<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Data Logger Inc Blog</title>
	<atom:link href="http://www.dataloggerinc.com/dataloggerinc_blog/feed/" rel="self" type="application/rss+xml" />
	<link>http://www.dataloggerinc.com/dataloggerinc_blog</link>
	<description>News and information on data loggers and data recording equipment</description>
	<lastBuildDate>Thu, 26 Aug 2010 13:06:05 +0000</lastBuildDate>
	<generator>http://wordpress.org/?v=2.9</generator>
	<language>en</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
			<item>
		<title>Low Cost Event/Count Data Loggers</title>
		<link>http://www.dataloggerinc.com/dataloggerinc_blog/2010/08/low-cost-eventcount-data-loggers/</link>
		<comments>http://www.dataloggerinc.com/dataloggerinc_blog/2010/08/low-cost-eventcount-data-loggers/#comments</comments>
		<pubDate>Thu, 26 Aug 2010 13:06:05 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Specialty Data Loggers]]></category>

		<guid isPermaLink="false">http://www.dataloggerinc.com/dataloggerinc_blog/?p=126</guid>
		<description><![CDATA[<p>The new EL-USB-5 captures event or state changes or provides pulse counting in a low cost data logger with a built in USB interface for set-up and data download. The EL-USB-5 is battery powered and can store up to 32,000 events or state changes in its own memory. It can capture events, either rising or falling edge, which occur as fast as 5 times per second or state changes twice a second. When used in pulse counting mode, it can capture pulses occurring at up to 100 Hz during one of 8 user programmable logging intervals.</p>
<p class="wp-caption-text">EL-USB-5</p>
<p>The EL-USB-5 can accept [...]]]></description>
			<content:encoded><![CDATA[<p>The new EL-USB-5 captures event or state changes or provides pulse counting in a low cost data logger with a built in USB interface for set-up and data download. The EL-USB-5 is battery powered and can store up to 32,000 events or state changes in its own memory. It can capture events, either rising or falling edge, which occur as fast as 5 times per second or state changes twice a second. When used in pulse counting mode, it can capture pulses occurring at up to 100 Hz during one of 8 user programmable logging intervals.</p>
<div id="attachment_127" class="wp-caption aligncenter" style="width: 310px"><a href="http://www.dataloggerinc.com/dataloggerinc_blog/wp-content/uploads/2010/08/EL-USB-5.jpg"><img class="size-medium wp-image-127" title="EL-USB-5 Event Data Logger" src="http://www.dataloggerinc.com/dataloggerinc_blog/wp-content/uploads/2010/08/EL-USB-5-300x225.jpg" alt="EL-USB-5 Event Data Logger" width="300" height="225" /></a><p class="wp-caption-text">EL-USB-5</p></div>
<p>The EL-USB-5 can accept input voltages of up to 24VDC allowing use with many common types of systems including PLC’s and PAC’s. It also has a mode where it can be used with a voltage free, dry contact such as a magnetic reed switch, relay or microswitch. LED’s on the data logger provide a quick indication of the logging state. A built in USB interface makes it easy to download data to a PC.</p>
<p>The data logger is supplied with EL-USB-WIN software, a very easy to use Windows based application that can be used to configure the recording parameters and download stored data. EL-USB-WIN is compatible with Windows 2000/XP/Vista and Windows 7 including 32 and 64 bit versions. The EL-USB-5 also comes with a set of clip leads for attachment to the signals source and a replaceable lithium battery that provides up to 1 year of operation.</p>
<p>The EL-USB-5 is ideal for capturing events such as door open/closing, equipment up/down time or counting machine cycles. For more information click here for the <strong><a href="../../datasheets/lascar-el5.pdf">EL-USB-5 Data Sheet</a></strong>, or call us at <strong>(800) 956-4437</strong>. For more information on all of the data logging products we offer, visit our web site, <strong><a href="../../">www.DataLoggerInc.com</a></strong> .</p>
]]></content:encoded>
			<wfw:commentRss>http://www.dataloggerinc.com/dataloggerinc_blog/2010/08/low-cost-eventcount-data-loggers/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Process Current Data Loggers for 4-20 mA Signals</title>
		<link>http://www.dataloggerinc.com/dataloggerinc_blog/2010/08/process-current-data-loggers-for-4-20-ma-signals/</link>
		<comments>http://www.dataloggerinc.com/dataloggerinc_blog/2010/08/process-current-data-loggers-for-4-20-ma-signals/#comments</comments>
		<pubDate>Thu, 12 Aug 2010 13:26:52 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Current/Voltage Data Loggers]]></category>
		<category><![CDATA[current data logger]]></category>

