DT80G Intelligent Vibrating Wire Data Logger
Datataker DT80G Geotechnical Data Logger
|
Product Overview
Useful Links
|
The Geo-technical Logger
Supporting vibrating wire sensors the new dataTaker DT80G GeoLogger is ideal for all geotechnical data logging applications. The dataTaker GeoLoggers have built-in vibrating wire support providing ideal data acquisition and monitoring solution for the engineer working in the geotechnical environment.
The dataTaker GeoLoggers can monitor a wide variety of geotechnical datalogging applications including slope stability, subsidence, dam wall monitoring, tunnel and mining excavation, ground water, tunnel wall monitoring and site assessment.
The advanced new dataTaker DT80G range Geologgers are compatible with all major brands of geotechnical instrumentation including Slope Indicator, RST Instruments, Geokon, Soil Instruments, Roctest, AGI - Applied Geomechanics Inc.
Communication Features
The low cost, low power dataTaker DT80G is extremely versatile and easy to configure for communications, data capture and data analysis. View the data in real time or store up to 5 million data points. Data storage and retrieval can be achieved via USB memory stick, FTP, cell phone, Modbus for SCADA, Ethernet or Web.
Universal & Configurable
The dataTaker DT80G has 5 analog channels capable of measuring up to 5 vibrating wire strain gauges with thermistors or 15 vibrating wire strain gauges without thermistors. If additional channels are required the dataTaker DT85G has 16/48 vibrating wire channels. The DT80G and DT85G can be expanded simply by connecting dataTaker Channel Expansion Modules (CEM20) to provide 100 to 300 vibrating wire channels with thermistors.
dEX Software
dEX is an intuitive graphical interface that allows you to configure your data logger, view real-time data in mimics, trend charts or tables and retrieve your historical data for analysis.
dEX runs directly from your web browser and can be accessed either locally or remotely, anywhere that a TCP/IP connection is available including worldwide over the Internet. You can use any of the logger’s built-in communications ports to view dEX including Ethernet, USB and RS-232.
- Built-in software - no application to install
- Runs directly from your web browser
- Accessible by Ethernet or USB connection
- Intuitive graphical interface
- Easy-to-use configuration editor
- Access live and historical data
- View data charts, mimics and tables
Real Time Trending
Real-time trending for sensors, calculations or other data. Supports up-to 5 traces per chart and up-to 2 Y-axes. Backfills with historical data stored in logger.
Real Time Displays
dEX displays real-time sensor measurements, calculations and diagnostic information, including mimics, tables and trend charts
Configuration Made Easy
The configuration editor allows you to view, edit and save logger configurations in an easy-to-use Windows Explorer style user interface. Tree view of configuration allows definition of measurement schedules and measurements.
Wiring diagrams show possible wiring configuration for selected sensor type. Configuration can be stored and retrieved on either the logger or a local computer

|
|
20 Channel Expansion Module CEM20A dataTaker CEM20 connects to one analogue channel of the dataTaker data logger. Each CEM20 connects 20 universal data logging channels.
|
|
|
CANgate CANbus to Serial ConverterThe dataTaker CANgate CAN to ASCII gateway filters and converts CAN (Controller Area Network) and GPS (Global Positioning System) data to serial ASCII data.
