Data Loggers For All Applications
Data Loggers for All Applications
1 - 800 - 956 - 4437
Monday - Friday
8am - 6pm (EDT)
Find a data logger by selecting an application from the list below.
Request Pricing & Information
Home -> Lascar -> EL-USB-3 USB Voltage Data Logger

EL-USB-3 USB Voltage Data Logger

Product Overview
  • 0-30V d.c. measurement range
  • Logging rates between 1s and 12hr
  • Store 32,510 readings
  • Connection via two screw terminals
  • USB interface for set-up and data download
  • User-programmable alarm thresholds
  • Status indication via red and green LEDs
  • Supplied with replaceable internal lithium battery and Windows control software
EL-USB-3 USB Voltage Data Logger


Manufacturer - Lascar

Model Number - EL-USB-3

Product Spec Sheet

Voltage USB Data Logger


This standalone data logger measures and stores up to 32,510 voltage readings over a 0-30V d.c. measurement range. The user can easily set up the logging rate and start time, and download the stored stat by plugging the data logger into a PC's USB port and running the purpose designed software under Windows 2000, XP, Vista & 7. The data can then be graphed, printed and exported to other applications. The data logger is supplied complete with a long-life lithium battery. Correct functioning of the unit is indicated by flashing red and green LEDs. The data logger features a pair of screw terminals and is supplied complete with a set of measurement leads terminating in crocodile clips.

LED Flashing Modes


EL-USB-3 features a red and a green LED

By default hold is diabled. In this mode the red LED will no longer continue to flash after the logged reading has treturned to normal from an alarm condition.

Hold can be turned on via the control software. In this mode the red LED that indicates an alarm condition will continue to flash, even after the logged reading has returned to normal. This feature ensures that the user is notified that an alarm level has been exceeded, without the need to download the data from the logger.

Specifications Minimum Typical Maximum Unit
0-30V d.c. measurement range 0 30 V d.c.
Internal resolution 50 mV d.c.
Accuracy (overall error) ±1 %
Logging rate every 1s every 12 hr -
Operating temperature range -35 (-31) +80 (+176) °C (°F)
1/2AA 3.6V Lithium Battery Life 1* Year

* depending on ambient temperature, logging rate and use of alarm LED.

Dimensions


All dimensions in mm(inches)

Connection and Applications


EasyLog Software


The core of Lascar's data logging solution is the free software supplied with each data logger. Using a wizard format to guide the user through setup of the data logger and subsequent download of collected data, the software puts the 'easy' into EasyLog.

Video Demonstrations of EasyLog Software


How to setup an EL-USB data logger

Downloading data demonstration





Features

  • Collects and stores data from at least 500 data loggers
  • View downloaded data with general trend and summary screens
  • Allows full or quick set-up of compatible EasyLog USB data loggers
  • Touch screen interface for navigation of menus
  • 2.8” TFT display
  • Stored data can be transferred to a PC/Mac via micro USB cable
  • Use Lascar’s EasyLog USB software on a PC to graph data and export to Excel
  • Integral rechargeable lithium battery provides up to 8 hours use (nominal)

The EL-DataPad allows users of Lascar’s EL-USB data loggers to configure their units and download data and view logging results on-thespot rather than removing the logger from the environment being measured and taking it to their PC. This allows continual logging with shorter breaks in data collection, less travel for the user, on-site data collection in graph, legend and summary format and the ability for users to reconfigure loggers in ‘the field’.

The logger is connected to the EL-DataPad via a standard USB port at the top of the viewer. Once connected, the user is guided through a simple touchscreen menu with options to Set-Up Logger, Stop Logger & Download and View Data. On-screen instructions follow the same structure as Lascar’s EL-USB-WIN software for PC currently provided with each data logger.

Data from up to 100 loggers can be viewed on the EL-DataPad, with data from a further 400 units stored on the unit at any one time. Data can be transferred to a PC or Mac using a micro USB cable supplied with the unit. Once uploaded, data is saved in comma separated variable (csv) format, making it suitable for import into spreadsheet packages such as Microsoft Excel or graphed on a PC using Lascar’s EL-WIN-USB software .

The EL-DataPad is compatible with the following EL-USB data loggers: EL-USB-1, EL-USB-1-LCD, EL-USB-1-PRO, EL-USB-2, EL-USB-2+, EL-USB-2-LCD, EL-USB-2-LCD+, EL-USB-TC, EL-USB-TC-LCD, EL-USB-LITE.

Hardware

  • Battery: Lithium Polymer, rechargeable via micro-USB connection.
  • LCD: 240x320 2.8” TFT with touch-screen.
  • Internal Flash memory.
  • Single front-panel push-button used for power-switch. Single press=ON, press & hold for 3 sec = OFF.
  • 1x USB Type A socket (top of unit) for connection of Lascar data loggers.
  • 1x micro-USB (bottom of unit) for connection of unit to PC via 1m
  • USB cable supplied

By pressing on the Set-Up Logger icon shown above, users can name their data logger, select a sample rate, set high and low alarms and choose the logging start time. Simply press the green icon and follow the on-screen instructions.

Connect the data logger to the EL-DataPad, press the red arrow and follow the on-screen instructions.

The EL-DataPad enables you to view graphical data that is stored in memory. To view data, press the blue graph icon and select the file you wish to view by following the on-screen instructions.

Request Pricing & Information

If you need information right away or prefer to speak with a person, call us and one of our Experienced Applications Engineers will be happy to talk with you. You can reach us at 1-800-956-4437 during our normal business hours Monday - Friday from 8am to 6pm (EDT).

After filling out the form below, an applications engineer will contact you within at least one business day.

Indicates a required field.

Fields that are not required are recommended to be filled out so that we can better assist you.

Request Form

Name Address 1
Email Address 2
Phone # City
Company State
Job Title Zip
Fax # Country
Product(s)

of Interest
Application
Additional

Information
Human Verification What is the next number after 5?  
Newsletter Sign Up - Here at CAS Data Loggers we are constantly publishing new articles, and now you can receive monthly emails to see what's new. By signing up for our monthly newsletter, you will also receive the newest application notes where our products are being used and many other resources such as white papers, videos, technical articles and new product information.

Home | About CAS | Policies | Distributor Login | Systems Integrators

©2011 Computer Aided Solutions, LLC.