		<guid isPermaLink="false">http://www.dataloggerinc.com/dataloggerinc_blog/?p=123</guid>
		<description><![CDATA[<p>CAS Dataloggers has a great selection of equipment data loggers to monitor and record 4-20 mA process current signals provided by many common types of sensors and transducers. Data from current loops, widely used in applications where long cable runs and noise are concerns, can easily be captured for record keeping, alarming or diagnostics.</p>
<p class="wp-caption-text">Milliamper Data Logger</p>
<p>With a wide selection, we can provide the exact product to fit your needs depending on the number of channels required, sample rate, data storage required and other requirements of the application. A sampling of our products includes:</p>

MilliAmper – Single channel, battery   [...]]]></description>
			<content:encoded><![CDATA[<p>CAS Dataloggers has a great selection of equipment data loggers to monitor and record 4-20 mA process current signals provided by many common types of sensors and transducers. Data from current loops, widely used in applications where long cable runs and noise are concerns, can easily be captured for record keeping, alarming or diagnostics.</p>
<div id="attachment_124" class="wp-caption aligncenter" style="width: 310px"><a href="http://www.dataloggerinc.com/dataloggerinc_blog/wp-content/uploads/2010/08/automationsolutions-milliamper.jpg"><img class="size-medium wp-image-124" title="Milliamper Data Logger" src="http://www.dataloggerinc.com/dataloggerinc_blog/wp-content/uploads/2010/08/automationsolutions-milliamper-300x213.jpg" alt="milliamper data logger for 4-20 mA signals" width="300" height="213" /></a><p class="wp-caption-text">Milliamper Data Logger</p></div>
<p>With a wide selection, we can provide the exact product to fit your needs depending on the number of channels required, sample rate, data storage required and other requirements of the application. A sampling of our products includes:</p>
<ul>
<li><strong>MilliAmper</strong> – Single channel, battery      powered for remote applications with a removable memory card</li>
<li><strong>Accsense</strong> <strong>A1-10 Pod </strong>– Wireless monitoring with automatic upload and a web      interface</li>
<li><strong>Grant Squirrel</strong> <strong>SQ20xx</strong> – Portable battery operated      loggers ideal for temporary collection and trouble shooting</li>
<li><strong>Datataker DT8x</strong> – Rugged,      industrial data loggers with flexible inputs, alarms and triggering</li>
<li><strong>Delphin </strong>– High speed data loggers      for capturing transient events.</li>
</ul>
<p>For more information, visit our <strong><a href="../../categories/DC_Current_Data_Loggers/4/">DC Current Data Logger Page</a></strong> or call us at <strong>800 956-4437</strong> to discuss your needs with one of our sales engineers. We can also help you find sensors for pressure, flow, temperature or other parameters to go along with the data logger. Visit our web site <strong><a href="../../">CAS Dataloggers</a></strong> for a complete selection of data logging and recording equipment</p>
]]></content:encoded>
			<wfw:commentRss>http://www.dataloggerinc.com/dataloggerinc_blog/2010/08/process-current-data-loggers-for-4-20-ma-signals/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>New CAS Dataloggers Catalog is Now Available</title>
		<link>http://www.dataloggerinc.com/dataloggerinc_blog/2010/07/new-cas-datalogger-catalog-is-now-available/</link>
		<comments>http://www.dataloggerinc.com/dataloggerinc_blog/2010/07/new-cas-datalogger-catalog-is-now-available/#comments</comments>
		<pubDate>Fri, 23 Jul 2010 13:43:53 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[News]]></category>

