Request Pricing & Information
LogMessage Data Acquisition Systems
Stand alone operation
LogMessage is a stand alone operating device for acquiring, monitoring, calculating and logging measurement data. It is equipped with a 3.5GB memory for logging up to
250 million measurement values.
Universal applications
The LogMessage's analog inputs are differentially and
galavanically isolated from each other as well as from the
power supply. Earth loops and non-isolated sensors therefore present no problem. All analog inputs can be used
universally and are capable of measuring any type of thermocouple, RTD, voltage or current signal. Channel configuration takes place via the easy to use DataService
Configurator software included with the delivery.
Various interfaces
Once configured, LogMessage can operate stand alone
and requires no PC support. Configuration and data readout takes place via a network interface. LogMessage's two
serial ports enable connection of a modem for remote
access, or for other hardware to be connected for data
transfer purposes. Alarm notifications and text messages
may also be transmitted using a GSM modem. By operating
the LogMessage device within a network, measurement
data can be transmitted online and processed using the
ProfiSignal Go software.
A complete system including software
LogMessage devices are supplied with the powerful
ProfiSignal Go software. ProfiSignal Go is a professional
PC software for the online and offline monitoring and
analysis of measurement data. If you already use other
measurement technology software, the full service package
includes LabVIEW™ and DASYLab™ drivers, Modbus TCP
and OPC Server.
|
LM1000
The LogMessage 1000 is equipped with 15 analog inputs
and a sampling rate of up to 600 measurements per
second. The inputs can be used for data acquisition of
mV, mA signals or any type of thermocouple. All inputs
have differential and galvanic isolation.
- 600 Hz sampling rate
- Analog inputs(mV, mA, thermocouple): 15
- Analog inputs(mV, mA, thermocouple, RTD): none
- Analog outputs(mA): none
- Digital inputs(counter): none
- Digital outputs: none
|
|
|
LM2000
The LogMessage 2000 is equipped with 10 universal analog
inputs, one analog output, 12 digital inputs (11 counters)
and 17 digital outputs. The device has a range of internal
monitoring and control functions that enable it to be used
as a data acquisition device as well as an independently
operating system for control, automation or monitoring.
- 600 Hz sampling rate
- Analog inputs(mV, mA, thermocouple): none
- Analog inputs(mV, mA, thermocouple, RTD): 10
- Analog outputs(mA): 1
- Digital inputs(counter): 12(11)
- Digital outputs: 17
|
|
|
LM3000
The LogMessage 3000 is equipped with 15 analog inputs
(600 Hz sampling rate) and 24 synchronous digital inputs
(with a time resolution of 1 msec). The device is highly
suited to fault analysis as well as to processing digital and analog
events.
- 600 Hz sampling rate
- Analog inputs(mV, mA, thermocouple): 15
- Analog inputs(mV, mA, thermocouple, RTD): none
- Analog outputs(mA): none
- Digital inputs(counter): 24
- Digital outputs: 1
|
|
|
LM4000
The LogMessage 4000 has an overall sampling rate of up to 10,000 measurements per second and is ideally suited to monitoring functions. Any number of alarm and logic channels can be defined for the 8 analog inputs and 28 digital channels. Any of the 5 digital outputs can be switched irrespective of the current alarm situation.
- 10000 Hz sampling rate
- Analog inputs(mV, mA, thermocouple): 8
- Analog inputs(mV, mA, thermocouple, RTD): none
- Analog outputs(mA): 2
- Digital inputs(counter):28 (2)
- Digital outputs: 5
|
|
|
LM5000
The LogMessage 5000 is equipped with 16 universal analog inputs. The inputs are designed to cope with high voltages between individual channels. The LogMessage 5000 has no problem measuring non-isolated signals.
- 80 Hz sampling rate
- Analog inputs(mV, mA, thermocouple): none
- Analog inputs(mV, mA, thermocouple, RTD): 16
- Analog outputs(mA): none
- Digital inputs(counter): none
- Digital outputs: none
|
|
|
LM6000
The LogMessage 6000 is equipped with more than 25 analog inputs. The device has an overall sampling rate of up to 1200 measurements per second and can directly acquire, monitor and record data from any thermocouple or RTD sensor.
- 1200 Hz sampling rate
- Analog inputs(mV, mA, thermocouple): 15
- Analog inputs(mV, mA, thermocouple, RTD): 10
- Analog outputs(mA): 1
- Digital inputs(counter): none
- Digital outputs: 1
|
|
|
LM7000
The LogMessage 7000 can acquire measurements from up to 30 thermocouples of any type. Configuration software is available to set channels to specific thermocouple types.
- 1200 Hz sampling rate
- Analog inputs(mV, mA, thermocouple): 30
- Analog inputs(mV, mA, thermocouple, RTD): none
- Analog outputs(mA): none
- Digital inputs(counter): none
- Digital outputs: none
|
|
|
LM8000
The LogMessage 8000 is equipped with 15 analog inputs and 12 synchronous digital inputs. The device also has 16 digital outputs to control alarms and events.
- 600 Hz sampling rate
- Analog inputs(mV, mA, thermocouple): 15
- Analog inputs(mV, mA, thermocouple, RTD): none
- Analog outputs(mA): none
- Digital inputs(counter): 12 (11)
- Digital outputs: 16
|
|
|
LM9000
The LogMessage 9000 is equipped with 20 analog inputs, 2 analog outputs and 2 digital outputs. The device has an overall sampling rate of up to 1200 measurements per second and can directly acquire, monitor and record data from any thermocouple or RTD sensor.
- 1200 Hz sampling rate
- Analog inputs(mV, mA, thermocouple): none
- Analog inputs(mV, mA, thermocouple, RTD): 20
- Analog outputs(mA): 2
- Digital inputs(counter): none
- Digital outputs: 2
|
|
Request Pricing & Information
If you need information right away or prefer to speak with a person, call us and one of our Experienced Applications Engineers will be happy to talk with you. You can reach us at 1-800-956-4437 during our normal business hours Monday - Thursday from 8am to 5:30pm and Friday from 8am to 4:30pm (EST).
After filling out the form below, an applications engineer will contact you within at least one business day. Fields that are not required are recommended to be filled out so that we can better assist you.