Data Loggers For All Applications
Data Loggers for All Applications
1 - 800 - 956 - 4437
M-Th 8A-5:30P(EDT)
Fri     8A-4:30P(EDT)
Find a data logger by selecting an application from the list below.
Request Pricing & Information
Home -> Accsense -> A1-01a Wireless Environmental Data Logger

A1-01a Wireless Environmental Data Logger

Accsense A1-01a Environmental Measurement Pod

Product Overview
  • Internal temperature, humidity, light and vibration sensors
  • External 4-20mA and 0-5V inputs
  • 2 Digital inputs
  • Battery or AC power
  • Up to 250' range
  • 250 Sample data buffer

The A1-01a Pod requires a B1-06 Gateway

Useful Links
Accsense A1-01a Environmental Measurement Pod


Manufacturer - Accsense

Model Number - A1-01a

Product Spec Sheet

General Purpose Pod

The A1-01a General Purpose Sensor Pod is designed for general environmental measurements. It provides several different internal sensors, as well as a screw terminal connector for connecting to a wide range of external analog sensors. The pod also includes a +5Vdc output to power external sensors.

In the event no gateway can be reached, individual pods will store up to 255 data points, until a connection is restored. Pods have a range of approx. 80m (250ft), and can also act as a repeater for other's signals.

Package Includes
  • A1-01 Pod
  • Pin-out Guide
  • AC Adapter
  • Standard Antenna
  • Wall Mounting Bracket
  • Batteries (3xAA)
Internal Sensors
  • Ambient Temperature
  • Vibration
  • Humidity
  • Acoustic Level
  • Ambient Light
External Sensor Inputs:
  • 4-20mA Current Input with +20Vdc Loop
  • Digital Input (Contact Closure)
  • Counter
  • 0-5Vdc Analog Input with +5Vdc Sensor Drive

Real-time Monitoring & Alarming

All of the measurements acquired using the Accsense Solution are immediately available on your secure Accsense Account, online. Each gateway requires an online account subscription. Updated in real-time, you can plot measurement history, analyze tabular data, and set alarms to watch your data and provide email, pager, or cell phone alerts. See the Online Account in action by trying out our Live Demo.

Features:
  • Simple to use, virtually no learning curve
  • Web based, no software installation or firewall configuration hassles
  • Customizable interface with dashboard of most recent measurements from all sensor pods
  • Instant access to charts depicting measurement history, with ranges as narrow as 5 minutes or as wide as 90 days.
  • Manual vertical scaling allows for consistency across multiple graphs and samples.
  • Setup alarm states and receive alarms via email, cell phone, pager, or landline. Even send the same alarm to multiple locations!
  • View tabular measurement data online
  • Download measurement data for offline analysis
  • Allow password-protected, limited access to certain users
  • Completely secure and backed up at Rackspace™
  • FREE software/feature upgrades!

The service exists at three levels. The table below will help you decide which service level is right for you. Remember, you can upgrade your service at anytime.

E1-16 External Battery Pack
  • Plugs into All Wireless Pods In Place Of AC Adaptor
  • Extends Battery Life To 2-3 Years
  • Batteries Not Included
E1-33 CO2 Sensor
  • 0% - 10%
  • 0-5V/4-20mA Output
  • Accuracy at 25°C ±0.2%
  • Includes Remote Sensor, Probe & 6' Cable
  • Requires external power
E1-36 Pressure Sensor
  • ±1.5 W.C
  • 4-20mA OUTPUT
  • Temperature Limits: 18° TO 60 °C
  • Accuracy: ±0.25% F.S.
  • Screw Type Terminal Block
  • Requires external power
E1-38 Oxygen Deficiency Monitor
  • RANGE 0-25%
  • 95db Audible Alarm
  • 4-20mA Output
  • LED Display & Battery Backup
  • 2 Oxygen Alarms
  • Requires external power
You can download the specifications in PDF format. Download