		<guid isPermaLink="false">http://www.dataloggerinc.com/dataloggerinc_blog/?p=119</guid>
		<description><![CDATA[<p>Just in from the printer, the new CAS Dataloggers catalog features the latest data logging systems from leading manufacturers. The selection of data loggers includes models with 2 to more than 100 inputs that can measure temperature, humidity, voltage, current and many other parameters. They are suitable for a wide range of applications in manufacturing, research, healthcare, and environmental monitoring.</p>
<p class="wp-caption-text">CAS Dataloggers Catalog</p>
<p>Products featured in the new catalog include:</p>

Accsense – Wireless and LAN based      sensor pods with on-line monitoring
dataTaker – Multi-function,      universal input data loggers with a web interface
Grant Instruments [...]]]></description>
			<content:encoded><![CDATA[<p>Just in from the printer, the new <strong>CAS Dataloggers</strong> catalog features the latest data logging systems from leading manufacturers. The selection of data loggers includes models with 2 to more than 100 inputs that can measure temperature, humidity, voltage, current and many other parameters. They are suitable for a wide range of applications in manufacturing, research, healthcare, and environmental monitoring.</p>
<div id="attachment_120" class="wp-caption alignleft" style="width: 310px"><a href="http://www.dataloggerinc.com/dataloggerinc_blog/wp-content/uploads/2010/07/Catalog-Setup-6-4-10-Cover.jpg"><img class="size-medium wp-image-120   " style="border: 1px solid black;" title="Catalog Setup 6 4 10 Cover" src="http://www.dataloggerinc.com/dataloggerinc_blog/wp-content/uploads/2010/07/Catalog-Setup-6-4-10-Cover-300x229.jpg" alt="CAS Dataloggers Catalog" width="300" height="229" /></a><p class="wp-caption-text">CAS Dataloggers Catalog</p></div>
<p>Products featured in the new catalog include:</p>
<ul>
<li><strong>Accsense</strong> – Wireless and LAN based      sensor pods with on-line monitoring</li>
<li><strong>dataTaker</strong> – Multi-function,      universal input data loggers with a web interface</li>
<li><strong>Grant Instruments</strong> – High accuracy      portable data loggers</li>
<li><strong>Ibexis</strong> – Remote monitoring with integrated      cellular modem</li>
</ul>
<p>The selection of data loggers featured in the catalog are satisfy many different kinds of needs such as general purpose data loggers that can simultaneous acquire analog, digital, serial and Modbus data, geotechnical data loggers for monitoring bridges, dams and tunnels, temperature monitoring systems for furnaces, ovens, refrigerators, freezers and cryostats with sophisticated alarming capabilities, battery operated portable models that can be used for troubleshooting intermittent faults and monitoring systems that can collect and automatically transmit data from remote sites.</p>
<p>To get your copy, please click here for the <a href="http://www.dataloggerinc.com/contact/catalog-request.php" target="_blank">On-line Request Form</a> or call us at <strong>800-956-4437</strong>. For a great selection of all types of data loggers from more than a dozen manufacturers, visit our web site, <a href="http://www.dataloggerinc.com">www.dataloggerinc.com</a>.</p>
]]></content:encoded>
			<wfw:commentRss>http://www.dataloggerinc.com/dataloggerinc_blog/2010/07/new-cas-datalogger-catalog-is-now-available/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>CAS Dataloggers has moved</title>
		<link>http://www.dataloggerinc.com/dataloggerinc_blog/2010/07/cas-dataloggers-has-moved/</link>
		<comments>http://www.dataloggerinc.com/dataloggerinc_blog/2010/07/cas-dataloggers-has-moved/#comments</comments>
		<pubDate>Thu, 15 Jul 2010 19:31:02 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[News]]></category>

		<guid isPermaLink="false">http://www.dataloggerinc.com/dataloggerinc_blog/?p=114</guid>
		<description><![CDATA[<p>To accommodate our growth, CAS Dataloggers has relocated our offices to:</p>
12628   Chillicothe Rd.
Unit J
Chesterland,  OH 44026
<p class="wp-caption-text">New CAS Dataloggers Offices</p>
<p>Click here for: Google Map of our new location</p>
<p>This new space will allow us to serve you better with:</p>

Expanded product inventory
A new phone system with direct dial lines
Larger training area
A drive up window!

