Datataker DT80G Geotechnical Data Logger

Product Overview
  • 5 to 15 Universal Analog Sensor Channels
  • Vibrating Wire Strain Gauge Support
  • ±30 V Input Measurement Range
  • 12 Digital Channels
  • Serial Sensor Channel
  • Built-in Display
  • USB Memory Slot for Easy Data Transfer
  • Ethernet, USB, or RS-232 Communication with PC
  • SDI-12 and Modbus Sensor Support
  • Modem Support
  • Easy-to-use, Configurable, Windows-based Software
  • Stand-alone and Real-time Data Acquisition
  • Remote Monitoring and Control
  • Removable Screw Terminals
Useful Links
datataker DT80G geotechnical data logger


Manufacturer - dataTaker

Model Number - DT80G

Product Spec Sheet

The Geo-technical Logger

Supporting vibrating wire sensors the new dataTaker DT80G GeoLogger is ideal for all geotechnical data logging applications. The dataTaker GeoLoggers have built-in vibrating wire support providing ideal data acquisition and monitoring solution for the engineer working in the geotechnical environment.

The dataTaker GeoLoggers can monitor a wide variety of geotechnical datalogging applications including slope stability, subsidence, dam wall monitoring, tunnel and mining excavation, ground water, tunnel wall monitoring and site assessment.

The advanced new dataTaker DT80G range Geologgers are compatible with all major brands of geotechnical instrumentation including Slope Indicator, RST Instruments, Geokon, Soil Instruments, Roctest, AGI - Applied Geomechanics Inc.

Communication Features

The low cost, low power dataTaker DT80G is extremely versatile and easy to configure for communications, data capture and data analysis. View the data in real time or store up to 5 million data points. Data storage and retrieval can be achieved via USB memory stick, FTP, cell phone, Modbus for SCADA, Ethernet or Web.

Universal & Configurable

The dataTaker DT80G has 5 analog channels capable of measuring up to 5 vibrating wire strain gauges with thermistors or 15 vibrating wire strain gauges without thermistors. If additional channels are required the dataTaker DT85G has 16/48 vibrating wire channels. The DT80G and DT85G can be expanded simply by connecting dataTaker Channel Expansion Modules (CEM20) to provide 100 to 300 vibrating wire channels with thermistors.

dEX Software

dEX is an intuitive graphical interface that allows you to configure your data logger, view real-time data in mimics, trend charts or tables and retrieve your historical data for analysis.

dEX runs directly from your web browser and can be accessed either locally or remotely, anywhere that a TCP/IP connection is available including worldwide over the Internet. You can use any of the logger’s built-in communications ports to view dEX including Ethernet, USB and RS-232.

  • Built-in software - no application to install
  • Runs directly from your web browser
  • Accessible by Ethernet or USB connection
  • Intuitive graphical interface
  • Easy-to-use configuration editor
  • Access live and historical data
  • View data charts, mimics and tables

Real Time Trending

Real-time trending for sensors, calculations or other data. Supports up-to 5 traces per chart and up-to 2 Y-axes. Backfills with historical data stored in logger.



Real Time Displays

dEX displays real-time sensor measurements, calculations and diagnostic information, including mimics, tables and trend charts



Configuration Made Easy

The configuration editor allows you to view, edit and save logger configurations in an easy-to-use Windows Explorer style user interface. Tree view of configuration allows definition of measurement schedules and measurements.

Wiring diagrams show possible wiring configuration for selected sensor type. Configuration can be stored and retrieved on either the logger or a local computer

20 Channel Expansion Module CEM20

A dataTaker CEM20 connects to one analogue channel of the dataTaker data logger. Each CEM20 connects 20 universal data logging channels.

  • Up to 60 analog inputs per CEM20
  • Compact size with low power consumption
  • Up to 5 units for DT80 = 100 channels/300 inputs
  • Up to 16 units for DT85 = 320 channels/960 inputs

CANgate CANbus to Serial Converter

The dataTaker CANgate CAN to ASCII gateway filters and converts CAN (Controller Area Network) and GPS (Global Positioning System) data to serial ASCII data.

  • Designed for real-time data capture
  • 2 CANbus interface ports, 10 to 1000 Kbits/second
  • 1 RS-232 GPS port
  • 1 RS-232 Host port

Portable Enclosure

  • Black ABS plastic with neoprene seal and stainless steel hinge(can be submersed for short periods, withstands 800kg stacking loads)
  • Use with lid open, or install glands for cable entry (lid can be padlocked)
  • Houses one dataTaker and battery in the steel Lugg-a-Logger cradle (removable), with additional space for a Channel Expansion Module, cables, etc.