|
|
|
Portable Enclosure
|
|
|
Industrial Enclosure
|
| Analog Channels | |
|---|---|
| Analog Channels |
2 Wire w/ Com. Ref. Terminal: 15 Channels (expandable to 300*) 2 Wire Isolated: 10 Channels (expandable to 200*) 3 or 4 Wire Isolated: 5 Channels (expandable to 100*) * Expansion requires optional CEM20 |
| Analog Inputs |
Inter-Channel Isolation: 100 Volts (Relay Switching) Analog Section Isolation: 100 Volts (Opto-Isolated) Input Impedance: 100 K Ohm, >100M Ohm Common Mode Range: ±3.5V or ±35V on 30 Volts Range |
| Analog Measurement Ranges |
Voltage: ±30 mVdc; ±300 mVdc; ±3 Vdc; ±30 Vdc Current: ±0.3 mA; ±3 mA; ±30 mA Resistance: 100 Ohm; 1,000 Ohm; 10,000 Ohm Frequency: 100Hz; 10 kHz |
| Analog Measurement Resolution |
Voltage: 0.25µV; 2.5µV; 0.25µV; 250µV Current: 2.5nA; 25 nA ; 250 nA Resistance: 1.5 m Ohm; 15 m Ohm; 150 m Ohm Frequency: 0.0002%; 0.0002% |
| Accuracy |
DC Voltage: 0.1% (5°C to 40°C); 0.35% (-45°C to 70°C) DC Current: 0.15% (5°C to 40°C); 0.45% (-45°C to 70°C) DC Resistance: 0.1% (5°C to 40°C); 0.35% (-45°C to 70°C) Frequency: 0.1% (5°C to 40°C); 0.25% (-45°C to 70°C) |
| Sampling |
Integrates over 50/60 Hz Line Period for Accuracy and Noise Rejection Maximum Sample Speed: 25 Hz Effective Resolution: 18 Bits Linearity: 0.01% Common Mode Rejection: >90dB Line Series Mode Rejection: > 35dB |
| Sensor Excitation (Supply) |
Analog Channles: Selectable 250µA or 2.5mA Precision Current Source, 4.5V Voltage Source, or Switched External Supply General Purpose: Switchable 12V Regulated Supply for Powering Sensors & Accessories (Max. 150mA) |
| Analog Sensors | |
|---|---|
| Vibrating Wire |
Frequency range: 500 to 5kHz Coil resistance: 50 to 200 Ohm Stimulation method: single pulse pluck |
| Carlson Sensors | Built-in functions for strain and temperature. |
| Thermocouples |
Type: B, C, D, E, G, J, K, N, R S, T Calibration Standard: ITS-90 |
| RTDs |
Materials Supported: Pt, Ni, Cu Resistance Range: 10O to 10K Ohm |
| Thermistors |
Type: YSI 400xx Series, other Types* Resistance Range: <10kO** * Other Thermistor Types are Supported by Thermistor Scaling and Calculated Channels ** Resistance Range Can Be Increased with the Use of a Parallel Resistor. |
| Monolithic Temperature Sensors | Type: LM34 - 60, AD590, AD592, TMPxx, LM135, LM235, LM335 |
| Strain Gauge and Bridge Sensors |
Configurations: 1/4, 1/2 & Full Bridge Excitation: Voltage or Current |
| 4-20mA Current Loop | Internal 100R Shunt or External Shunt Resistor |
| Digital Channels | |
|---|---|
| Digital Input/Outputs |
8 Bi-Directional Channels Digital Input Type: 8 Logic Level (Max. 20/30 Volts) Digital Output Type: 4 With Open Drain FET (Max. 30V, 100mA), 4 with Logic Output |
| Relay Output | 1 Latching Relay, contacts (Max: 30Vdc, 1A) |
| Counter Channels | |
|---|---|
| Low Speed Counters |
-- 8 Counters Shared with Digital Inputs -- 32 Bit Size -- 10 Hz Max Count Rate -- Low Speed Counters do not Function in Sleep Mode |
| Dedicated Counter Channels |
-- 4 High Speed Inputs or 2 phase encoder (quadrature inputs) -- 32 Bit Size -- 100kHz Max Count Rate -- 2 Logic Level Inputs (Max ±30V) -- 2 Sensitive Inputs (10mV) for Magnetic Pick Ups (Max. ±10V) |
| Serial Channels | |
|---|---|
| SDI-12 |
-- 4 SDI-12 Inputs, Shared with Digital Channels -- Each input can support multiple SDI-12 Sensors |
| Generic Serial Sensor |
Flexible Option for Logging From Wide Range of Smart Sensors and Data Streams Available ports: Serial Sensor Port (RS232, RS422, RS485) or Host RS232 Port* Baud Rate: 300 to 115,200 * If used as a Serial Sensor channel then the Host Port is Not Available for Other Communications |
| Calculated Channels | |
|---|---|
