Data Loggers For All Applications
Data Loggers for All Applications
1 - 800 - 956 - 4437
M-Th 8A-5:30P(EDT)
Fri     8A-4:30P(EDT)
Find a data logger by selecting an application from the list below.
Request Pricing & Information
Home -> Lascar -> EL-USB-1-RCG USB Temperature Data Logger

EL-USB-1-RCG USB Temperature Data Logger

Rechargeable Battery

Product Overview
  • -20 to +60°C (-4 to +140°F) measurement range
  • Environmental protection to IP67
  • Rechargeable lithium-ion battery
  • Bi-colour status LEDs behind protective glass window
  • Supplied with Type A to Mini B USB cable
  • 32,510 temperature readings
EL-USB-1-RCG Temperature Data Logger


Manufacturer - Lascar

Model Number - EL-USB-1-RCG

Product Spec Sheet

Rechargable Temperature Data Logger with USB Interface


This standalone data logger measures and stores up to 32,510 temperature readings over a -20 to +60° (-4 to +140°F) measurement range. The polycarbonate window and stainless steel 316 assembly provide protection from corrosion, impact and water ingree to IP67 / NEMA 4X. The unit is powered by a lithium-ion recharable battery which allows logging for up to 1 month. Setup and downloading is completed by connecting the data logger to a PC's USB port using the supplied cable and running the purpose designed software under Windows 2000, XP, Vista and Windows 7. Correct functioning of the unit is indicated by flashing red and green LEDs. Downloaded data can then be graphed, printed and exported to other applications.

LED Status Indication


EL-USB-1-RCG features two LEDs that indicate the logging, battery and alarm status:

  • The first LED flashes red (R) to indicate that the EL-USB-1-RCG is in an alarm condition. It will flash when the logged temperature has exceeded a Low or High alarm level.
  • The second LEd flashes green (G) to indicate that the EL-USB-1-RCG is not in an alarm condition. Latching is enabled by default, which forces the logger to continue flashing the red LED after an alarm, even when the temperature has returned to normal. This feature ensures that the user is notified than an alarm level has been exceeded, without the need to download the data from the logger.

Latching can be turned off via the control software. The red LED will then only flash whilst the logger is in an alarm condition. When the temperature returns to normal, the green LED will flash.

Additional LED modes are explained below:

Battery Charging


The logger is fitted with a 280mAh capacitiy (nominal) rechareable Lithium-Ion battery. The logger must be connected to an active USB port to recharge the battery; this may take up to 5 hours, depending on the level of discharge. The battery charge status is indicated by the status LED's. The red LED indicates that chargin is ongoing; the green LED indicates that the battery has a full charge.

Like all rechargeable batteries, the fully charged capacity reduces over time. The battery operates best at temperatures of 10°C to 30°C (50°F to 86°F). Recharing should only be performed within this temperature range.

Specifications Minimum Typical Maximum Unit
Measurement range -20 (-4) +60 (+140) °C (°F)
Internal resolution 0.1(0.2) °C (°F)
Accuracy (overall error) ±1 (±2) °C (°F)
Logging rate every 1s every 12 hr -
Recharing time 5 Hours -
Operating temperature range -20 (-4) +60 (+140) °C (°F)
Charging temperature range +10 (+50) +20 (+68) +30 (+86) °C (°F)
Lithium Battery Life 1* 4** Year

* @-20°C(-4°F), 1 second logging rate
** @-20°C(68°F), 1 minutes logging rate

Dimmensions


All dimmensions are in mm (inches)

EasyLog Software


The core of Lascar's data logging solution is the free software supplied with each data logger. Using a wizard format to guide the user through setup of the data logger and subsequent download of collected data, the software puts the 'easy' into EasyLog.

Video Demonstrations of EasyLog Software


How to setup an EL-USB data logger

Downloading data demonstration





Features

  • Collects and stores data from at least 500 data loggers
  • View downloaded data with general trend and summary screens
  • Allows full or quick set-up of compatible EasyLog USB data loggers
  • Touch screen interface for navigation of menus
  • 2.8” TFT display
  • Stored data can be transferred to a PC/Mac via micro USB cable
  • Use Lascar’s EasyLog USB software on a PC to graph data and export to Excel
  • Integral rechargeable lithium battery provides up to 8 hours use (nominal)

The EL-DataPad allows users of Lascar’s EL-USB data loggers to configure their units and download data and view logging results on-thespot rather than removing the logger from the environment being measured and taking it to their PC. This allows continual logging with shorter breaks in data collection, less travel for the user, on-site data collection in graph, legend and summary format and the ability for users to reconfigure loggers in ‘the field’.

The logger is connected to the EL-DataPad via a standard USB port at the top of the viewer. Once connected, the user is guided through a simple touchscreen menu with options to Set-Up Logger, Stop Logger & Download and View Data. On-screen instructions follow the same structure as Lascar’s EL-USB-WIN software for PC currently provided with each data logger.

Data from up to 100 loggers can be viewed on the EL-DataPad, with data from a further 400 units stored on the unit at any one time. Data can be transferred to a PC or Mac using a micro USB cable supplied with the unit. Once uploaded, data is saved in comma separated variable (csv) format, making it suitable for import into spreadsheet packages such as Microsoft Excel or graphed on a PC using Lascar’s EL-WIN-USB software .

The EL-DataPad is compatible with the following EL-USB data loggers: EL-USB-1, EL-USB-1-LCD, EL-USB-1-PRO, EL-USB-2, EL-USB-2+, EL-USB-2-LCD, EL-USB-2-LCD+, EL-USB-TC, EL-USB-TC-LCD, EL-USB-LITE.

Hardware

  • Battery: Lithium Polymer, rechargeable via micro-USB connection.
  • LCD: 240x320 2.8” TFT with touch-screen.
  • Internal Flash memory.
  • Single front-panel push-button used for power-switch. Single press=ON, press & hold for 3 sec = OFF.
  • 1x USB Type A socket (top of unit) for connection of Lascar data loggers.
  • 1x micro-USB (bottom of unit) for connection of unit to PC via 1m
  • USB cable supplied

By pressing on the Set-Up Logger icon shown above, users can name their data logger, select a sample rate, set high and low alarms and choose the logging start time. Simply press the green icon and follow the on-screen instructions.

Connect the data logger to the EL-DataPad, press the red arrow and follow the on-screen instructions.

The EL-DataPad enables you to view graphical data that is stored in memory. To view data, press the blue graph icon and select the file you wish to view by following the on-screen instructions.

Request Pricing & Information

If you need information right away or prefer to speak with a person, call us and one of our Experienced Applications Engineers will be happy to talk with you. You can reach us at 1-800-956-4437 during our normal business hours Monday - Friday from 8am to 6pm (EDT).

After filling out the form below, an applications engineer will contact you within at least one business day.

Indicates a required field.

Fields that are not required are recommended to be filled out so that we can better assist you.

Request Form

Name Address 1
Email Address 2
Phone # City
Company State
Job Title Zip
Fax # Country
Product(s)

of Interest
Application
Additional

Information
Human Verification What is the next number after 1?  
Newsletter Sign Up - Here at CAS Data Loggers we are constantly publishing new articles, and now you can receive monthly emails to see what's new. By signing up for our monthly newsletter, you will also receive the newest application notes where our products are being used and many other resources such as white papers, videos, technical articles and new product information.

Home | About CAS | Policies | Distributor Login | Systems Integrators

©2011 Computer Aided Solutions, LLC.