Internal Sensors

Ambient Temperature Sensor
Temperature Range -40°C to +70°C
Typical Accuracy at 25°C ±0.3°C
Typical Accuracy over Full range ±1.4% full Span
Measurement Resolution :0.01°C
Vibration (Relative figures, Uncalibrated)
Number of Axis (averaged together) 3
Maximum Acceleration, each axis ±2G
Offset and Sensitivity Error ±10%
Measurement Resolution 0.006G
Relative Humidity
Humidity Range 5% to 95%rh
Humidity Accuracy at 25°C ±2%rh
Humidity Accuracy over Full Range ±3%rh
Measurement Resolution 0.03%rh
Acoustic Level (Relative figures, Uncalibrated)
Range 0% to 100%
Resolution 0.1%
Visible Light (Relative figures, Uncalibrated)
Range (logarithmic) 0-64000 Lux
Resolution 200 pts/Decade

External Inputs

Analog Voltage Input with 5Vdc Output
Voltage Range 0 to 5Vdc
Typical Accuracy ±0.28% full scale
Measurement Resolution 4.883 mV
Input Impedance >1 M?
Source Accuracy ±4%
Settling Time 64 mSec
Analog Current Input
Current Range 0 to 20mA
Resolution 0.020345mA
Typical Accuracy ±0.29% full scale
Loop Supply >+20Vdc, ±0.6Vdc
Settling Time 200mSec
Digital Input 1 (Pulse Counter/Contact Closure/Timer)
Zero Input Voltage 0 to 0.5Vdc (or Shorted Input)
High Input Voltage 2.4 to 10Vdc (or Open Circuit)
Count Range 216
Maximum Frequency >2500Hz counting; 40Hz Interval
Minimum Pulse Width 25mSec
Timer Range 24 Hrs
Timer Resolution 1mSec
Digital Input 2 (Pulse Counter/Contact Closure)
Zero Input Voltage 0 to 0.5Vdc (or Shorted Input)
High Input Voltage 2.4 to 10Vdc (or Open Circuit)
Count Range 232
Maximum Frequency 2500Hz
Minimum Pulse Width 200µSec

General Specifications

Physical Size
Dimensions 3.5 in x 3.25 in x 2in. (89mm x 83mm x 51mm)
Weight 8 oz. (227g)
General
Sampling Rate User Settable 30sec – 24hrs
Emergency Data Storage 250 Samples per Sensor
Power Options
Option #1 100-240Vac 50-60Hz
Option #2 DC Input 4-7Vdc
Option #3 3 x AA Batteries (6 month life at 5 minute sampling intervals)
Wireless
Range 250ft Outdoors, 90ft Indoors
Topology Mesh
Standard IEEE 802.15.4
Frequency 2.4GHz DSS
Power Output -0.79dBm
Operating Environment
Operation temperature when using Lithium batteries -40°C to 70°C, 5-95%rh
Operation temperature when using Alkaline batteries -20°C to 50°C, 5-95%rh

Application Notes

Below features our collection of application notes and case studies involving this product.

Differential Pressure and Temperature Monitoring in a Hospital Cleanroom

Remote Monitoring of Medical Incubators for Temperature and CO2 Level

Request Pricing & Information

If you need information right away or prefer to speak with a person, call us and one of our Experienced Applications Engineers will be happy to talk with you. You can reach us at 1-800-956-4437 during our normal business hours Monday - Friday from 8am to 6pm (EDT).

After filling out the form below, an applications engineer will contact you within at least one business day.

Indicates a required field.

Fields that are not required are recommended to be filled out so that we can better assist you.

Request Form

Name Address 1
Email Address 2
Phone # City
Company State
Job Title Zip
Fax # Country
Product(s)

of Interest
Application
Additional

Information
Human Verification What is the next number after 5?  
Newsletter Sign Up - Here at CAS Data Loggers we are constantly publishing new articles, and now you can receive monthly emails to see what's new. By signing up for our monthly newsletter, you will also receive the newest application notes where our products are being used and many other resources such as white papers, videos, technical articles and new product information.

Home | About CAS | Policies | Distributor Login | Systems Integrators

©2011 Computer Aided Solutions, LLC.