-3

PV-3 Solar Data Logger


  • Records Solar Irradiance, 0-1500W/m-2
  • PV system output Vdc to 300V, Idc to 100A
  • Monitor charging circuits, PV (photovoltaic) cell, DC motor, and many other application.
  • Accurately record DC voltages up to 60Vdc.
  • Kit includes logger, fused voltage input leads, DC current probe, pyranometer, USB lead, 12Vdc PSU, software and carry case.







dataTaker Data Loggers

dataTaker Data Loggers


dataTaker data loggers can record voltage, current, resistance, frequency and transducers while providing additional features and functionality.
  • Expandable up to 300 universal analog inputs
  • Logging rates of up to 25Hz
  • Up to 10 million data readings
  • Ethernet, USB, or RS-232 Communication with PC
  • Transducer, SDI-12 and Modbus Sensor Support
  • Built-in Web Server, FTP, and an Enhanced Web Interface







Grant Data Loggers

Grant Data Loggers


Grant data loggers offer portable, laboratory grade data loggers that can record current, voltage, resistance, temperature with the use of analog inputs.
  • Up to 32 universal analog inputs
  • Logging rates of up to 100Hz
  • Up to 14 million data readings
  • USB and RS232 communication ports
  • Models come in Ethernet or Wi-Fi







wireless voltage data logger

A1-09

A1-09 Wireless Voltage Data Logger


Wireless voltage monitor that can handle up to 6 0-5Vdc Analog inputs.
  • Ambient temperature sensor
  • 6, 0-5V Inputs
  • 2 Digital inputs
  • Battery or AC power
  • Up to 250' range
  • 250 Sample buffer







wireless current data logger

A1-10

A1-10 Wireless Current Data Logger


Wireless current monitor that can handle up to 6 4-20mA inputs.
  • Ambient temperature sensor
  • 6, 4-20 mA Inputs
  • 2 Digital inputs
  • Battery or AC power
  • Up to 250' range
  • 250 Sample buffer







dc current data logger

L322

L322 DC Current Data Logger


  • 2 Input channels with screw terminal connectors
  • Input range of -20 to + 20 mA DC
  • Storage rate of 8x per second to once/day
  • Store up to 240,000 measurements
  • USB communication interface
  • Simple LED status display
  • Battery powered







dc voltage data logger

L432

L432 DC Voltage Data Logger


  • 2 Input channels with screw terminal connectors
  • 3 Input range from 100 mVDC to 10VDC
  • Storage rate of 8x per second to once/day
  • Store up to 240,000 measurements
  • USB communication interface
  • Simple LED status display
  • Battery powered







l481 high voltage data logger

L481

L481 DC High Voltage Data Logger


  • Measures up to ±850 VDC
  • Storage rate of 8x per second to once/day
  • Store up to 240,000 measurements
  • USB 2.0 communication interface
  • Simple LED status display
  • Battery powered







usb voltage data logger

EL-USB-3

EL-USB-3 USB Voltage Data Logger


  • 0-30 VDC Measurement Range
  • User programmable sample rate and alarm limits
  • 32,000 Point storage capacity
  • USB interface for set-up and download
  • Configuration and graphing software included
  • Screw terminal connections
  • Replaceable battery







usb current data logger

EL-USB-4

EL-USB-4 USB Current Data Logger


  • 4-20 mADC Measurement Range
  • User programmable sample rate and alarm limits
  • 32,000 Point storage capacity
  • USB interface for set-up and download
  • Configuration and graphing software included
  • Screw terminal connections
  • Replaceable battery







wireless voltage data logger

RVR-52

RVR-52 Wireless Voltage Data Logger


  • Voltage Pulse or Event Measurement (0 - 6.5 V)
  • Water resistant
  • 16,000 point memory
  • Works with the RTR-57C/U, RTR-50 or RTR-5W Data Collectors
  • Optional Soil Moisture Sensor
  • Models starting at $259.00







71 voltage data logger

VR-71

VR-71 Voltage Data Logger


  • 2-channel voltage logger
  • 4 measurement ranges per channel: ±1, ±2, ±6, ±15
  • 20 programmable measurement rates from 20 Hz to once per hour
  • Programmable scaling and display units
  • Stores 8000 points/channel
  • Includes Windows software to setup, monitor, download, graph and export data





Related Application Notes

Below features our collection of application notes and case studies related to this page.

Monitoring Floor Panel Separation with a String Pot

Earth Ground Fault Remote Alarming & Fault Detection for Power Grids

Data Monitoring for a Rural Development Charity

Monitoring Solar Hot Water Systems

Testing Filtration Systems in Pools and Hot Tubs

Vehicle Data Acquisition For Component Reliability Testing

Data Logging With Remote UMTS Access In Natural Gas Dehydration Plants

Greek Gov. Agency Uses Unique Marine Data Buoy To Monitor Coastline

View all related application notes



Request Pricing & Information

If you need information right away or prefer to speak with a person, call us and one of our Experienced Applications Engineers will be happy to talk with you. You can reach us at 1-800-956-4437 during our normal business hours Monday - Friday from 8am to 6pm (EDT).

After filling out the form below, an applications engineer will contact you within at least one business day.

Indicates a required field.

Fields that are not required are recommended to be filled out so that we can better assist you.

Request Form

Name Address 1
Email Address 2
Phone # City
Company State
Job Title Zip
Fax # Country
Product(s)

of Interest
Application
Additional

Information
Human Verification What is the next number after 2?  
Newsletter Sign Up - Here at CAS Data Loggers we are constantly publishing new articles, and now you can receive monthly emails to see what's new. By signing up for our monthly newsletter, you will also receive the newest application notes where our products are being used and many other resources such as white papers, videos, technical articles and new product information.

Home | About CAS | Policies | Distributor Login | Systems Integrators

©2011 Computer Aided Solutions, LLC.