ADwin-Pro Modular Real Time Data Acquisition and Control System

Modular Real-Time DAQ

Product Overview
  • Analog In (Multiplex and Parallel A/D), Analog Out, Digital I/O, Counters, CAN, Serial Cards
  • Full, Half and Quarter Rack Mainframes, AC or DC Power Versions
  • High Performance DSP Processor
  • Up to 480 Analog Inputs, Digital I/O or a Combination of These
Useful Links
ADwin-Pro Real-Time Data Acquisition System


Manufacturer - ADwin

Model Number - ADWIN-PRO

Product Spec Sheet

Modular DAQ

The ADwin-Pro is a modular data acquisition system housed in a bench top or rack mountable enclosure. Different I/O boards and expansion modules allow the ADwin-Pro to be configured for specific uses. Communication with the host PC can be done through either a USB, Ethernet. Plug-in boards support Analog and Digital I/O, Counter/Timers, PWM signal I/O, thermocouples and RTD’s, 5B or MB input modules, Serial, CAN, and Fieldbus communication.

On-board Processor

The on-board processor with its own local memory handles system management, data acquisition, on-line processing and control of outputs. Processing of each measurement can occur immediately after acquisition.The ADbasic control language allows users to program mathematical operations and functions which are executed immediately after each sampling step even at sampling rates as high as 1.25 MHz. More than one processor can be used in the system for applications that demand the highest possible throughput.

Software

The ADwin software environment can be used under Windows (2000/XP/Vista/Win7) and Linux, or as a stand-alone data acquisition system. Also, ADwin has drivers for many of the popular programming environments including Visual Basic, Visual C/C++, LabVIEW/LabWindows, TestPoint and others.

ADwin operation with the PC

Multiple PCs can communicate with one ADwin system concurrently. This may be useful during the program implementation and comissioning. On the other hand, one PC can also access multiple ADwin systems e.g. in a network for a centralized monitoring of various applications.

While working with ADwin, the first step is always to download the real-time operating system to the ADwin system via the Ethernet or USB interface. Then, the ADbasic real-time processes can be loaded and started or stopped as required. Single values or whole data sets (arrays), e.g. measured or set-point values can be exchanged bi-directionally. The deterministic (exact and predictable in time) execution of the real-time processes is not affected by the communcation between ADwin and the PC.

Real-time development with ADbasic and ADtools

With ADbasic, you define the processing sequences that are executed on the ADwin hardware. ADbasic optimizes and compiles the program code on a mouse-click. After being loaded on the ADwin system by ADbasic or a graphical PC user interface, the real-time processes execute independently. ADbasic contains the functions to access all inputs and outputs as well as functions for floating-point operations, process control and communication with the PC. A library is provided which contains standard functions e.g. for filtering, various examples for counter use, closed-loop controllers, function generators etc. which leads to a faster program implementation.

By means of the easily configurable ADtools you are able to display your real-time data graphically or numerically, to visualize process sequencings or to set input values via potentiometers, sliders or push buttons. Additionally, ADtools always provide you with the current status of your ADwin system resources.

Click here for more information on ADwin software

The following modules are available:

Processor Modules


The heart of ADwin Pro

The processor module is the center of each ADwin-Pro system. It leads into the ADbasic of programmed commands and accesses the inputs and outputs, and interfaces of the other modules.

The following processor modules are available:

  • Per-CPU-T10
    • ADSP21162 (80 MHz)
    • 128 MB DRAM, 512 MB RAM CPU
    • Trigger Input
    • Ethernet interface (10/100 Mbps, TCP / IP) for PC communication
    • Boot Loader option for stand-alone operation
  • Per-CPU-T9
    • ADSP21062 (40 MHz)
    • 16 MB DRAM, 256 MB RAM, CPU, optional 64 MB RAM and 512 MB RAM CPU
    • Trigger Input
    • Ethernet (10/100 Mbps, TCP / IP) or USB interface for PC communication
    • Boot Loader option for stand-alone operation

Back to Top

Analog Input / Output Modules


Interfaces for analog signals

The analog input and output modules provide the interface to your measurement devices, analog transmitters, amplifiers or actuators. The ADwin Pro -input modules are available either with a multiplexed converters for all channels or with one converter per channel.

Analog input and output modules:

  • Multiplexed inputs
    • 8, 16 or 32 channels
    • 12, 14 or 16 bit resolution
  • Parallel analog inputs
    • one ADC per channel for synchronous acquisition of all channels
    • 4 - or 8 - channel
    • 14 or 16 bit resolution
  • Analog Outputs
    • 4 - or 8 - channel
    • 16 bit resolution
  • PT100 Amplifier Modules
  • Modules for thermocouples type J or K
  • Carrier module for 5B modules
  • Modules with filters, sample and hold stage and analog isolation amplifiers
  • Custom input / output modules, for example, with comparator

Back to Top

Digital input / output modules


ADwin-Pro and digital signals

Digital input and output modules are the interfaces to your digital gauges and transmitters. Select the digital modules to suit your type of signal.

