DT82EM Intelligent Environmental Data Logger with Modem
Same Functionality as DT82E with built in cellular modem
|
Product Overview
Useful Links
|
Internal GSM Modem
The dataTaker DT82EM is an intelligent data logger that incorporates a built-in GSM modem with email and SMS support for automated data and alarm transfer from remote sites. The DT82EM features USB memory stick support, 18 bit resolution, extensive communications capabilities and built-in display. The dataTaker DT82EM’s Dual Channel Isolation allows 4, 2 wire differential or 6 common referenced analog inputs to be used in many combinations.
Remote Monitoring
Based on the very successful DT8x platform, the DT82EM is designed specifically for remote data logging applications where conventional access to the logger is difficult and for mobile applications in vehicles.The software provides FTP and email data transfer along with SMS and email alarm notifications. The dEX web based software allows configuration of the data logger, real-time monitoring and data download using a standard web browser – no special software is required.
Versatile Channels
Analog and digital channels, along with high-speed counter inputs, allow the DT82EM data logger to easily connect to most sensors and data measurement sources. Temperature, voltage, current, 4-20mA loops, resistance, bridges, strain gauges, frequency, digital, serial and calculated measurements can all be scaled, logged and returned in engineering units or within statistical reporting. Group sampling, logging, alarm and control tasks within schedules to suit your requirements.
Large Storage
Store up to 10 million data points in user defined memory, log a much or as little as you need with independent control of schedule size and mode. Overwrite or stop logging once allocated memory is full. Archive data on alarm event, copy to USB memory or transfer via FTP, the choice is yours.
Versatile Communications
Communications features include HTTP, FTP,email and SMS using the internal GSM modem, Ethernet and USB memory stick ports. Connect to the DT82EM locally, remotely or over the Internet. The web interface allows users to configure the DT82EM, access logged data and see current measurements as mimics or in a list using a web browser. FTP provides data to your office over the internet or mobile phone network, without the need for polling or specific host software.
dEX Software
dEX is an intuitive graphical interface that allows you to configure your data logger, view real-time data in mimics, trend charts or tables and retrieve your historical data for analysis.
dEX runs directly from your web browser and can be accessed either locally or remotely, anywhere that a TCP/IP connection is available including worldwide over the Internet. You can use any of the logger’s built-in communications ports to view dEX including Ethernet, USB and RS-232.
- Built-in software - no application to install
- Runs directly from your web browser
- Accessible by Ethernet or USB connection
- Intuitive graphical interface
- Easy-to-use configuration editor
- Access live and historical data
- View data charts, mimics and tables
Real Time Trending
Real-time trending for sensors, calculations or other data. Supports up-to 5 traces per chart and up-to 2 Y-axes. Backfills with historical data stored in logger.
Real Time Displays
dEX displays real-time sensor measurements, calculations and diagnostic information, including mimics, tables and trend charts
Configuration Made Easy
The configuration editor allows you to view, edit and save logger configurations in an easy-to-use Windows Explorer style user interface. Tree view of configuration allows definition of measurement schedules and measurements.
Wiring diagrams show possible wiring configuration for selected sensor type. Configuration can be stored and retrieved on either the logger or a local computer

|
|
20 Channel Expansion Module CEM20A dataTaker CEM20 connects to one analogue channel of the dataTaker data logger. Each CEM20 connects 20 universal data logging channels.
|
|
|
CANgate CANbus to Serial ConverterThe dataTaker CANgate CAN to ASCII gateway filters and converts CAN (Controller Area Network) and GPS (Global Positioning System) data to serial ASCII data.