<p>Our new offices also provide room for us to add staff in the future as we take on new product lines.</p>
]]></description>
			<content:encoded><![CDATA[<p>To accommodate our growth, CAS Dataloggers has relocated our offices to:</p>
<address>12628   Chillicothe Rd.</address>
<address>Unit J</address>
<address>Chesterland,  OH 44026</address>
<div id="attachment_115" class="wp-caption alignright" style="width: 362px"><a href="http://www.dataloggerinc.com/dataloggerinc_blog/wp-content/uploads/2010/07/12628Chillicothe.jpg"><img class="size-full wp-image-115 " title="12628Chillicothe" src="http://www.dataloggerinc.com/dataloggerinc_blog/wp-content/uploads/2010/07/12628Chillicothe.jpg" alt="CAS Dataloggers new Office" width="352" height="265" /></a><p class="wp-caption-text">New CAS Dataloggers Offices</p></div>
<p>Click here for: <a href="http://maps.google.com/maps?f=q&amp;source=s_q&amp;hl=en&amp;geocode=&amp;q=12628+Chillicothe+Road,+Chesterland,+OH&amp;sll=41.525395,-&lt;/code&gt;81.337945&amp;sspn=0.010844,0.015042&amp;g=12628+Chillicothe+Road,+Chesterland,+OH&amp;ie=UTF8&amp;hq=&amp;hnear=12628+Chillicothe+Rd,+Chesterland,+Geauga,+Ohio">Google Map of our new location</a></p>
<p>This new space will allow us to serve you better with:</p>
<ul>
<li>Expanded product inventory</li>
<li>A new phone system with direct dial lines</li>
<li>Larger training area</li>
<li>A drive up window!</li>
</ul>
<p>Our new offices also provide room for us to add staff in the future as we take on new product lines.</p>
]]></content:encoded>
			<wfw:commentRss>http://www.dataloggerinc.com/dataloggerinc_blog/2010/07/cas-dataloggers-has-moved/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>New Wireless Air Quality Transmitter</title>
		<link>http://www.dataloggerinc.com/dataloggerinc_blog/2010/06/new-wireless-air-quality-transmitter/</link>
		<comments>http://www.dataloggerinc.com/dataloggerinc_blog/2010/06/new-wireless-air-quality-transmitter/#comments</comments>
		<pubDate>Thu, 17 Jun 2010 15:34:20 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[wireless data loggers]]></category>

		<guid isPermaLink="false">http://www.dataloggerinc.com/dataloggerinc_blog/?p=107</guid>
		<description><![CDATA[<p class="wp-caption-text">GD47 Air Quality Transmitter</p>
<p>The Eltek GD47 is a self contained transmitter for air quality measurements. It collects temperature, humidity and CO2 measurements and sends them wirelessly to a receiver for storage, display and alarming. The GD47 has an LCD to provide local real-time display of measured values. It uses a self calibration NDIR (infrared) sensor for accurate CO2 measurements in the range of 0-5000 ppm. The GD47 is powered by an external 12V supply with an internal NiMH back-up battery that can provide up to 100 hours of operation. The GD47 is one of more than two dozen models [...]]]></description>
			<content:encoded><![CDATA[<div id="attachment_108" class="wp-caption alignleft" style="width: 130px"><a href="http://www.dataloggerinc.com/dataloggerinc_blog/wp-content/uploads/2010/06/eltek-gd47.jpg"><img class="size-full wp-image-108" title="Eltek GD47 Air Quality Transmitter" src="http://www.dataloggerinc.com/dataloggerinc_blog/wp-content/uploads/2010/06/eltek-gd47.jpg" alt="eltek GD47 air quality transmitter for GEN II data logging systems" width="120" height="277" /></a><p class="wp-caption-text">GD47 Air Quality Transmitter</p></div>
<p>The Eltek GD47 is a self contained transmitter for air quality measurements. It collects temperature, humidity and CO2 measurements and sends them wirelessly to a receiver for storage, display and alarming. The GD47 has an LCD to provide local real-time display of measured values. It uses a self calibration NDIR (infrared) sensor for accurate CO2 measurements in the range of 0-5000 ppm. The GD47 is powered by an external 12V supply with an internal NiMH back-up battery that can provide up to 100 hours of operation. The GD47 is one of more than two dozen models of transmitters with versions for temperature, humidity, voltage, current, state/pulse, light and air pressure.</p>
<p>Measured data is transmitted via a proprietary wireless link to one of several receivers:</p>
<ul>
<li>RX250AL      – Wireless receiver with local storage for up to 250,000 readings and      alarm output</li>
<li>RC250      – Wireless receiver with serial data output for connection to a computer</li>
<li>WSR –      Wireless receiver with analog output</li>
</ul>
<p>Depending on the transmitter frequency and environment, the typical wireless range can be several hundred feet to almost a mile. Repeaters are available to extend the range.</p>
<p>For more information, visit the <strong><a href="http://www.dataloggerinc.com/eltek">Eltek Product Page</a></strong> on our web site or call us at <strong>800-956-4437</strong>. For more information on data logging products from more than a dozen manufacturers go to the <a href="http://www.dataloggerinc.com">CAS Dataloggers Web Site</a>.</p>
]]></content:encoded>
			<wfw:commentRss>http://www.dataloggerinc.com/dataloggerinc_blog/2010/06/new-wireless-air-quality-transmitter/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>CAS Dataloggers Exhibit at 2010 A&amp;WMA Show</title>
		<link>http://www.dataloggerinc.com/dataloggerinc_blog/2010/06/cas-dataloggers-exhibit-at-2010-awma-show/</link>
		<comments>http://www.dataloggerinc.com/dataloggerinc_blog/2010/06/cas-dataloggers-exhibit-at-2010-awma-show/#comments</comments>
		<pubDate>Tue, 15 Jun 2010 14:18:58 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[News]]></category>