Industrial Enclosure

  • Powder-coated sheet steel with polyurethane door seal: rated to IP66/NEMA4
  • 400 x 200 x 120, 4.5kg (holds 1 dataTaker / Channel Expansion Module, plus battery)
  • Door has 110(R) hinges for easy access, with a cam lock. (key lock optional)
  • Panel-Mount Display can be installed into door
  • Internal equipment mounting kits included.
Analog Channels
Analog Channels 2 Wire w/ Com. Ref. Terminal: 15 Channels (expandable to 300*)
2 Wire Isolated: 10 Channels (expandable to 200*)
3 or 4 Wire Isolated: 5 Channels (expandable to 100*)
* Expansion requires optional CEM20
Analog Inputs Inter-Channel Isolation: 100 Volts (Relay Switching)
Analog Section Isolation: 100 Volts (Opto-Isolated)
Input Impedance: 100 K Ohm, >100M Ohm
Common Mode Range: ±3.5V or ±35V on 30 Volts Range
Analog Measurement Ranges Voltage: ±30 mVdc; ±300 mVdc; ±3 Vdc; ±30 Vdc
Current: ±0.3 mA; ±3 mA; ±30 mA
Resistance: 100 Ohm; 1,000 Ohm; 10,000 Ohm
Frequency: 100Hz; 10 kHz
Analog Measurement Resolution Voltage: 0.25µV; 2.5µV; 0.25µV; 250µV
Current: 2.5nA; 25 nA ; 250 nA
Resistance: 1.5 m Ohm; 15 m Ohm; 150 m Ohm
Frequency: 0.0002%; 0.0002%
Accuracy DC Voltage: 0.1% (5°C to 40°C); 0.35% (-45°C to 70°C)
DC Current: 0.15% (5°C to 40°C); 0.45% (-45°C to 70°C)
DC Resistance: 0.1% (5°C to 40°C); 0.35% (-45°C to 70°C)
Frequency: 0.1% (5°C to 40°C); 0.25% (-45°C to 70°C)
Sampling Integrates over 50/60 Hz Line Period for Accuracy and Noise Rejection
Maximum Sample Speed: 25 Hz
Effective Resolution: 18 Bits
Linearity: 0.01%
Common Mode Rejection: >90dB
Line Series Mode Rejection: > 35dB
Sensor Excitation (Supply) Analog Channles: Selectable 250µA or 2.5mA Precision Current Source, 4.5V Voltage Source, or Switched External Supply
General Purpose: Switchable 12V Regulated Supply for Powering Sensors & Accessories (Max. 150mA)
Analog Sensors
Vibrating Wire Frequency range: 500 to 5kHz
Coil resistance: 50 to 200 Ohm
Stimulation method: single pulse pluck
Carlson Sensors Built-in functions for strain and temperature.
Thermocouples Type: B, C, D, E, G, J, K, N, R S, T
Calibration Standard: ITS-90
RTDs Materials Supported: Pt, Ni, Cu
Resistance Range: 10O to 10K Ohm
Thermistors Type: YSI 400xx Series, other Types*
Resistance Range: <10kO**
* Other Thermistor Types are Supported by Thermistor Scaling and Calculated Channels
** Resistance Range Can Be Increased with the Use of a Parallel Resistor.
Monolithic Temperature Sensors Type: LM34 - 60, AD590, AD592, TMPxx, LM135, LM235, LM335
Strain Gauge and Bridge Sensors Configurations: 1/4, 1/2 & Full Bridge
Excitation: Voltage or Current
4-20mA Current Loop Internal 100R Shunt or External Shunt Resistor
Digital Channels
Digital Input/Outputs 8 Bi-Directional Channels
Digital Input Type: 8 Logic Level (Max. 20/30 Volts)
Digital Output Type: 4 With Open Drain FET (Max. 30V, 100mA), 4 with Logic Output
Relay Output 1 Latching Relay, contacts (Max: 30Vdc, 1A)
Counter Channels
Low Speed Counters -- 8 Counters Shared with Digital Inputs
-- 32 Bit Size
-- 10 Hz Max Count Rate
-- Low Speed Counters do not Function in Sleep Mode
Dedicated Counter Channels -- 4 High Speed Inputs or 2 phase encoder (quadrature inputs)
-- 32 Bit Size
-- 100kHz Max Count Rate
-- 2 Logic Level Inputs (Max ±30V)
-- 2 Sensitive Inputs (10mV) for Magnetic Pick Ups (Max. ±10V)
Serial Channels
SDI-12 -- 4 SDI-12 Inputs, Shared with Digital Channels
-- Each input can support multiple SDI-12 Sensors
Generic Serial Sensor Flexible Option for Logging From Wide Range of Smart Sensors and Data Streams
Available ports: Serial Sensor Port (RS232, RS422, RS485) or Host RS232 Port*
Baud Rate: 300 to 115,200
* If used as a Serial Sensor channel then the Host Port is Not Available for Other Communications
Calculated Channels
General Combine values from analog, digital and serial sensors using expressions involving variables and functions.
Functions Arithmetic, Trigonometric, Relational, Logical and Statistical
