ADwin-Gold Real-Time Data Acquisition and Control System

16 Channel Real-Time Data Acquisition

Product Overview
  • 2 x 8 Analog Inputs (multiplexed) with 14-bit or 16-bit resolution
  • 2 x 16-Bit ADC (5 μs) and 2 X 14-Bit ADC (0.5 μs)
  • 2 Analog Outputs, 16-Bit (option to add up to 8 outputs)
  • 32 Digital I/O's, TTL/CMOS Compatible, in blocks of 8 (selectable as input or output)
  • 1 Trigger Input - TTL/CMOS Compatible
  • 16 MB of external DRAM for data storage
  • Integrated Ethernet or USB interface for PC Communication
  • Software Calibration of Analog I/O
  • ADSP21062 DSP CPU (32-Bit, 40 MHz, 256 kB CPU RAM)
  • Robust and Compact Metal Enclosure
Useful Links
ADwin-Gold Real-Time Data Acquisition System


Manufacturer - ADwin

Model Number - ADWIN-GOLD

Product Spec Sheet

Real-time DAQ


Click to enlarge

The ADwin-Gold is a powerful Real-Time system in a very compact and robust design. It includes many functions in a small package at a reasonable price. The ADwin-Gold is housed in a rugged, metal enclosure that includes: a fast, local Real-Time CPU and memory, analog and digital inputs and outputs; as well as a USB or Ethernet interface for the communication with a PC. The local CPU enables input and output response times of 1 μs or less.

Analog Inputs

The analog inputs are connected via two 8-channel MUX and two PGA to 2×16-bit and 2×14-bit ADCs. Signal acquisition is controlled by the ADwin’s CPU, and possible to acquire two channels simultaneously without any phase-shift, critical for correlated signals. The ADwin-Gold has 2- or 8-analog outputs with an output range is ±10V.

Digital Inputs

The ADwin-Gold provides 32 programmable digital input and output channels at 5V-TTL/CMOS level, plus an Event input. The channels can be software selected in blocks of 8 as inputs or outputs. Optional configurations allow additional features such as counters, quadrature encoder interfaces, RS-232/485, automotive CANbus and SSI interfaces.

ADwin operation with the PC

Multiple PCs can communicate with one ADwin system concurrently. This may be useful during the program implementation and comissioning. On the other hand, one PC can also access multiple ADwin systems e.g. in a network for a centralized monitoring of various applications.

While working with ADwin, the first step is always to download the real-time operating system to the ADwin system via the Ethernet or USB interface. Then, the ADbasic real-time processes can be loaded and started or stopped as required. Single values or whole data sets (arrays), e.g. measured or set-point values can be exchanged bi-directionally. The deterministic (exact and predictable in time) execution of the real-time processes is not affected by the communcation between ADwin and the PC.

Real-time development with ADbasic and ADtools

With ADbasic, you define the processing sequences that are executed on the ADwin hardware. ADbasic optimizes and compiles the program code on a mouse-click. After being loaded on the ADwin system by ADbasic or a graphical PC user interface, the real-time processes execute independently. ADbasic contains the functions to access all inputs and outputs as well as functions for floating-point operations, process control and communication with the PC. A library is provided which contains standard functions e.g. for filtering, various examples for counter use, closed-loop controllers, function generators etc. which leads to a faster program implementation.

By means of the easily configurable ADtools you are able to display your real-time data graphically or numerically, to visualize process sequencings or to set input values via potentiometers, sliders or push buttons. Additionally, ADtools always provide you with the current status of your ADwin system resources.

Click here for more information on ADwin software

ADwin-Gold Systems
ADwin-Gold System features
1 processor ADSP, 32-bit, 40MHz, 256KB int./16MB RAM, 1x event input
2x 8 analog inputs ±10V multiplexed to 2x 16-bit ADC (5µs)
2 analog outputs ±10V 16-bit DAC (3µs)
2x 14-bit ADC(0.5µs)
16 digital inputs, 16 digital outputs,
comptact metal enclosure, supply voltage range 10-35V
ADwin-Gold-ENET ADwin-Gold with Ethernet interface (10/100 MBit/s)
BNC sockets for analog signals
ADwin-Gold-D-ENET ADwin-Gold with Ethernet interface (10/100 MBit/s)
D-SUB sockets for analog signals
ADwin-Gold-USB ADwin-Gold with USB interface
BNC sockets for analog signals
ADwin-Gold-D-USB ADwin-Gold with USB interface
D-SUB sockets for analog signals
ADwin-Gold Options (Options for the standard system, later upgrading is not possible)
Gold-CO1 4x 32-bit up/down counter (TTL), 4-edge evaluation
clock/direct, period width measurement
Gold-CAN Option for ADwin-Gold-D: 2x CAN-Bus, 2x RS232/485
4x SSI decoder
Gold-CAN-LS Option for ADwin-Gold-D: 2x CAN-Bus Low Speed, 2x RS232/485
4x SSI decoder
Gold-DA Option: 6 addtional analog outputs, 16-bit DAC (3µs)
Gold-Boot Bootloader option, for Ethernet only, for stand-alone operation without PC,
10 MB non-volatile data memory, fetch / write support for S7 SPS
Gold-MEM64 Memory expansion from 16MB ext. memory to 64MB and
memory expansion from 256KB int. memory to 512KB
ADwin-Gold Accessories
Gold-Pow External power supply 12V DC for ADwin-Gold
Gold-Mount DIN-rail installation kit for the ADwin-Gold-EXT system
Gold-Pow-Mount Extneral power supply for mounting on DIN-rail, 12V DC for ADwin-Gold
HSM-24V 32 digital I/Os, 24V level, configurable in groups of 8
DIN-rail module for LS-Bus interface, screw-type connector
ADbasic Fast real-time development tool for ADwin systems, version 5

Application Notes

Below features our collection of application notes and case studies involving this product.

Material Testing: Monitoring Metal Fatigue Crack Growth

Request Pricing & Information

If you need information right away or prefer to speak with a person, call us and one of our Experienced Applications Engineers will be happy to talk with you. You can reach us at 1-800-956-4437 during our normal business hours Monday - Friday from 8am to 6pm (EDT).

After filling out the form below, an applications engineer will contact you within at least one business day.

Indicates a required field.

Fields that are not required are recommended to be filled out so that we can better assist you.

Request Form

Name Address 1
Email Address 2
Phone # City
Company State
Job Title Zip
Fax # Country
Product(s)

of Interest
Application
Additional

Information
Human Verification What is the next number after 1?  
Newsletter Sign Up - Here at CAS Data Loggers we are constantly publishing new articles, and now you can receive monthly emails to see what's new. By signing up for our monthly newsletter, you will also receive the newest application notes where our products are being used and many other resources such as white papers, videos, technical articles and new product information.

Home | About CAS | Policies | Distributor Login | Systems Integrators

©2011 Computer Aided Solutions, LLC.