|
|
|
Portable Enclosure
|
|
|
Industrial Enclosure
|
| Inbuilt Modem | |
|---|---|
| Features |
Alarms: Send email or SMS messages Data: Send data to an email address or FTP server Remote access: Connect to dEX or Command interface SIM interface: SIM Socket (1.8V/3V) |
| Networks Interfaces |
USA Only: EDGE, GPRS, GSM, CSD All Other places: EDGE, GPRS, GSM, WCDMA, HSUPA, HSDPA |
| Frequencies |
EDGE/GPRS/GSM: 850/900/1800/1900 MHz WCDMA/HSUPA/HSDPA: 850/1900/2100 MHz |
| Analog Channels | |
|---|---|
| Data Channels |
Up to 6 Analog Channels Up to 4 Flexible Digital Channels |
| Analog Channels |
2 Wire w/ Com. Ref. Terminal: 6 Channels 2 Wire Isolated: 4 Channels 3 or 4 Wire Isolated: 2 Channels |
| Analog Inputs |
Inter-Channel Isolation: 100 Volts (Relay Switching) Analog Section Isolation: 100 Volts (Opto-Isolated) Input Impedance: 100 KO, >100MO Common Mode Range: ±3.5V or ±35V on 30 Volts Range |
| Analog Measurement Ranges |
Voltage: ±30 mVdc; ±300 mVdc; ±3 Vdc; ±30 Vdc Current: ±0.3 mA; ±3 mA; ±30 mA Resistance: 100O; 1,000O; 10,000O Frequency: 100Hz; 10 kHz |
| Analog Measurement Resolution |
Voltage: 0.25µV; 2.5µV; 0.25µV; 250µV Current: 2.5nA; 25 nA ; 250 nA Resistance: 1.5 mO; 15 mO; 150 mO Frequency: 0.0002%; 0.0002% |
| Accuracy |
DC Voltage: 0.1% (5°C to 40°C); 0.35% (-45°C to 70°C) DC Current: 0.15% (5°C to 40°C); 0.45% (-45°C to 70°C) DC Resistance: 0.1% (5°C to 40°C); 0.35% (-45°C to 70°C) Frequency: 0.1% (5°C to 40°C); 0.25% (-45°C to 70°C) |
| Sampling |
Integrates over 50/60 Hz Line Period for Accuracy and Noise Rejection Maximum Sample Speed: 25 Hz Effective Resolution: 18 Bits Linearity: 0.01% Common Mode Rejection: >90dB Line Series Mode Rejection: > 35dB |
| Sensor Excitation (Supply) |
Analog Channles: Selectable 250µA or 2.5mA Precision Current Source, 4.5V Voltage Source, or Switched External Supply General Purpose: Switchable 12V Regulated Supply for Powering Sensors & Accessories (Max. 150mA). Switchable 5V regulated supply for powering analog sensors (max25mA). |
| Analog Sensors | |
|---|---|
| Thermocouples |
Type: B, C, D, E, G, J, K, N, R S, T Calibration Standard: ITS-90 |
| RTDs |
Materials Supported: Pt, Ni, Cu Resistance Range: 10O to 10KO |
| Thermistors |
Type: YSI 400xx Series, other Types* Resistance Range: <10kO** * Other Thermistor Types are Supported by Thermistor Scaling and Calculated Channels ** Resistance Range Can Be Increased with the Use of a Parallel Resistor. |
| Monolithic Temperature Sensors | Type: LM34 - 60, AD590, AD592, TMPxx, LM135, LM235, LM335 |
| Strain Gauge and Bridge Sensors |
Configurations: 1/4, 1/2 & Full Bridge Excitation: Voltage or Current |
| 4-20mA Current Loop | Internal 100R Shunt or External Shunt Resistor |
| Digital Channels | |
|---|---|
| Digital Input/Outputs |
4 Bi-Directional Channels Digital Input Type: 4 Logic Level (Max. 20/30 Volts) Digital Output Type: 3 With Open Drain FET (Max. 30V, 100mA), 1 with Logic Output |
| Relay Output | 1 Latching Relay, contacts (Max: 30Vdc, 1A) |
| Counter Channels | |
|---|---|
| Low Speed Counters |
-- 4 Counters Shared with Digital Inputs -- 32 Bit Size -- 10 Hz Max Count Rate -- Low Speed Counters do not Function in Sleep Mode |
| Dedicated Counter Channels |
-- 4 High Speed Inputs -- 32 Bit Size -- 10kHz Max Count Rate -- 2 Logic Level Inputs (Max ±30V) -- 2 Sensitive Inputs (10mV) for Magnetic Pick Ups (Max. ±10V) |
| Serial Channels | |
|---|---|
| SDI-12 |