		<guid isPermaLink="false">http://www.dataloggerinc.com/dataloggerinc_blog/?p=102</guid>
		<description><![CDATA[<p>We will be exhibiting our advanced data logging equipment from dataTaker, Ibexis and Grant Instruments  in Booth 826 at the  A&#38;WMA 103rd Annual Conference and Exhibit in Calgary, June 22-25.  If you&#8217;re there stop by, say hello to Pete and ask him to show you our latest products.</p>
]]></description>
			<content:encoded><![CDATA[<p>We will be exhibiting our advanced data logging equipment from <a href="http://www.dataloggerinc.com/manufacturers/dataTaker/1/">dataTaker</a>, <a href="http://www.dataloggerinc.com/manufacturers/Ibexis/12/">Ibexis</a> and <a href="http://www.dataloggerinc.com/manufacturers/Grant_Instruments/2/">Grant Instruments </a> in <strong>Booth 826</strong> at the  <a href="http://www.awma.org/ACE2010/">A&amp;WMA 103rd Annual Conference and Exhibit</a> in Calgary, June 22-25.  If you&#8217;re there stop by, say hello to Pete and ask him to show you our latest products.</p>
]]></content:encoded>
			<wfw:commentRss>http://www.dataloggerinc.com/dataloggerinc_blog/2010/06/cas-dataloggers-exhibit-at-2010-awma-show/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>64 Channel Thermocouple Data Logger</title>
		<link>http://www.dataloggerinc.com/dataloggerinc_blog/2010/06/64-channel-thermocouple-data-logger/</link>
		<comments>http://www.dataloggerinc.com/dataloggerinc_blog/2010/06/64-channel-thermocouple-data-logger/#comments</comments>
		<pubDate>Wed, 09 Jun 2010 17:24:25 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Temperature Data Loggers]]></category>
		<category><![CDATA[Uncategorized]]></category>

