OMK610 Oven Temperature Profile Data Logger
Complete Oven Profiling Kit
|
Product Overview
Useful Links
|
OMK610 - paint over profiling system
Everything you need for paint oven temperature profiling and paint cure calculations in one easy to use and convenient system. Having over 40 years experience in the manufacture of oven recorders for the coatings industry, Grant has designed the latest version of the OMK610 kit to boast many new features to assist in production quality control and reducing operating costs.
- Direct report print out from the logger – no PC required in production
- New enhanced thermal barrier giving maximum protection – now available with a heat absorbing insert
- New fast response probes for both air and surface temperature
- PaintView data storage, report generation and analysis included
- Up to 6 temperature channels, storing up to 250,000 readings
The OMK610 kit comprises of an OQ610 data logger, PaintView software, thermal barrier, carry case and a quick start guide. A choice of temperature probes available additionally.
Benefits of using the OMK610 kit:
- Meets paint manufacturers’ specified cure parameters
- Maintains a specified level of cure ensuring repeatable quality
- Maximises oven usage and throughput
- Optimises oven running (energy) costs
- Archives data and results as part of any quality control system or supplier audit trail
- Line operators can use it without the need for a PC
OMK610 kit comprises of:
- OQ610 data logger
- PaintView software
- Thermal barrier
- Carry case
- Quick start guide
- USB cable
- Set of batterie
Stainless steel thermal barrier
Thermal barriers are insulated containers designed to keep heat out so that the Squirrel data logger inside remains at a safe operation temperature for a specified duration. Grant offers a wide range of thermal barriers with different time/temperature specifications.
- Provides protection to Squirrel data loggers when used in high temperature oven profiling applications (static or conveyor)
- A range of standard and customised models with different performance characteristics
- Made from stainless steel, for years of use
- Barriers available for very high temperature applications – manufactured to order
- Suitable for applications in food, powder coating, stove enamelling, ceramic, kiln and furnace
- Can be constructed using special phase change material for added protection for very high temperature applications.
| New Barrier with Phases Change Heat Sink | without Heat Sink | ||||||||
| Temp °C | 100 | 150 | 200 | 250 | 300 | 100 | 150 | 200 | 250 |
| Duration (mins) | 340 | 195 | 130 | 100 | 30 | 140 | 80 | 60 | 50 |
| Size | 245 x 245 x 115 (l x w x h) | ||||||||
| Weight | 6Kg | 4Kg | |||||||
OMK610 Kit Features
- The Squirrel OQ610 can record up to eight readings per second from each sensor and store over 260,000 readings in its memory
- Small, robust thermal barrier can now accept a stainless steel heat sink, which greatly extends the system performance (TB610HS)
- At the end of the recording run, data is downloaded directly to printer or to PC for analysis and reporting using PaintView software
- At the touch of a button, the OQ610 can directly print user-configurable, concise reports to simplify record keeping and provide ISO9000 quality records
- Up to 6 K-Type temperature probes can be connected to the logger. These probes can be clipped on to non-magnetic components or via a magnet
- Configure the OQ610 logger for all oven applications
- Clear Multilanguage LCD screen indicates cure % at the end of the cycle (English, German, French, Spanish and Italian)
- USB On The Go – the logger can print out a concise, graphical report of each run directly via USB, without the need for a PC
- Create paint cure data libraries (by manufacturer and / or paint type)
- Set optimised cure temperature curves with upper and lower limits
- Create graphical and statistical data reports via the Report Wizard, incorporating company logos and JPEG photographs
PaintView Software for OMK 610 paint oven profiling system
PaintView is an easy to use software package designed for exclusive use in the paint and finishing industry and is included FREE with every OQ610 temperature logger. It enables easy setup of your logger and automatic download of your data from the logger into a meaningful measure of paint cure. For advanced paint cure calculations, it can also provide rapid interpretation of results. PaintView also gives you the additional benefits of graphically analysing your historical and on-line data, along with advanced reporting.
Key Features
- User friendly spreadsheet style software for exclusive use in paint curing applications
- PaintView offers the choice of the Grant 'classic' cure and area integration cure analysis methods
- A database can be built of different paint types from various paint manufacturers
- USPaintView provides zones for optimal paint solving in your process
- With regular usage the software can pinpoint any uneven temperatures within the stoving process
- The tolerance curve feature gives the ability to draw your ideal curve and check that your data fits
- Easily view and control the logger status from one single screen
- Security function protects your data and setup configurations
- The graphing feature within the software offers fully annotated curves, zoom and cursor scrolling analysis
- All settings can be saved for reuse
- The report generator can provide standard reports on all functions of the curing process to provide your customers with proof of compliance to their stoving requiremen
- Export data into Excel™ or as a CSV file for customisable data analysis
|
|
OMK610 Kit Specifications
| Accuracy | -50 to 500°C - ± 0.5°C -200 to 1300°C - ± 1.0°C |
| Resolution | 0.1° |
| Sampling rate | Fastest: eight times per second per channel Slowest: once every two hours per channel |
| Channel | 6 K or T type thermocouples |
| Temperature measuring range | 200°C to 1300°C (K type) -200°C to 400°C (T type) |
| Operating environment | Temperature range -30 to 65°C Humidity 95% |
| Memory | Flash memory of 260,000 readings |
| Maximum runs stored | 8 |
| Communication | USB 1.1 and 2.0 compatible |
| Display | Alphanumeric display of 2 x 16 characters shows pass/fail, battery status, probes connected, real time readings and communication to printer or P |
| Power supply | Two AA cells to give 200 hours operation at default settings |
| Dimensions and weight (l x w x h), g | 148 mm x 95 mm x 21 mm, 450 |
Request Pricing & Information
If you need information right away or prefer to speak with a person, call us and one of our Experienced Applications Engineers will be happy to talk with you. You can reach us at 1-800-956-4437 during our normal business hours Monday - Friday from 8am to 6pm (EDT).
After filling out the form below, an applications engineer will contact you within at least one business day.
* Indicates a required field.
Fields that are not required are recommended to be filled out so that we can better assist you.