-- 1 SDI-12 Inputs, Shared with Digital Channels -- Each input can support up to 10 SDI-12 Sensors |
| Calculated Channels | |
|---|---|
| General | Combine values from analog, digital and serial sensors using expressions involving variables and functions. |
| Functions | Arithmetic, Trigonometric, Relational, Logical and Statistical |
| Alarms | |
|---|---|
| Condition | High, Low or Within Range and Outside Range |
| Delay | Optional Time Period for Alarm Response |
| Actions | Set Digital Outputs, Transmit Message, Execute any DataTaker Command |
| Scheduling of Data Acquisition | |
|---|---|
| Condition | High, Low or Within Range and Outside Range |
| Number of schedules | 11 |
| Schedule rates | 10ms to days |
| Internal Data Storage | Capacity: 128mb = approx 10,000,000 data points |
| Removable USB storage device |
Type:compatible with USb 1.1 or USB 2.0 drivers, e.g. Flash drive Capacity: approx 90,000 data points per megabyte |
| Communication Interfaces | |
|---|---|
| Ethernet Port |
Interface: 10BasteT (10Mbps) Protocol: TCP/IP |
| Network TCP/IP Services | |
|---|---|
| Network | Ethernet and/or Host RS232 (PPP) Communication Ports |
| Command Interface | Access the ASCII command interface via TCP/IP |
| Web Server |
-- Access Current Data and Status from any Web Browser -- Download Data in CSV Format -- Command Interface Window -- Define Mimic Displays |
| Email Client | Email data or alarms directly from the logger |
| DDNS Client | Brwose to the logger over the Internet using Dynamic DNS |
| FTP Server | Access logged data from any FTP client or web browser. |
| FTP Client | Automatically upload logged data direct to an FTP server. |
| System | |
|---|---|
| Display and Keypad |
Type: LCD, 2 Line by 16 Characters, Backlight Functions: Channel Data, Alarms, System Status Keypad: 6 Keys for Scrolling and Function Execution Status LEDs: 4 (Sample, Disk, Attention, Power) |
| Firmware Upgrade | Via: Ethernet, USB disk. |
| Real Time Clock |
Normal resolution: 200µs Accuracy: ±1 min/year (0°C to 40°C), ±4 min/year (-40°C to 70°C) |
| Power Supply |
External Voltage Range: 10 to 30 Volts DC Peak Power: 12W |
| Average power Consumption (typtical) |
1 Sec Sampling: 560 mW (1 Sample); 926 mW (6 Samples) 5 Sec Sampling: 250 mW (1 Sample); 337 mW (6 Samples) 30 Sec Sampling: 50 mW (1 Sample); 65 mW (6 Samples) 1 Min Sampling: 30 mW (1 Sample); 38 mW (6 Samples) 5 Min Sampling: 14 mW (1 Sample); 16 mW (6 Samples) 30 Min Sampling: 11 mW (1 Sample); 11 mW (6 Samples) 1 Hr Sampling: 11 mW (1 Sample); 11 mW (6 Samples) |
| Physical Environment | |
|---|---|
| Construction | Powder Coated Steel & Anodized Aluminum |
| Dimensions | 18.0 cm x 13.7 cm x 6.5 cm (180mm x 137mm x 65mm) |
| Weight | 900 grams |
| Operating Range |
Temperature: -45°C to 70°C (Reduced LCD Operation Outside Range: -15°C to 50°C) Humidity: 85% RH, Non-condensing |
Request Pricing & Information
If you need information right away or prefer to speak with a person, call us and one of our Experienced Applications Engineers will be happy to talk with you. You can reach us at 1-800-956-4437 during our normal business hours Monday - Friday from 8am to 6pm (EDT).
After filling out the form below, an applications engineer will contact you within at least one business day.
* Indicates a required field.
Fields that are not required are recommended to be filled out so that we can better assist you.
©2011 Computer Aided Solutions, LLC.