Data Logging GuidesNews -> Product Anouncements -> CAS DataLoggers Helps You Get Ready for RICE NESHAP!

CAS DataLoggers Helps You Get Ready for RICE NESHAP!

Date Published: July 23, 2012
Download the PDF version


dataTaker dataloggers Help You Ensure Regulatory Compliance by 2013

Manufacturers across the country are scrambling to prepare for RICE NESHAP, an incoming EPA regulation intended to reduce pollutants from several categories of new, existing and reconstructed stationary engines. The focus is on air toxics, and all applicable diesel and non-diesel engines must be retrofitted with an emission control product to meet the new requirements by 2013. Every diesel engine is affected by this rule in some way, forcing the industry to profile all engines to determine standard levels, install all required devices, and then monitor the refitted engines to ensure they’re compliant and functioning as intended. It’s especially critical to measure engine temperature and pressure in diesel engines, but RPM and many other values also need to be closely monitored. CAS DataLoggers has your complete compliance toolkit with the new Series 3 dataTaker DT85 Intelligent Data Loggers, advanced monitoring products to ensure your engines are properly retrofitted, tested and documented for full RICE NESHAP compliance.

During the monitoring phase of compliance, dataTaker dataloggers are ideal for monitoring several factors such as engine temperature during operation in diesel engines. For example, under RICE NESHAP, engines over 500 HP must now use a continuous parametric monitoring system (CPMS) to measure pressure drop across the catalyst. Catalyst inlet temperature must also be measured to ensure it stays between 450°-1350°F. Here the dataTaker DT85 is ideal as a single solution, acting as a catalyst monitor to measure both the engine temperature and the pressure drop. Connecting to most sensors and data measurement sources,  the DT85 has the flexibility to monitor nearly any physical value at high accuracy while connecting to a large number of inputs. Measuring RPM and many other factors, the DT85 features 16 to 48 universal analog sensor channels, 12 digital channels, 4 high-speed counter inputs, phase encoder inputs, and programmable serial sensor channels. The datalogger can scale and log almost any physical value including temperature, voltage, current, 4-20mA loops, resistance, strain gauges, frequency, and more.

The DT85 makes 18-bit resolution measurements across a ±30 V input measurement range and is expandable up to 900 analog inputs as needed. A clear built-in display shows all current readings, while the data logger can store up to 10 million data points in user-defined memory and gives users independent control of schedule size and mode to log only as long as needed. Users can choose to archive data on alarm event, copy to USB memory and transfer via FTP, providing data directly to offices over the internet or mobile phone network without the need for polling or specific host software.

These dataTaker dataloggers are famous around the world for their rugged construction enabling them to stand up to rough handling and extreme environments, lasting over years of constant use. Advanced communications capabilities include RS232 with modem support, USB, Ethernet and USB memory stick ports so that users can connect to the DT85 either locally, remotely or over the Internet. This versatility is increased with the logger’s multiple SDI-12 sensor networks, Modbus for SCADA systems, FTP and Web interface, making the DT85 ideal for your regulatory monitoring needs.

FREE graphical interface software is built-in with dataTaker data loggers—dEX is a user-friendly resource allowing users to quickly configure the logger and view real-time measurements, calculations, and diagnostic information. Users can also see their real-time data as mimics, trend charts or tables, and retrieve historical data for analysis. Users get a quick start on compliance since dEX has no applications to install, runs directly from a web browser, and can be accessed either locally or remotely anywhere that a TCP/IP connection is available including worldwide over the Internet. Users can view dEX using any of the logger’s built-in communications ports including Ethernet, USB and RS-232.

For more information, the EPA RICE NESHAP Fact Sheet provides general information on the ruling. Ensure your RICE NESHAP compliance as soon as possible with dataTaker dataloggers!

Request More Information

If you need information right away or prefer to speak with a person, call us and one of our Experienced Applications Engineers will be happy to talk with you. You can reach us at 1-800-956-4437 during our normal business hours Monday - Thursday from 8am to 5:30pm and Friday 8am to 4:30pm (EST).

After filling out the form below, an applications engineer will contact you within at least one business day. Fields that are not required are recommended to be filled out so that we can better assist you.

Request Form

Submit the product or application you are interested in and we'll contact you. Need immediate information? Give us a call at 800-956-4437.

Name (required):
Email (required):
Company:
Phone #:
City:
State:
Country:
Product(s) of Interest:
Application:
Additional Information:
Human Verification What is the next number after 3?  

**Your contact information allows us to provide you with pricing information. We never sell or distribute your information. See our Policies page for more information.


Visit our Blog Follow us on Facebook Follow us on LinkedIn Follow us on Twitter Find us on Google+
Home | About CAS | Policies | Distributor Login | Systems Integrators

©2013 Computer Aided Solutions, LLC.