		<guid isPermaLink="false">http://www.dataloggerinc.com/dataloggerinc_blog/?p=95</guid>
		<description><![CDATA[<p class="wp-caption-text">Delphin 64KTM</p>
<p>The Delphin 64KTM was developed to provide a multi-channel solution for temperature measurement using thermocouples. It provides 64 differential inputs with 110V isolation and galvanic separation prevent measurement errors from ground loops and a 24 bit sigma-delta A/D converter. The Cold Junction reference temperature is measured using a class A, 4-wire RTD enabling an absolute accuracy of 0.2°.</p>
<p>Typical users are R&#38;D groups and laboratories who need to acquire highly precise temperature measurements. Traditional areas of use are test stations for gas turbines or boilers but the system is also suitable for temperature measurement in ovens, furnaces, heating chambers, [...]]]></description>
			<content:encoded><![CDATA[<div id="attachment_96" class="wp-caption alignleft" style="width: 310px"><a href="http://www.dataloggerinc.com/dataloggerinc_blog/wp-content/uploads/2010/06/delphin_64ktm.jpg"><img class="size-full wp-image-96" title="delphin_64ktm" src="http://www.dataloggerinc.com/dataloggerinc_blog/wp-content/uploads/2010/06/delphin_64ktm.jpg" alt="Delphin 64KTM Thermocouple data logger" width="300" height="200" /></a><p class="wp-caption-text">Delphin 64KTM</p></div>
<p>The Delphin 64KTM was developed to provide a multi-channel solution for temperature measurement using thermocouples. It provides 64 differential inputs with 110V isolation and galvanic separation prevent measurement errors from ground loops and a 24 bit sigma-delta A/D converter. The Cold Junction reference temperature is measured using a class A, 4-wire RTD enabling an absolute accuracy of 0.2°.</p>
<p>Typical users are R&amp;D groups and laboratories who need to acquire highly precise temperature measurements. Traditional areas of use are test stations for gas turbines or boilers but the system is also suitable for temperature measurement in ovens, furnaces, heating chambers, temperature controlled enclosures and manufacturing or processing equipment.</p>
<p>The 64KTM is equipped with internal memory for up to 128 million data records. The memory&#8217;s independent data recording capability provides data security for long-term measurement runs. Individual channels can be set up with limit values enabling monitoring and alarm functions and calculations including moving averages. The basis version if the 64KTM is set up for 64 channel operation and the modular design enables several units to be connected so that several thousand channels can be processed.</p>
<p>Other features include:<br />
•	Industrial grade 19&#8243; rack enclosure<br />
•	Support for E,J,K,L,N,S,R,T,U thermocouples<br />
•	24 Bit measurement resolution<br />
•	1 GB Internal memory<br />
•	Ethernet, Modbus, Profibus interfaces<br />
•	Up to 1 GB of local memory<br />
•	Expandable to &gt;1000 channels</p>
<p>For more information, go to the <a href="http://www.dataloggerinc.com/products/Delphin_64_KTM_Temperature_Measurement_System/142/">64KTM Product Page</a> or call us at 1-800-956-4437. To find out about all of the data logging products we offer including models from more than a dozen manufacturers, visit our web site <a href="http://www.dataloggerinc.com">www.DataLoggerInc.com</a>.</p>
]]></content:encoded>
			<wfw:commentRss>http://www.dataloggerinc.com/dataloggerinc_blog/2010/06/64-channel-thermocouple-data-logger/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>New Video Tutorials</title>
		<link>http://www.dataloggerinc.com/dataloggerinc_blog/2010/06/new-video-tutorials/</link>
		<comments>http://www.dataloggerinc.com/dataloggerinc_blog/2010/06/new-video-tutorials/#comments</comments>
		<pubDate>Thu, 03 Jun 2010 19:24:45 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Tutorial Page]]></category>
		<category><![CDATA[Tutorial Page Updates]]></category>

		<guid isPermaLink="false">http://www.dataloggerinc.com/dataloggerinc_blog/?p=81</guid>
		<description><![CDATA[<p>We have just added 2 new video&#8217;s to our Tutorial Web Page:</p>
<p>Installing and Using Grant SquirrelView Software</p>
<p>Programming dataTaker Data Loggers for use with SDI-12 Devices</p>
]]></description>
			<content:encoded><![CDATA[<p>We have just added 2 new video&#8217;s to our <a title="CAS Datalogger Tutorial Page" href="http://www.dataloggerinc.com/tutorials/" target="_self">Tutorial Web Page</a>:</p>
<p><a title="Installing and Using SquirrelView" href="http://www.dataloggerinc.com/videos/InstallingandusingSquirrelview.wmv" target="_blank">Installing and Using Grant SquirrelView Software</a></p>
<p><a title="Interfacing SDI-12 Devices with dataTaker Data Logges" href="http://www.dataloggerinc.com/videos/SDI12_Flash/SDI12.php" target="_blank">Programming dataTaker Data Loggers for use with SDI-12 Devices</a></p>
]]></content:encoded>
			<wfw:commentRss>http://www.dataloggerinc.com/dataloggerinc_blog/2010/06/new-video-tutorials/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>New RTR-500 Series Wireless Data Loggers with Cellular Base Station</title>
		<link>http://www.dataloggerinc.com/dataloggerinc_blog/2010/05/new-rtr-500-series-wireless-data-loggers-with-cellular-base-station/</link>
		<comments>http://www.dataloggerinc.com/dataloggerinc_blog/2010/05/new-rtr-500-series-wireless-data-loggers-with-cellular-base-station/#comments</comments>
		<pubDate>Thu, 27 May 2010 12:55:17 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Humidity data loggers]]></category>
		<category><![CDATA[New  Temperature Data Loggers]]></category>
		<category><![CDATA[Temperature Data Loggers]]></category>