Digital output modules

  • Comparator input card, 16 channels, Resolution 1024 steps, at threshold -2 ... 8V (customized customizable)
  • TTL inputs / outputs
  • Optocoupler inputs 5 V, 12 V, 24 V
  • Transistor switching outputs 5 ... 30 V
  • Relay outputs to 30 V
  • Custom input / output modules

Back to Top

Counter modules


Counter modules for high speed digital signals

The ADwin Pro -counter modules can be, for example, for connection of incremental encoders, the event count or pulse width modulation.

  • Universal counter module, individually configurable 32-bit counter for the modes
    • Pulse counter
    • PWM analysis, period measurement
    • Incremental input clock / direction or A / B with 4-edge evaluation
    • 2 SSI inputs, 5 V differential (RS-422)
  • Counter module, pulse counter
  • PWM outputs
  • Various inputs
    • TTL
    • 5 V differential (RS-422)
    • optically isolated 5 V / 12 V / 24 V

Back to Top

Bus Modules


Communication on all sides

ADwin Pro modules work with a variety of bus and serial interfaces. A ADwin Pro -system can simultaneously send messages and data via RS232 control via CAN-Bus devices and control a test.

The following interfaces are available:

  • Pro-RS232 x 2 or 4 RS-232
  • Pro-422-x: 2 or 4 RS-422
  • Pro-485-x: 2 or 4 RS-485
  • Pro-CAN-x: 1 or 2 CAN bus, Low-Speed ??or High-Speed
  • Pro LS-2: 2 interfaces into a bidirectional serial bus with 5 MHz clock rate. The coach works with the module HSM-24V processed, the 24V signals.
  • Pro-Pro-SL DP: Profibus slave interface
  • Inter-Pro-GM: Interbus slave interface
  • Other fieldbus interfaces on request

Back to Top

Temperature measurement , active or passive


Flexible temperature sensing with ADwin Pro

The modules are temperature-it is in passive or active version. The active modules have the analog-digital conversion (ADC) on the module and allow the query either the temperature or the applied voltage. The passive modules convert the thermocouple signals and output the voltage to an analog input module further.

Select the appropriate module:

  • PT100 Amplifier Modules
  • Passive modules for thermocouples type J or K
  • Active module for thermocouple types B, E, J, K, N, R, S, T

Back to Top

Special modules


Pro-STORAGE

Carrier module for PC-free storage of large amounts of data in the FAT 16/32 file system

Used as storage media Type II PC Card (PCMCIA) are:

  • Solid state flash memory (such as CF, SD, SM)
  • Hard drives (such as Type II PC Card HDD, Microdrive ™)
  • Filter and analog isolation amplifiers
  • Filter and analog isolation amplifiers are available as standard modules for Aufsteckvarianten.

Custom Modules

If you have special requirements that meet our standard modules or not your job requires special functions, we program that best serves you.


Back to Top

ADwin-Pro Standard Enclosures
ADwin-Pro 19" enclosure (84 HP, 3U)
AC power supply 115/230V
16 slots
desktop unit
all modules mounted from the frontside
ADwin-Pro-BM 19" enclosure (84 HP, 3U)
AC power supply 115/230V
15 slots
desktop unit
all modules mounted from the backside
ADwin-Pro-DC 19" enclosure (84 HP, 3U)
AC power supply 10-35V
16 slots
desktop unit
all modules mounted from the frontside
ADwin-Pro-light ½ 19" enclosure (42HP, 3U)
AC power supply 115/230V
7 slots
desktop unit
all modules mounted from the frontside
ADwin-Pro-mini-2 Enclosure (25HP, 3U)
DC-DC converter 10-18V
5 slots
desktop unit
all modules mounted from the frontside
ADwin-Pro-mini-3 Enclosure (25HP, 3U)
DC-DC converter 20-36V
5 slots
desktop unit
all modules mounted from the frontside

Application Notes

Below features our collection of application notes and case studies involving this product.

Cold Atom Quantum Physics Experiment

Request Pricing & Information

If you need information right away or prefer to speak with a person, call us and one of our Experienced Applications Engineers will be happy to talk with you. You can reach us at 1-800-956-4437 during our normal business hours Monday - Friday from 8am to 6pm (EDT).

After filling out the form below, an applications engineer will contact you within at least one business day.

Indicates a required field.

Fields that are not required are recommended to be filled out so that we can better assist you.

Request Form

Name Address 1
Email Address 2
Phone # City
Company State
Job Title Zip
Fax # Country
Product(s)

of Interest
Application
Additional

Information
Human Verification What is the next number after 8?  
Newsletter Sign Up - Here at CAS Data Loggers we are constantly publishing new articles, and now you can receive monthly emails to see what's new. By signing up for our monthly newsletter, you will also receive the newest application notes where our products are being used and many other resources such as white papers, videos, technical articles and new product information.

Home | About CAS | Policies | Distributor Login | Systems Integrators

©2011 Computer Aided Solutions, LLC.