A full range of voltage and current data loggers fully equipped to handle a large variety of recording applications. The Electrocorder family includes loggers with one to three channels for current and/or voltage in single phase and three phase AC models and DC input versions all in a variety of recording ranges. Electrocorder systems are supplied with all necessary connection leads, software and communication cables.
|
DC-3V-60
- Three Channel: 60Vdc (D1, D2 & D3 to Common)
- Monitor charging circuits, PV (photovoltaic) cell, DC motor,
and many other application.
- Accurately record DC voltages up to 60Vdc.
- Records VAvg, VMax & VMin on all 3 channels. Data is stored in
non-volatile memory.
- Optional DC current transducers available.
|
|
|
EC-1A
- Single channel (A1), various ranges, 4A to 10kA
- Enables current and load problems to be highlighted for
further investigation.
- Allows users to record load currents up to 10kAac, range is
model dependent.
- One input channel, A1.
- Record IAvg, IMax & IMin. Data stored in non-volatile memory.
- Recorded data is uploaded to a PC for analysis with
Electrosoft.
|
|
|
EC-3A
- Three phase; 400A, 1kA, 2kA or 3kAac
- Enables current and load problems to be highlighted for
further investigation
- Allows users to record load currents up to 3kAac, range is
model dependent.
- Three current input channels (A1, A2, & A3).
- Records Max, Min and Avg current on all 3 channels.
|
|
|
EC-3CT
- Three phase; 30Aac, 60Aac or 300Aac (300A max input)
- Enables current or load problems to be highlighted
and investigated.
- Allows users to accurately record load currents up
to 300Aac.
- Three current input channels (A1, A2, & A3).
- Records IAvg, IMax & IMin on all 3 channels. Data stored in nonvolatile
memory.
|
|
|
SR-1R
- Single channel, 0-1500W/m-2, model dependent.
- Enables users to conduct site or installation surveys.
- Records Solar Irradiance up to 1500W/m-2.
- One input channel.
- Records minimum, average and maximum solar Irradiance.
- Recorded data is uploaded to a PC for analysis
with Electrosoft.
|
|
|
CT-1A
- Single channel current, 0.1A to 100A
- Enables users to record current and energy data.
- Records load currents up to 100Aac, range is
model dependent.
- One input channel, A1.
- Kit includes Logger, current transformer, Serial Lead, software,
& Plug in mains 12Vdc PSU.
|
|
|
LS-1V
- Single Phase 300Vac (Live/Hot to Neutral)
- Records the date and times of loss and regain of mains
voltage supply.
- Allows engineers to quickly and cost effectively monitor
supply interruptions.
- Small, safe & easy to use, waterproof to IP65!
- User set-able voltage threshold which defines the loss of
supply, e.g. loss can be user set as voltages below 100V.
|
|
|
EC-1V
- Single Phase 300Vac (Live/Hot to Neutral)
- Voltage recorder enables real voltage problems to be high
lighted quickly for further investigation
- Allow engineers to quickly and cost effectively monitor & re
solve possible supply problems
- Small, safe & easy to use
- Electrosoft includes internal database to ensure effective
management of distributed units
- Selectable measurement resolution to suit each situation,
accurate to ±1% of reading + 1 Volt (90 - 260Vac)
|
|
|
EC-2V
- Two Phase 300Vac, 2 channels, Live to Neutral & Earth/Ground to Neutral
- React to domestic voltage complaints within 24 hours -
maximum service!
- Store Electrocorders in your field engineer’s vehicles, radio
through complaints for instant delivery.
- Miniature logger enables real voltage problems to be high
lighted quickly for further investigation.
- Free-up expensive inventory which would otherwise be used for
domestic complaints.
|
|
|
EC-3V
- Three phase; 500Vac (L1, L2 & L3 to Neutral) with phase rotation checker
- Enables voltage problems to be highlighted quickly for
further investigation
- Allows engineers to quickly and cost effectively monitor &
resolve single & 3-phase voltage problems
- Three phase input (L1, L2, & L3) & Neutral (N). Use for single
phase logging also!
- Integral Phase Sequence or Rotation Checker
|
|
|
SL-3V
- Three phase; 500Vac (L1, L2 & L3 to Neutral)
- Small size 145x89x46mm, enables voltage problems to be
highlighted quickly for further investigation.
- Allows engineers to quickly and cost effectively monitor &
resolve single & 3-phase voltage problems.
- Three phase inputs (L1, L2, & L3) & Neutral (N). Use also for
single phase logging also!
- Selectable averaging period to suit each situation, accurate to
±2% of reading.
- Memory capacity of 32,000 (true RMS) values per channel
(10bit), up to 300 days continuous recording.
|
|
|
CT-2VA
- One voltage channel 300Vac
- One current channel 30Aac or 60Aac
- Enables voltage and load problems to be highlighted for
further investigation.
- Allows users to monitor & resolve single-phase voltage
and current issues.
|
|
|
PV-3
- Records Solar Irradiance, 0-1500W/m-2
- PV system output Vdc to 300V, Idc to 100A
- Monitor charging circuits, PV (photovoltaic) cell, DC motor,
and many other application.
- Accurately record DC voltages up to 60Vdc.
- Kit includes logger, fused voltage input leads, DC
current probe, pyranometer, USB lead, 12Vdc PSU,
software and carry case.
|
|
|
AL-2VA
- Allows users to record energy consumption up to 300V, 16A
- One Voltage input lead, one output lead
- Internal current sensor
- Records VAvg, VMax, & VMin and IAvg, IMax & IMin
- Recorded data is uploaded to a PC for analysis with
Free Electrosoft Software.
- Memory capacity of 32,000 true RMS voltage values per phase
(10 bit), up to 300 days continuous recording.
|
|
|
DC-3VA
- 2 Channels Voltage (300V), 1 Channel Current +/-10A or +/-100A
- Records DC voltage and current
- Monitor charging circuits, PV (photovoltaic) cell, DC motor,
and many other application.
- Accurately record DC voltages and DC current.
- Records VAvg, VMax & VMin on 2 channels, Iavg, Imax & Imin
on 1 channel.
- Recorded data is uploaded to a PC for analysis
with Free Electrosoft Software.
- Selectable averaging period to suit each situation, accurate
to <1% of range.
|
|
|
EC-2VA
- One voltage channel 300Vac, One current channel 500Aac
- Enables voltage and load problems to be highlighted for
further investigation.
- Allows users to monitor & resolve single-phase voltage
and current issues.
- One Voltage input (L1), one Current input (A1).
- Voltage channels record VAvg, VMax & VMin.
- Recorded data is uploaded via RS-232 to a PC for analysis
with Free Electrosoft Software.
- Memory capacity of 32,000 (true RMS) values per channel
(10bit), up to 300 days continuous recording.
|
|
|
EC-7VAR
- Three voltage channels 500Vac, Three current channels 400A, 1kA, 2kA or 3kAac.
- Records voltage, current, power factor, power and energy.
- Records voltage up to 500Vac & loads up to 3kAac,
model dependent.
- Three voltage input channels (L1, L2, & L3), 0-500V &
Neutral(N).
- Voltage channels record VAvg, VMax & VMin on all 3 channels.
Data stored in non-volatile memory.
- Three current channels (A1, A2 & A3) 400A, 1kA, 2kA & 3kA
model dependent.
- Memory capacity of 32,000 (true RMS) values per channel
(10bit), up to 300 days continuous recording.
|
|