L481 DC High Voltage Data Logger
AEMC L481 Data Logger
|
Product Overview
Applications
|
The Simple Logger® II model L481 DC Voltage Data Logger provides an extended voltage measurement range of ±850 VDC with a resolution of 0.1V making is suitable for applications such as monitoring rail voltages, machines, windmills, power supplies and battery packs and for finding intermittent voltage problems.
The L481 can be programmed to sample from 8 times per second to once a day. It can store up to 240,000 measurements in internal non-volatile memory and offers 3 recording modes including Extended Recording Mode (XRM®) for long term data collection. The L481 is battery powered and can operate up to 45 days on 2x AA cells. A simple LED display on the front of the logger provides an immediate indication of logging status and memory usage. Voltage inputs are via standard recessed banana jacks and a set of 5 foot cables with alligator clips are included with the logger.
For set-up and download of data, the L481 logger has a USB 2.0 interface for connection to a standard Windows PC. The free DataView® software included with the unit provides a very simple way to configure the logger, view real-time data, download and plot stored data and generate standard or custom reports. It also allows the measured data to be scaled to custom engineering units and can synchronize multiple loggers to record at the same time.
| Electrical | |
|---|---|
| Channels | One |
| Input Connection | Two recessed 4mm saftey banana jacks |
| Measurement Range | ±850V DC |
| Resolution | 0.1V |
| Accuracy(50/60Hz) |
0 to 5V: unspecified 5 to 50V: ±(0.5% of Reading + 1V) 50 to 850V: ±(0.5% of Reading + 0.5V) |
| Sample Rate | 8 samples/storage internval |
| Storage Rate | Programmable from 125mS to 1 day |
| Storage Modes |
Start/Stop Mode First In First Out Mode (FIFO) Extended Time Recording Mode (XRM) |
| Recording Length | 15 minutes to 8 weeks, programmable using DataView |
| Memory | 240,000 measurements (512KB) The recorded data is stored in non-volatile memory & retained even if the battery is low or removed. |
| Communication | USB 2.0 optically isolated |
| Power Source | 2 x 1.5V AA-cell Alkaline batteries |
| Battery Life | 100 hours to >45 days (dependent on storage rate/recording length) |
| Mechanical | |
| Dimensions | 4.94 x 2.75 x 1.28" (125 x 70 x 32mm) |
| Weight (with battery) | 6.4 oz (181 grams) |
| Case | UL94-V0 |
| Vibration | IEC 68-2-6 (1.5mm, 10 to 55Hz) |
| Shock | IEC 68-2-27 (30G) |
| Drop | IEC 68-2-32 (1m) |
Start/Stop Mode
In this mode the operator selects a storage rate from predefined values from 8 per second to 1 every day, then selects a start and stop time. Data is recorded at this rate until the memory is filled or the end recording time and date is reached. The logger then stops recording and goes into standby mode retaining the recorded date.
First In First Out Mode (FIFO)
The operator makes the data storage and recording length selections as described above. If the memory fills before the end date and time occurs, the logger will discard the oldest stored data point and add a new one. This process will continue until the end recording date and time is reached.
Extended Time Recording Mode (XRM)
This unique recording mechanism provides for continuous recording over a longer period of time without the need for the operator's selection or adjustments. The operator selects a starting storage range from predefined values from 8 per second to 1 every day and a recording length. The logger will store data at the rate selected until the memory is filled. The logger will then discard every other stored sample beyond the first one, freeing up half the memory for continuous recording. New samples will be stored at half the previous storage rate, matching the interval with the remaining stored data. This process will repeat each time the memory fills until the operator stops the recording manually, the end recording date and time is reached or the battery runs down.
Request Pricing & Information
If you need information right away or prefer to speak with a person, call us and one of our Experienced Applications Engineers will be happy to talk with you. You can reach us at 1-800-956-4437 during our normal business hours Monday - Friday from 8am to 6pm (EDT).
After filling out the form below, an applications engineer will contact you within at least one business day.
* Indicates a required field.
Fields that are not required are recommended to be filled out so that we can better assist you.