		<guid isPermaLink="false">http://www.dataloggerinc.com/dataloggerinc_blog/?p=77</guid>
		<description><![CDATA[<p>CAS Dataloggers is pleased to announce the new RTR-500 family of wireless data loggers from TandD Corporation of Japan. These data loggers give you the ability to monitor temperature and humidity virtually anywhere via a built in GSM/GPRS Cellular Modem in the RTR-500GSM base station.  The individual loggers communicate with the base station via a high speed short range 900 MHz wireless network. Then, data and alarms are automatically sent from the base station via email or ftp via the standard cell phone network.</p>
<p>The RTR-500 family currently includes:</p>

RTR-500 USB Base Station/Repeater
RTR-500GSM Base Station with      GSM/GPRS [...]]]></description>
			<content:encoded><![CDATA[<p><strong><a href="http://www.dataloggerinc.com/dataloggerinc_blog/wp-content/uploads/2010/05/tandd_rtr-500gsm_web.jpg"><img class="alignleft size-medium wp-image-78" title="tandd_rtr-500gsm_web" src="http://www.dataloggerinc.com/dataloggerinc_blog/wp-content/uploads/2010/05/tandd_rtr-500gsm_web-150x300.jpg" alt="" width="150" height="300" /></a>CAS Dataloggers</strong> is pleased to announce the new <strong>RTR-500</strong> family of wireless data loggers from TandD Corporation of Japan. These data loggers give you the ability to monitor temperature and humidity virtually anywhere via a built in <strong>GSM/GPRS Cellular Modem</strong> in the <strong>RTR-500GSM</strong> base station.  The individual loggers communicate with the base station via a high speed short range 900 MHz wireless network. Then, data and alarms are automatically sent from the base station via email or ftp via the standard cell phone network.</p>
<p>The <strong>RTR-500</strong> family currently includes:</p>
<ul>
<li><strong>RTR-500</strong> USB Base Station/Repeater</li>
<li><strong>RTR-500GSM</strong> Base Station with      GSM/GPRS modem</li>
<li><strong>RTR-501</strong> Temperature Data Logger      with internal sensor</li>
<li><strong>RTR-502</strong> Temperature Data Logger      with external sensor</li>
<li><strong>RTR-503</strong> Temperature and Humidity      Data Logger</li>
</ul>
<p>They offer improved performance over the current RTR-5 series including increased short range wireless range (up to 500 feet), faster download speed and longer battery life, (up to 4 years in the high capacity models).</p>
<p>The new <strong>RTR-500GSM</strong> Cellular Base Station is the heart of the system. It can automatically download data from up to 20 individual data loggers. The base station also provides real-time monitoring of the data loggers for alarm conditions and can then send the alarm notification via email or SMS. The <strong>RTR-500GSM</strong> can be powered from an external 8-34 VDC source and features an internal battery backup. It also provides a set of alarm contacts for local notification. An optional GPS can be attached to the <strong>RTR-500GSM</strong> for location tracking. A new software set-up wizard simplifies the GSM network configuration of the base station.</p>
<p>The <strong>RTR-500</strong> family is ideal for monitoring temperature and humidity in locations where LAN connections are not available or practical such as trucks transporting perishable goods, remote storage or warehouse locations and environmental monitoring.</p>
<p>For more information, visit the <strong><a href="../../manufacturers/TandD/19/">TandD Product Page</a></strong>, click here for the <strong><a href="../../datasheets/tandd_rtr500.pdf">RTR-500 Brochure</a></strong>, call us at <strong>800-956-4437</strong> or fill out this form:</p>
[contact-form]
]]></content:encoded>
			<wfw:commentRss>http://www.dataloggerinc.com/dataloggerinc_blog/2010/05/new-rtr-500-series-wireless-data-loggers-with-cellular-base-station/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>New DC High Voltage Data Logger</title>
		<link>http://www.dataloggerinc.com/dataloggerinc_blog/2010/05/new-dc-high-voltage-data-logger/</link>
		<comments>http://www.dataloggerinc.com/dataloggerinc_blog/2010/05/new-dc-high-voltage-data-logger/#comments</comments>
		<pubDate>Wed, 19 May 2010 14:48:40 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[DC Voltage Data Loggers]]></category>
		<category><![CDATA[AEMC Data Loggers]]></category>