| General | Combine values from analog, digital and serial sensors using expressions involving variables and functions. |
| Functions | Arithmetic, Trigonometric, Relational, Logical and Statistical |
| Alarms | |
|---|---|
| Condition | High, Low or Within Range and Outside Range |
| Delay | Optional Time Period for Alarm Response |
| Actions | Set Digital Outputs, Transmit Message, Execute any DataTaker Command |
| Scheduling of Data Acquisition | |
|---|---|
| Condition | High, Low or Within Range and Outside Range |
| Number of schedules | 11 |
| Schedule rates | 10ms to days |
| Internal Data Storage | Capacity: 128mb = approx 10,000,000 data points |
| Removable USB storage device |
Type:compatible with USb 1.1 or USB 2.0 drivers, e.g. Flash drive Capacity: approx 90,000 data points per megabyte |
| Communication Interfaces | |
|---|---|
| Ethernet Port |
Interface: 10BasteT (10Mbps) Protocol: TCP/IP |
| USB Port |
Interface: USB 1.1 (virtual COM port) Protocol: ASCII command |
| Host RS232 Port |
Speed: 300 to 115,200 Baud (57,600 Default) Flow Control: Hardware (RTS/CTS), Software (XON/XOFF), None Handshake Lines: DCD, DSR, DTR, RTS, CTS Modem Support: Auto-Answer and Dial Out Protocols: ASCII Command, TCP/IP (PPP), Serial Sensor, Modbus |
| Serial Sensor Port |
Interface: RS232, RS422m, RS485 Speed: 300 to 57,600 baud Flow Control: Hardware (RTS/CTS) Software: (XON/XOFF), None Protocols: Modbus (master & slave), Serial Sensor |
| Network TCP/IP Services | |
|---|---|
| Network | Ethernet and/or Host RS232 (PPP) Communication Ports |
| Command Interface | Access the ASCII command interface via TCP/IP |
| Web Server |
-- Access Current Data and Status from any Web Browser -- Download Data in CSV Format -- Command Interface Window -- Define Mimic Displays |
| Modbus Server(slave) | Access current data and status from any Modbus client |
| FTP Server | Access logged data from any FTP client or web browser |
| FTP Client | Automatically upload logged data direct to an FTP server. |
| System | |
|---|---|
| Display and Keypad |
Type: LCD, 2 Line by 16 Characters, Backlight Functions: Channel Data, Alarms, System Status Keypad: 6 Keys for Scrolling and Function Execution Status LEDs: 4 (Sample, Disk, Attention, Power) |
| Firmware Upgrade | Via: RS232, Ethernet, USB disk. |
| Real Time Clock |
Normal resolution: 200µs Accuracy: ±1 min/year (0°C to 40°C), ±4 min/year (-40°C to 70°C) |
| Power Supply |
External Voltage Range: 10 to 30 Volts DC Internal battery: Not available Peak Power: 12 W (12VDC 1A) |
| Average power Consumption |
Using 12Vdc external power source 1 Sec Sampling: 1350 mW 5 Sec Sampling: 500 mW 30 Sec Sampling: 135 mW 5 Min Sampling: 70 mW 1 Hr Sampling: 60 mW |
| Typical Operating Time |
from internal 6Vdc, 1.2Ahr battery
1 Sec Sampling: 6.5 hours 5 Sec Sampling: 1 day 1 Min Sampling: 10 days 1 Hr Sampling: 3.5 months |
| Physical Environment | |
|---|---|
| Construction | Powder Coated Steel & Anodized Aluminum |
| Dimensions | 180 x 137 x 65mm |
| Weight | 1.5kg (4kg shipping) |
| Operating Range |
Temperature: -45°C to 70°C (Reduced LCD Operation Outside Range: -15°C to 50°C) Humidity: 85% RH, Non-condensing |
Request Pricing & Information
If you need information right away or prefer to speak with a person, call us and one of our Experienced Applications Engineers will be happy to talk with you. You can reach us at 1-800-956-4437 during our normal business hours Monday - Friday from 8am to 6pm (EDT).
After filling out the form below, an applications engineer will contact you within at least one business day.
* Indicates a required field.
Fields that are not required are recommended to be filled out so that we can better assist you.