The ADwin-Pro is a modular data acquisition system housed in a bench top or rack mountable enclosure. Different I/O boards and expansion modules allow the ADwin-Pro to be configured for specific uses. Communication with the host PC can be done through either a USB, Ethernet. Plug-in boards support Analog and Digital I/O, Counter/Timers, PWM signal I/O, thermocouples and RTD’s, 5B or MB input modules, Serial, CAN, and Fieldbus communication.
On-board Processor
The on-board processor with its own local memory handles system management, data acquisition, on-line processing and control of outputs. Processing of each measurement can occur immediately after acquisition.The ADbasic control language allows users to program mathematical operations and functions which are executed immediately after each sampling step even at sampling rates as high as 1.25 MHz. More than one processor can be used in the system for applications that demand the highest possible throughput.
Software
The ADwin software environment can be used under Windows (2000/XP/Vista/Win7) and Linux, or as a stand-alone data acquisition system. Also, ADwin has drivers for many of the popular programming environments including Visual Basic, Visual C/C++, LabVIEW/LabWindows, TestPoint and others.
ADwin operation with the PC
Multiple PCs can communicate with one ADwin system concurrently. This may be useful during the program implementation and comissioning. On the other hand, one PC can also access multiple ADwin systems e.g. in a network for a centralized monitoring of various applications.
While working with ADwin, the first step is always to download the real-time operating system to the ADwin system via the Ethernet or USB interface. Then, the ADbasic real-time processes can be loaded and started or stopped as required. Single values or whole data sets (arrays), e.g. measured or set-point values can be exchanged bi-directionally. The deterministic (exact and predictable in time) execution of the real-time processes is not affected by the communcation between ADwin and the PC.
Real-time development with ADbasic and ADtools
With ADbasic, you define the processing sequences that are executed on the ADwin hardware. ADbasic optimizes and compiles the program code on a mouse-click. After being loaded on the ADwin system by ADbasic or a graphical PC user interface, the real-time processes execute independently. ADbasic contains the functions to access all inputs and outputs as well as functions for floating-point operations, process control and communication with the PC. A library is provided which contains standard functions e.g. for filtering, various examples for counter use, closed-loop controllers, function generators etc. which leads to a faster program implementation.
By means of the easily configurable ADtools you are able to display your real-time data graphically or numerically, to visualize process sequencings or to set input values via potentiometers, sliders or push buttons. Additionally, ADtools always provide you with the current status of your ADwin system resources.
The following modules are available:
- Processor Modules
- Analog Input / Output Modules
- Digital input / output modules
- Counter modules
- Interface modules for various buses
- Temperature measurement , active or passive
- Special modules
Processor Modules
The heart of ADwin Pro
The processor module is the center of each ADwin-Pro system. It leads into the ADbasic of programmed commands and accesses the inputs and outputs, and interfaces of the other modules.
The following processor modules are available:
- Per-CPU-T10
- ADSP21162 (80 MHz)
- 128 MB DRAM, 512 MB RAM CPU
- Trigger Input
- Ethernet interface (10/100 Mbps, TCP / IP) for PC communication
- Boot Loader option for stand-alone operation
- Per-CPU-T9
- ADSP21062 (40 MHz)
- 16 MB DRAM, 256 MB RAM, CPU, optional 64 MB RAM and 512 MB RAM CPU
- Trigger Input
- Ethernet (10/100 Mbps, TCP / IP) or USB interface for PC communication
- Boot Loader option for stand-alone operation
Back to Top
Analog Input / Output Modules
Interfaces for analog signals
The analog input and output modules provide the interface to your measurement devices, analog transmitters, amplifiers or actuators. The ADwin Pro -input modules are available either with a multiplexed converters for all channels or with one converter per channel.
Analog input and output modules:
- Multiplexed inputs
- 8, 16 or 32 channels
- 12, 14 or 16 bit resolution
- Parallel analog inputs
- one ADC per channel for synchronous acquisition of all channels
- 4 - or 8 - channel
- 14 or 16 bit resolution
- Analog Outputs
- 4 - or 8 - channel
- 16 bit resolution
- PT100 Amplifier Modules
- Modules for thermocouples type J or K
- Carrier module for 5B modules
- Modules with filters, sample and hold stage and analog isolation amplifiers
- Custom input / output modules, for example, with comparator
Back to Top
Digital input / output modules
ADwin-Pro and digital signals
Digital input and output modules are the interfaces to your digital gauges and transmitters. Select the digital modules to suit your type of signal.
