Data Loggers For All Applications
Data Loggers for All Applications
1 - 800 - 956 - 4437
Monday - Friday
8am - 6pm (EDT)
Find a data logger by selecting an application from the list below.
Request Pricing & Information
Home -> AEMC -> L481 DC High Voltage Data Logger

L481 DC High Voltage Data Logger

AEMC L481 Data Logger

Product Overview
  • Measures up to ±850 VDC
  • Storage rate of 8x per second to once/day
  • Store up to 240,000 measurements
  • USB 2.0 communication interface
  • Simple LED status display
  • Battery powered
Applications
  • Rail voltage monitoring
  • Battery testing
  • Power supply monitoring
  • Windmill monitoring
  • Intermittent voltage fault detection
L481 DC High Voltage Data Logger


Manufacturer - AEMC

Model Number - L481

Product Spec Sheet

The Simple Logger® II model L481 DC Voltage Data Logger provides an extended voltage measurement range of ±850 VDC with a resolution of 0.1V making is suitable for applications such as monitoring rail voltages, machines, windmills, power supplies and battery packs and for finding intermittent voltage problems.

The L481 can be programmed to sample from 8 times per second to once a day. It can store up to 240,000 measurements in internal non-volatile memory and offers 3 recording modes including Extended Recording Mode (XRM®) for long term data collection. The L481 is battery powered and can operate up to 45 days on 2x AA cells. A simple LED display on the front of the logger provides an immediate indication of logging status and memory usage. Voltage inputs are via standard recessed banana jacks and a set of 5 foot cables with alligator clips are included with the logger.

For set-up and download of data, the L481 logger has a USB 2.0 interface for connection to a standard Windows PC. The free DataView® software included with the unit provides a very simple way to configure the logger, view real-time data, download and plot stored data and generate standard or custom reports. It also allows the measured data to be scaled to custom engineering units and can synchronize multiple loggers to record at the same time.


Click image to enlarge

Data Analysis and Reporting Software for Data Loggers

Configure all data logger functions

  • Display and analyze real-time data on your PC
  • Configure all data logger functions and parameters from your PC including sample rate, recording length, channel configuration and more
  • Create and store a complete library of configurations that can be uploaded to the logger as needed
  • Zoom in and out and pan through sections of the graph to analyze the data
  • Download, display and analyze recorded data
  • Display waveforms, trend graphs, harmonics (AC models) and text summaries
  • Create custom views and reports
  • Print reports using standard or custom templates you design




Click image to enlarge
Tabbed configuration dialog boxes allow for easy setup of all recording functions.




Click image to enlarge
Recorded data dialog box allows clear and easy access to all stored data sessions in the Sentinel® data logger. You can choose an individual session or all sessions to download.




Click image to enlarge
Harmonic content information can be displayed in a text format for all harmonics out to the 30th.




Click image to enlarge
Clear and easy-to-read status update is displayed when DataView® and Sentinel® Loggers connect. From this menu you can view real-time data, download recorded data and configure the Sentinel® Logger.




Click image to enlarge
Typical real-time waveform display of data being monitored or recorded.




Click image to enlarge
Harmonic content displayed in bargraph form in real time using DataView® for any or all inputs.
Electrical
Channels One
Input Connection Two recessed 4mm saftey banana jacks
Measurement Range ±850V DC
Resolution 0.1V
Accuracy(50/60Hz) 0 to 5V: unspecified
5 to 50V: ±(0.5% of Reading + 1V)
50 to 850V: ±(0.5% of Reading + 0.5V)
Sample Rate 8 samples/storage internval
Storage Rate Programmable from 125mS to 1 day
Storage Modes Start/Stop Mode
First In First Out Mode (FIFO)
Extended Time Recording Mode (XRM)
Recording Length 15 minutes to 8 weeks, programmable using DataView
Memory 240,000 measurements (512KB) The recorded data is stored in non-volatile memory & retained even if the battery is low or removed.
Communication USB 2.0 optically isolated
Power Source 2 x 1.5V AA-cell Alkaline batteries
Battery Life 100 hours to >45 days (dependent on storage rate/recording length)
Mechanical
Dimensions 4.94 x 2.75 x 1.28" (125 x 70 x 32mm)
Weight (with battery) 6.4 oz (181 grams)
Case UL94-V0
Vibration IEC 68-2-6 (1.5mm, 10 to 55Hz)
Shock IEC 68-2-27 (30G)
Drop IEC 68-2-32 (1m)

Start/Stop Mode

In this mode the operator selects a storage rate from predefined values from 8 per second to 1 every day, then selects a start and stop time. Data is recorded at this rate until the memory is filled or the end recording time and date is reached. The logger then stops recording and goes into standby mode retaining the recorded date.

First In First Out Mode (FIFO)

The operator makes the data storage and recording length selections as described above. If the memory fills before the end date and time occurs, the logger will discard the oldest stored data point and add a new one. This process will continue until the end recording date and time is reached.

Extended Time Recording Mode (XRM)

This unique recording mechanism provides for continuous recording over a longer period of time without the need for the operator's selection or adjustments. The operator selects a starting storage range from predefined values from 8 per second to 1 every day and a recording length. The logger will store data at the rate selected until the memory is filled. The logger will then discard every other stored sample beyond the first one, freeing up half the memory for continuous recording. New samples will be stored at half the previous storage rate, matching the interval with the remaining stored data. This process will repeat each time the memory fills until the operator stops the recording manually, the end recording date and time is reached or the battery runs down.

Request Pricing & Information

If you need information right away or prefer to speak with a person, call us and one of our Experienced Applications Engineers will be happy to talk with you. You can reach us at 1-800-956-4437 during our normal business hours Monday - Friday from 8am to 6pm (EDT).

After filling out the form below, an applications engineer will contact you within at least one business day.

Indicates a required field.

Fields that are not required are recommended to be filled out so that we can better assist you.

Request Form

Name Address 1
Email Address 2
Phone # City
Company State
Job Title Zip
Fax # Country
Product(s)

of Interest
Application
Additional

Information
Human Verification What is the next number after 8?  
Newsletter Sign Up - Here at CAS Data Loggers we are constantly publishing new articles, and now you can receive monthly emails to see what's new. By signing up for our monthly newsletter, you will also receive the newest application notes where our products are being used and many other resources such as white papers, videos, technical articles and new product information.

Home | About CAS | Policies | Distributor Login | Systems Integrators

©2011 Computer Aided Solutions, LLC.