EL-DataPad Data Collector

EL-DataPad Hand Held Data Collector & Programmer

Product Overview
  • Collects and stores data from at least 500 data loggers
  • Full or quick set-up of compatible EasyLog USB data
  • Touch screen interface for navigation of menus
  • Stored data can be transferred to a PC/Mac via micro USB cable
  • Integral rechargeable lithium battery provides up to 8 hours use
Useful Links
El-DataPad Data Collector


Manufacturer - Lascar

Model Number - EL-DataPad

Product Spec Sheet




Features

  • Collects and stores data from at least 500 data loggers
  • View downloaded data with general trend and summary screens
  • Allows full or quick set-up of compatible EasyLog USB data loggers
  • Touch screen interface for navigation of menus
  • 2.8” TFT display
  • Stored data can be transferred to a PC/Mac via micro USB cable
  • Use Lascar’s EasyLog USB software on a PC to graph data and export to Excel
  • Integral rechargeable lithium battery provides up to 8 hours use (nominal)

The EL-DataPad allows users of Lascar’s EL-USB data loggers to configure their units and download data and view logging results on-thespot rather than removing the logger from the environment being measured and taking it to their PC. This allows continual logging with shorter breaks in data collection, less travel for the user, on-site data collection in graph, legend and summary format and the ability for users to reconfigure loggers in ‘the field’.

The logger is connected to the EL-DataPad via a standard USB port at the top of the viewer. Once connected, the user is guided through a simple touchscreen menu with options to Set-Up Logger, Stop Logger & Download and View Data. On-screen instructions follow the same structure as Lascar’s EL-USB-WIN software for PC currently provided with each data logger.

Data from up to 100 loggers can be viewed on the EL-DataPad, with data from a further 400 units stored on the unit at any one time. Data can be transferred to a PC or Mac using a micro USB cable supplied with the unit. Once uploaded, data is saved in comma separated variable (csv) format, making it suitable for import into spreadsheet packages such as Microsoft Excel or graphed on a PC using Lascar’s EL-WIN-USB software .

The EL-DataPad is compatible with the following EL-USB data loggers: EL-USB-1, EL-USB-1-LCD, EL-USB-1-PRO, EL-USB-2, EL-USB-2+, EL-USB-2-LCD, EL-USB-2-LCD+, EL-USB-TC, EL-USB-TC-LCD, EL-USB-LITE.

Hardware

  • Battery: Lithium Polymer, rechargeable via micro-USB connection.
  • LCD: 240x320 2.8” TFT with touch-screen.
  • Internal Flash memory.
  • Single front-panel push-button used for power-switch. Single press=ON, press & hold for 3 sec = OFF.
  • 1x USB Type A socket (top of unit) for connection of Lascar data loggers.
  • 1x micro-USB (bottom of unit) for connection of unit to PC via 1m
  • USB cable supplied

By pressing on the Set-Up Logger icon shown above, users can name their data logger, select a sample rate, set high and low alarms and choose the logging start time. Simply press the green icon and follow the on-screen instructions.

Connect the data logger to the EL-DataPad, press the red arrow and follow the on-screen instructions.

The EL-DataPad enables you to view graphical data that is stored in memory. To view data, press the blue graph icon and select the file you wish to view by following the on-screen instructions.

Application Notes

Below features our collection of application notes and case studies involving this product.

Monitoring Milk Deliveries in Transit to Supermarkets

Request Pricing & Information

If you need information right away or prefer to speak with a person, call us and one of our Experienced Applications Engineers will be happy to talk with you. You can reach us at 1-800-956-4437 during our normal business hours Monday - Friday from 8am to 6pm (EDT).

After filling out the form below, an applications engineer will contact you within at least one business day.

Indicates a required field.

Fields that are not required are recommended to be filled out so that we can better assist you.

Request Form

Name Address 1
Email Address 2
Phone # City
Company State
Job Title Zip
Fax # Country
Product(s)

of Interest
Application
Additional

Information
Human Verification What is the next number after 7?  
Newsletter Sign Up - Here at CAS Data Loggers we are constantly publishing new articles, and now you can receive monthly emails to see what's new. By signing up for our monthly newsletter, you will also receive the newest application notes where our products are being used and many other resources such as white papers, videos, technical articles and new product information.

Home | About CAS | Policies | Distributor Login | Systems Integrators

©2011 Computer Aided Solutions, LLC.