		<guid isPermaLink="false">http://www.dataloggerinc.com/dataloggerinc_blog/?p=73</guid>
		<description><![CDATA[<p class="wp-caption-text">L481 DC High Voltage Data Loggers</p>
<p>We are pleased to introduce the new Simple Logger® II model L481 DC Voltage Data Logger. It provides an extended voltage measurement range of ±850 VDC with a resolution of 0.1V making is suitable for applications such as monitoring rail voltages, machines, windmills, power supplies and battery packs and for finding intermittent voltage problems.</p>
<p>The L481 can be programmed to sample from 8 times per second to once a day. It can store up to 240,000 measurements in internal non-volatile memory and offers 3 recording modes including Extended Recording Mode (XRM®) for long term data [...]]]></description>
			<content:encoded><![CDATA[<div id="attachment_75" class="wp-caption alignleft" style="width: 202px"><a href="http://www.dataloggerinc.com/dataloggerinc_blog/wp-content/uploads/2010/05/aemc_l4811.jpg"><img class="size-medium wp-image-75  " title="aemc_l481" src="http://www.dataloggerinc.com/dataloggerinc_blog/wp-content/uploads/2010/05/aemc_l4811-300x253.jpg" alt="L481 DC high voltage data logger" width="192" height="162" /></a><p class="wp-caption-text">L481 DC High Voltage Data Loggers</p></div>
<p>We are pleased to introduce the new Simple Logger<sup>®</sup> II model <strong>L481 DC Voltage Data Logger</strong>. It provides an extended voltage measurement range of <strong>±850 VDC</strong> with a <strong>resolution of 0.1V</strong> making is suitable for applications such as monitoring rail voltages, machines, windmills, power supplies and battery packs and for finding intermittent voltage problems.</p>
<p>The <strong>L481</strong> can be programmed to sample from 8 times per second to once a day. It can store up to <strong>240,000 measurements</strong> in internal non-volatile memory and offers 3 recording modes including Extended Recording Mode (XRM<sup>®</sup>) for long term data collection. The L481 is <strong>battery powered</strong> and can operate up to 45 days on 2x AA cells. A simple LED display on the front of the logger provides an immediate indication of logging status and memory usage. Voltage inputs are via standard recessed banana jacks and a set of 5 foot cables with alligator clips are included with the logger.</p>
<p>For set-up and download of data, the <strong>L481</strong> logger has a <strong>USB 2.0</strong> interface for connection to a standard Windows PC. The free <strong>DataView</strong><strong><sup>®</sup> software</strong> included with the unit provides a very simple way to configure the logger, view real-time data, download and plot stored data and generate standard or custom reports. It also allows the measured data to be scaled to custom engineering units and can synchronize multiple loggers to record at the same time.</p>
<p>For more information on the <strong>L481 Voltage Data Logger</strong>, visit the <strong><a href="../../manufacturers/AEMC/11/">AEMC Product Page</a></strong> or call us at <strong>800 956-4437</strong>. To view a complete selection of data logger for all types of applications, visit our web site, <strong><a href="../../">www.DataLoggerInc.com</a></strong>.</p>