Data Loggers For All Applications
Data Loggers for All Applications
1 - 800 - 956 - 4437
M-Th 8A-5:30P(EDT)
Fri     8A-4:30P(EDT)
Find a data logger by selecting an application from the list below.
Request Pricing & Information
Home -> Novus -> DigiRail

DigiRail

Signal conditioning and digital transmitter

Product Overview
  • Power: 10-35 Vdc
  • Consumption: 50 mA
  • RS485 (2-wire) Modbus RTU communication
  • Windows software configurator
  • Dimensions: 71 x 77 x 19 mm
  • Sensor break detection for t/c and RTD
  • Analog input resolution: 17 bits
  • User defined linearization option for the analog inputs
  • Accuracy (@ 25 °C): ±0.25% FS ±1°C for thermocouples, ±0.15% FS for Pt100, mV, V and mA
  • Isolation: 1000 Vac/1 min from digital or analog input to power or communications port
Useful Links


Manufacturer - Novus

Model Number - DigiRail

Product Spec Sheet

The DigiRail line of smart transmitters with Modbus RTU communication interface provide a simple way for integrating analog or digital signal to supervisory systems. Featuring up to two universal input analog signal channels they are the most econmical way to deliver analog input to PLC's and SCADA systems.

The input signal are isolated from power thus protecting the electrical instruments by eliminating ground loop effects. This reduces substantially the undesirable interferences and instabilities in sensor measurements

DigiRail can be easily configured and calibrated via the digital interface by using the Windows based DigiConfig software.

Models


The DigiRail line of transmitters includes 3 models, based on their input or output types:

  • DigiRail-1A and DigiRail-2A, with 1 or 2 universal analog inputs respectively
  • DigiRail-4C, with 4 digital counters
  • DigiRail-2R, with 2 timer relay outputs


Configuration


DigiRail Configuration is done via the RS485 interface by using Modbus RTU commands.

The DigiConfig software allows for configuration of all DigiRail features as well as complete calibration and diagnosis. It automatically detects active devices in the Modbus network and permits configuration of all parameters.



Specifications


  • Analog inputs: programmable for thermocouples (J, K, T, E, N, R, S, B), Pt100, mV, V, mA. Refer to table 1.
  • Cold junction compensation for thermocouples and compensation for Pt100 3-wire cables.
  • Open loop detection for thermocouples, Pt100 and mV.
  • Sampling rate for 1 analog input: 10Hz for mV, V and mA. 5Hz for T thermocouples and Pt100.
  • Analog input resolution: 17 bits.
  • Digital inputs: in voltage, 4 to 35V to activate internally limited current in 5 mA
  • Digital outputs: 8A / 250 Vac SPDT relay, resistive load.
  • Power: 10 to 35 Vdc, 50mA maximum current.
  • 2-wire RS485 communication with Modbus RTU protocol. Configurable address and baud rate (1,200 to 115,200bps).
  • LED indicators for communication and status. Key for resetting communication parameters to original factory default.
  • Accuracy (at 25°C): Pt100, mV, V and mA: ±0.15% of full scale. Thermocouples: ±0.25% of full scale.
  • Temperature effect: 0.003% of full scale/°
  • Cold junction compensation for thermocouples: ±1°C at 25°C. ±0.05 °C/°C
  • Isolation: 1000 Vac from inputs (analog or digital) and power or communication. Communication and power are not isolated from one another nor are the analog inputs from each other. Every two digital inputs are isolated from other pairs of same inputs.
  • Windows.based configurator software.
  • Dimensions: 72 x 78 x 19mm.
  • Mounting: 35mm DIN rail. Refer to drawing.
  • Working temperature: 0 to 70°C


Electrical Connections




Block Diagrams




Input Types and Maximum Ranges




Dimensions


Request Pricing & Information

If you need information right away or prefer to speak with a person, call us and one of our Experienced Applications Engineers will be happy to talk with you. You can reach us at 1-800-956-4437 during our normal business hours Monday - Friday from 8am to 6pm (EDT).

After filling out the form below, an applications engineer will contact you within at least one business day.

Indicates a required field.

Fields that are not required are recommended to be filled out so that we can better assist you.

Request Form

Name Address 1
Email Address 2
Phone # City
Company State
Job Title Zip
Fax # Country
Product(s)

of Interest
Application
Additional

Information
Human Verification What is the next number after 5?  
Newsletter Sign Up - Here at CAS Data Loggers we are constantly publishing new articles, and now you can receive monthly emails to see what's new. By signing up for our monthly newsletter, you will also receive the newest application notes where our products are being used and many other resources such as white papers, videos, technical articles and new product information.

Home | About CAS | Policies | Distributor Login | Systems Integrators

©2011 Computer Aided Solutions, LLC.