Data Loggers and Data Acquisition Systems For All Applications - Temperature data loggers, Voltage and Current data loggers, Humidity data loggers, Power and energy data loggers and more
Data Loggers for All Applications
1 - 800 - 956 - 4437
M-Th  8A-5:00P (EST)
Fri     8A-4:30P (EST)
Find a data logger by selecting an application from the list below.
Request Pricing & Information
Home -> VersaLog

VersaLog

Image of VersaLog 8 Channel data logger with Alarm notification and Siteview software

8 Channel Data Loggers with Alarm Notification

Accsense VersaLog dataloggers are a powerful low-cost solution for data recording applications that also require a local alarm notification. These stand alone recorders commonly feature 7-8 channels with models to log temperature, humidity, current or voltage. Two programmable alarm outputs can be configured with low or high limits to activate a relay, switch on a light or audible alarm or signal a PLC or other device. All VersaLog data loggers have a built in USB port for connection to a PC for configuration and downloading data plus an auxiliary serial port and 4-Megabytes of memory for storing up to 2 million measurements. An optional USB device server allows multiple VersaLog loggers to be connected to a single Ethernet port allowing remote, network access.

The SiteView software is compatible with Windows XP, Vista or Windows 7, 8 and can be used to configure the data loggers, retrieve stored data, graph the measurements and save or export the data. It also offers the ability to view real-time data from any connected loggers, a powerful calibration tool to convert the raw sensor output to physical parameters using either a simple linear fit or a more complex equation and a alarm management tool to allow local notification or an email notification of an alarm condition in a connected logger.



VersaLog TC Temperature Data Logger

TC

VersaLog TC Temperature Data Logger


  • 16-bit analog-to-digital converter
  • 4 MB Memory stores up to 2 million measurements
  • One on-board thermistor channel monitors ambient temperature.
  • Seven range programmable thermocouple voltage input channels cover wide measurement requirements.
  • Thermocouple: Type E, N, J, K, T
  • Can be accessed via USB, MODEM, or Ethernet connections
  • 10-year battery life
  • Fast sampling mode
  • Alarm and excitation output





VersaLog TH Thermistor Data Logger

TH

VersaLog TH Thermistor Data Logger


  • The 16-bit analog-to-digital converter meets most high-resolution requirements.
  • The 4-Mega-Byte Memory stores up to 2 million measurements.
  • One on-board thermistor channel monitors ambient temperature. Seven 10K thermistor input channels cover wide measurement requirements.
  • Can be accessed via USB, MODEM, or Ethernet connections with auto baud rate of up to 115 kbps.
  • 10-year battery life
  • Fast sampling mode
  • Alarm and excitation output





VersaLog DCV-2 Data Logger

DCV-2

VersaLog DCV-2 Voltage Data Logger


  • 16-bit analog-to-digital converter
  • 4 MB memory size
  • Both USB and serial interfaces with auto baud rate of up to 115 kbps
  • Programmable input ranges (-5 VDC to 20 VDC)
  • Over 10 years of battery Life
  • Powerful software for configuration, downloading, plotting, analysis and alarm reporting
  • Configurable Alarm Control/Excitation Controls
  • Wide sampling interval selections (20 milliseconds to 12 hours)





VersaLog DCVC-HR Voltage Current Data Logger

DCVC-HR

VersaLog DCVC-HR Voltage Current Data Logger


  • 16-bit analog-to-digital converter
  • 4 MB Memory stores up to 2 million measurements
  • Seven range programmable voltage and current external input channels
  • Can be accessed via USB, MODEM, or Ethernet connections
  • 10-year battery life
  • Fast sampling mode
  • Alarm and excitation output





VersaLog DCC-HR Current Data Logger

DCC-HR

VersaLog DCC-HR Current Data Logger


  • 16-bit analog-to-digital converter
  • 4 MB Memory stores up to 2 million measurements
  • One on-board thermistor channel monitors ambient temperature
  • Input current signals can be from sensors, transducers, transmitters or other common current sources
  • The Site-Log data loggers can be accessed via USB, MODEM, or Ethernet connections
  • 10-year battery life
  • Fast sampling mode
  • Alarm and excitation output





VersaLog DSS-1 USB Server

DSS-1

VersaLog Site USB Device Server


  • Remote Access - Communicate with data logger from anywhere Ethernet/Internet is available
  • Multiple Access - Up to 20 clients simultaneously
  • Multiple Data Loggers - Up to 25 data loggers can be connected to one Site USB Device Server
  • Password Protection for Security
  • Dynamic IP Addressing - No need to assign IP address manually
  • Power Source to Data Logger - The USB ports supply +5VDC to the data logger





VersaLog Pulse Event State Data Logger

P

VersaLog Pulse Data Logger


  • The 4-Mega-Byte Memory stores up to 2 million measurements.
  • Seven range programmable input channels for pulse count, on/off state or event timestamp measurements
  • Can be accessed via USB, MODEM, or Ethernet connections with auto baud rate of up to 115 kbps
  • 5-year battery life
  • Fast sampling mode
  • Alarm and excitation output





VersaLog BR Strain Gauge Bridge Data Logger

BR

VersaLog BR Strain Gauge Bridge Data Logger


  • The 16-bit analog-to-digital converter meets most high-resolution requirements
  • The 4-Mega-Byte Memory stores up to 2 million measurements
  • 2.5V excitation with compensation
  • 8 mV input range
  • Can be accessed via USB, MODEM, or Ethernet connections with auto baud rate of up to 115 kbps
  • 10-year battery life
  • Fast sampling mode
  • Alarm and excitation output





VersaLog Siteview Software

SiteView

VersaLog Siteview Software


  • Supports USB, Serial port and Ethernet connections for easy local and remote access
  • Fast communication speed up to 115200 bps makes downloading fast
  • Real-time view and chart recording replaces chart recording device
  • Custom equation and custom-line equation solves scientific and laboratory algorithm difficulties
  • Zoom in/zoom out, annotation/label of graph functions provide detailed view of data
  • Multiple file loading allows easy data comparison.
  • Dynamic statistics provides detailed information of current zoomed view





Related Application Notes

Below features our collection of application notes and case studies related to this page.

Data Loggers Monitor & Alarm a Medical R&D Lab

Environmental Monitoring in a Manufacturing Plant

Monitoring and Alarming Failing AC Compressors

Proving Best Practices in Fruit and Vegetable Transport

Temperature Monitoring and Alarming in Meat Lockers

View all related application notes



Request Pricing & Information

If you need information right away or prefer to speak with a person, call us and one of our Experienced Applications Engineers will be happy to talk with you. You can reach us at 1-800-956-4437 during our normal business hours Monday - Thursday from 8am to 5:30pm and Friday from 8am to 4:30pm (EST).

After filling out the form below, an applications engineer will contact you within at least one business day. Fields that are not required are recommended to be filled out so that we can better assist you.

Request Form

Submit the product or application you are interested in and we'll contact you. Need immediate information? Give us a call at 800-956-4437.

Name (required):
Email (required):
Company:
Phone #:
City:
State:
Country:
Product(s) of Interest:
Application:
Additional Information:
Human Verification What is the next number after 8?  

**Your contact information allows us to provide you with pricing information. We never sell or distribute your information. See our Policies page for more information.


Follow CAS Dataloggers on Facebook Follow us on LinkedIn Follow us on Twitter Find us on Google+ Find us on Youtube
Home | About CAS | Policies | Distributor Login | Systems Integrators