Alarms
Condition High, Low or Within Range and Outside Range
Delay Optional Time Period for Alarm Response
Actions Set Digital Outputs, Transmit Message, Execute any DataTaker Command
Scheduling of Data Acquisition
Condition High, Low or Within Range and Outside Range
Number of schedules 11
Schedule rates 10ms to days
Internal Data Storage Capacity: 128mb = approx 10,000,000 data points
Removable USB storage device Type:compatible with USb 1.1 or USB 2.0 drivers, e.g. Flash drive
Capacity: approx 90,000 data points per megabyte
Communication Interfaces
Ethernet Port Interface: 10BasteT (10Mbps)
Protocol: TCP/IP
USB Port Interface: USB 1.1 (virtual COM port)
Protocol: ASCII command
Host RS232 Port Speed: 300 to 115,200 Baud (57,600 Default)
Flow Control: Hardware (RTS/CTS), Software (XON/XOFF), None
Handshake Lines: DCD, DSR, DTR, RTS, CTS
Modem Support: Auto-Answer and Dial Out
Protocols: ASCII Command, TCP/IP (PPP), Serial Sensor, Modbus
Serial Sensor Port Interface: RS232, RS422m, RS485
Speed: 300 to 57,600 baud
Flow Control: Hardware (RTS/CTS)
Software: (XON/XOFF), None
Protocols: Modbus (master & slave), Serial Sensor
Network TCP/IP Services
Network Ethernet and/or Host RS232 (PPP) Communication Ports
Command Interface Access the ASCII command interface via TCP/IP
Web Server -- Access Current Data and Status from any Web Browser
-- Download Data in CSV Format
-- Command Interface Window
-- Define Mimic Displays
Modbus Server(slave) Access current data and status from any Modbus client
FTP Server Access logged data from any FTP client or web browser
FTP Client Automatically upload logged data direct to an FTP server.
System
Display and Keypad Type: LCD, 2 Line by 16 Characters, Backlight
Functions: Channel Data, Alarms, System Status
Keypad: 6 Keys for Scrolling and Function Execution
Status LEDs: 4 (Sample, Disk, Attention, Power)
Firmware Upgrade Via: RS232, Ethernet, USB disk.
Real Time Clock Normal resolution: 200µs
Accuracy: ±1 min/year (0°C to 40°C), ±4 min/year (-40°C to 70°C)
Power Supply External Voltage Range: 10 to 30 Volts DC
Internal battery: Not available
Peak Power: 12 W (12VDC 1A)
Average power Consumption Using 12Vdc external power source
1 Sec Sampling: 1350 mW
5 Sec Sampling: 500 mW
30 Sec Sampling: 135 mW
5 Min Sampling: 70 mW
1 Hr Sampling: 60 mW
Typical Operating Time from internal 6Vdc, 1.2Ahr battery 1 Sec Sampling: 6.5 hours
5 Sec Sampling: 1 day
1 Min Sampling: 10 days
1 Hr Sampling: 3.5 months
Physical Environment
Construction Powder Coated Steel & Anodized Aluminum
Dimensions 180 x 137 x 65mm
Weight 1.5kg (4kg shipping)
Operating Range Temperature: -45°C to 70°C (Reduced LCD Operation Outside Range: -15°C to 50°C)
Humidity: 85% RH, Non-condensing

Request Pricing & Information

If you need information right away or prefer to speak with a person, call us and one of our Experienced Applications Engineers will be happy to talk with you. You can reach us at 1-800-956-4437 during our normal business hours Monday - Friday from 8am to 6pm (EDT).

After filling out the form below, an applications engineer will contact you within at least one business day.

Indicates a required field.

Fields that are not required are recommended to be filled out so that we can better assist you.

Request Form

Name Address 1
Email Address 2
Phone # City
Company State
Job Title Zip
Fax # Country
Product(s)

of Interest
Application
Additional

Information
Human Verification What is the next number after 4?  
Newsletter Sign Up - Here at CAS Data Loggers we are constantly publishing new articles, and now you can receive monthly emails to see what's new. By signing up for our monthly newsletter, you will also receive the newest application notes where our products are being used and many other resources such as white papers, videos, technical articles and new product information.

Home | About CAS | Policies | Distributor Login | Systems Integrators

©2011 Computer Aided Solutions, LLC.