Digital output modules
- Comparator input card, 16 channels, Resolution 1024 steps, at threshold -2 ... 8V (customized customizable)
- TTL inputs / outputs
- Optocoupler inputs 5 V, 12 V, 24 V
- Transistor switching outputs 5 ... 30 V
- Relay outputs to 30 V
- Custom input / output modules
Back to Top
Counter modules
Counter modules for high speed digital signals
The ADwin Pro -counter modules can be, for example, for connection of incremental encoders, the event count or pulse width modulation.
- Universal counter module, individually configurable 32-bit counter for the modes
- Pulse counter
- PWM analysis, period measurement
- Incremental input clock / direction or A / B with 4-edge evaluation
- 2 SSI inputs, 5 V differential (RS-422)
- Counter module, pulse counter
- PWM outputs
- Various inputs
- TTL
- 5 V differential (RS-422)
- optically isolated 5 V / 12 V / 24 V
Back to Top
Bus Modules
Communication on all sides
ADwin Pro modules work with a variety of bus and serial interfaces. A ADwin Pro -system can simultaneously send messages and data via RS232 control via CAN-Bus devices and control a test.
The following interfaces are available:
- Pro-RS232 x 2 or 4 RS-232
- Pro-422-x: 2 or 4 RS-422
- Pro-485-x: 2 or 4 RS-485
- Pro-CAN-x: 1 or 2 CAN bus, Low-Speed ??or High-Speed
- Pro LS-2: 2 interfaces into a bidirectional serial bus with 5 MHz clock rate. The coach works with the module HSM-24V processed, the 24V signals.
- Pro-Pro-SL DP: Profibus slave interface
- Inter-Pro-GM: Interbus slave interface
- Other fieldbus interfaces on request
Back to Top
Temperature measurement , active or passive
Flexible temperature sensing with ADwin Pro
The modules are temperature-it is in passive or active version. The active modules have the analog-digital conversion (ADC) on the module and allow the query either the temperature or the applied voltage. The passive modules convert the thermocouple signals and output the voltage to an analog input module further.
Select the appropriate module:
- PT100 Amplifier Modules
- Passive modules for thermocouples type J or K
- Active module for thermocouple types B, E, J, K, N, R, S, T
Back to Top
Special modules
Pro-STORAGE
Carrier module for PC-free storage of large amounts of data in the FAT 16/32 file system
Used as storage media Type II PC Card (PCMCIA) are:
- Solid state flash memory (such as CF, SD, SM)
- Hard drives (such as Type II PC Card HDD, Microdrive ™)
- Filter and analog isolation amplifiers
- Filter and analog isolation amplifiers are available as standard modules for Aufsteckvarianten.
Custom Modules
If you have special requirements that meet our standard modules or not your job requires special functions, we program that best serves you.
Back to Top
| ADwin-Pro Standard Enclosures | |
|---|---|
| ADwin-Pro |
19" enclosure (84 HP, 3U) AC power supply 115/230V 16 slots desktop unit all modules mounted from the frontside |
| ADwin-Pro-BM |
19" enclosure (84 HP, 3U) AC power supply 115/230V 15 slots desktop unit all modules mounted from the backside |
| ADwin-Pro-DC |
19" enclosure (84 HP, 3U) AC power supply 10-35V 16 slots desktop unit all modules mounted from the frontside |
| ADwin-Pro-light |
½ 19" enclosure (42HP, 3U) AC power supply 115/230V 7 slots desktop unit all modules mounted from the frontside |
| ADwin-Pro-mini-2 |
Enclosure (25HP, 3U) DC-DC converter 10-18V 5 slots desktop unit all modules mounted from the frontside |
| ADwin-Pro-mini-3 |
Enclosure (25HP, 3U) DC-DC converter 20-36V 5 slots desktop unit all modules mounted from the frontside |
Application Notes
Below features our collection of application notes and case studies involving this product.
Cold Atom Quantum Physics Experiment
Request Pricing & Information
If you need information right away or prefer to speak with a person, call us and one of our Experienced Applications Engineers will be happy to talk with you. You can reach us at 1-800-956-4437 during our normal business hours Monday - Friday from 8am to 6pm (EDT).
After filling out the form below, an applications engineer will contact you within at least one business day.
* Indicates a required field.
Fields that are not required are recommended to be filled out so that we can better assist you.