RTR-505-Pt Wireless RTD Data Logger
Supports RTD Sensor Types
|
Product Overview
Description RTR-505-Pt is a Data Logger which supports Pt100 (3-wire / 4-wire) and Pt1000 (3-wire / 4-wire) sensors. |
Download Data via Wireless Communication with a Base Unit
Recorded data can be downloaded from the RTR-505 data logger (Remote Unit) via wireless communication with a Base Unit. The wireless communication range between a Remote Unit and a Base Unit is about 150 meters [500 ft]. By registering an RTR-500 as a Repeater, it can be used to expand the wireless communication range.
Large Logging Capacity: Up to 16,000 Readings
16,000 readings means you can record every one second and still log four and a half hours of data; or at a recording interval * of 60 minutes you can keep logging for 666 days. A Base Unit can download via wireless communication one RTR-505 Remote Unit at full logging capacity (16,000 readings) in about two minutes.
Low Energy Consumption Design
The RTR-505 Data Logger uses one Lithium Battery (LS14250). At normal temperature, if recorded data is downloaded once a day or if monitoring is carried out once every ten minutes, the estimated battery life will be about ten months. Model names which include “L” are designed with a large capacity battery pack. Under the same conditions, L-type models will continue for about four years without the need to change the battery.
Battery life varies depending upon the type of battery, the measuring environment, and the frequency of communication. All estimates are based on operations carried out with a new battery and are in no way a guarantee of actual battery life.
Applications
- For temperature recording of cooking equipment such as pans, fryers, and ovens
- For temperature management of refrigerated and frozen goods
- Managing temperature for blood transport

Measurement with a Variety of Sensors
The RTR-505 allows for a variety of commercially available sensors to be connected to the included Input Module. This new flexibility has widened the range of possible applications without having to change Base Units.

Possible to Adjust Measurements
It is possible to make adjustments to measurements for each RTR-500 Series Remote Unit by using the exclusive application "Adjustment Tools".
|
|
RTR-500GSM Cellular Base StationThis base unit comes with a built in GSM Modem for Wireless Communication.
|
|
|
RTR-500 USB Base Station/RepeaterThe RTR-500 can be used as either a “Base Unit” for the RTR-500 Wireless Data Logger Series or a “Repeater” for extending wireless communication range.
|
|
|
RTR-500NW Network Data CollectorThe RTR-500NW Network Base Station for the TandD RTR-500 Series of wireless data loggers is used to gather data and alarms from multiple data loggers via a proprietary wireless interface and then relay it to a Ethernet based LAN. The RTR-500NW has a 100BaseT Ethernet interface for connection into the local network.
|
|
|
RTR-500AW Network Data CollectorThe RTR-500AW Network Base Station for the TandD RTR-500 Series of wireless data loggers is used to gather data and alarms from multiple data loggers via a proprietary wireless interface and then relay it to a Ethernet based LAN.
|
|
|
RTR-500DC Wireless Handheld Data CollectorThe RTR-500DC can collect recorded data from Remote Units via wireless communication.
|
T&D WebStorage Service is an online service provided by T&D Corporation. By setting up any compatible products to transmit recorded data and current readings to our dedicated Internet server, Users can use the WebStorage Service to access and share data anytime from anywhere.
Free Online Service for Data Storage
Experience the convenience of sharing recorded data via the Internet! Perfect for processing and managing data recorded in remote places or for allowing several people to view the same recorded data at their convenience. Recorded data can be transmitted to T&D WebStorage Service from any of the compatible products.
The data transmitted to T&D WebStorage Service can be accessed via your browser from anywhere, anytime, as long as an internet connection is available.
Application Examples
One perfect example to show the system's unique power is the "Temperature Management of Products while in Transit".
Here, using RTR-500GSM as an example, T&D WebStorage Service enables the "Sender", the "Receiver", and the "Carrier" to monitor the same current readings graph and check the temperature condition of the products while in transit.
Access your Recorded Data and Current Readings anytime from anywhere and experience the greatness of the new T&D WebStorage Service!
Compatible Products
It is possible to set data transmission from the following T&D products to T&D WebStorage Service.
1: Antenna
2: LCD Display
3: Optical communication Area
4: Sensor Jack
5: Back Case
6: Large Capacity Battery
7: Polyamide (black)
8: Vinyl Chloride Coated Electrical Wire
9: M3.5 Crimp Terminal
| Measurement Items (*1) | Temperature (Pt100, Pt1000) |
| Unit of Measurement | °C, °F |
| Recording Intervals | Select from 15 choices: 1, 2, 5, 10, 15, 20, 30 sec. / 1, 2, 5, 10, 15, 20, 30, 60 min. |
| Logging Capacity | 16,000 readings |
| Recording Modes |
Endless: Upon reaching logging capacity, the oldest data is overwritten and recording continues. One Time: Recording automatically stops when logging capacity is full. * When using RTR-500NW or RTR-500AW as a Base Unit, only "Endless" can be selected. |
| LCD Displayed Items | Measurement, Recording Status, Recording Mode, Battery Life Warning, Unit of Measurement, Full (Logging Capacity FULL), Sensor Unconnected, Input Module Unconnected, Measurement Range Exceeded, Display Range Exceeded) |
| Power |
Lithium Battery LS14250 (*2) x 1 / Lithium Battery CR2 x 1 For L type: Large Capacity Battery Adaptor Kit (RTR-500B1 /sold separately) External Power Adaptor Kit (RTR-500A1 /sold separately) |
| Battery Life (*3) | About 10 months (for temperature measurement) About 4 years (for temperature measurement with L type) |
| Radio Standard Specifications | FCC Part15 Section247 / IC RSS-210 (Frequency Range: 902 to 928MHz) |
| Wireless Transmission Range | About 150 meters (500ft) if direct and unobstructed |
| Communication Interfaces | Wireless Communication / Optical Communication |
| Communication Time | When downloading one Remote Unit at full logging capacity Wireless Communication: about 2 min. Optical Communication: about 160 sec. |
| Waterproof Capacity | Splash proof (rated for use in daily life) (*4) |
| Dimensions | H62mm x W 47mm x D19mm (excluding protrusions and sensor) L type: D 46.5mm (with Large Capacity Battery Pack) Antenna length: 24mm |
| Weight | About 55g (including battery / excluding Input Module) L Type: about 109g (with Large Capacity Battery Pack) |
| Operating Environment | - 30 to 80°C (*5) (The operating temperature range and measurement range is -40 to 80°C but wireless communication cannot occur in an environment of less than -30°C.) |
| Other | A Base Unit is required separately. (Compatible Base Units: RTR-500, RTR-500NW, RTR-500AW) |
|
(*1) For information about measurement range, see the specifications of each Input Module in the Options Page.
(*2) The included lithium battery (LS14250) is not sold in stores. Please purchase the optional battery set for low-temperature use (TR-11P2) for replacement. (*3) Battery life varies depending upon the connected Input Module, measuring environment, frequency of communication, Unit settings, and battery performance. (*4) This is the waterproof capacity of a Unit with an Input Module connected. Note that sensor connector of the Input Module is not water resistant. (*5) If you are using a Data Logger in an environment where temperatures may be lower than -20°C or higher than 60°C, we strongly suggest purchasing and using the optional battery set for low-temperature use (TR-11P2) |
|
Software Packages
RTR-500 GSM for Windows- RTR-500GSM Settings Utility
- Temperature / Humidity Graph
- Adjustment Tools
- RTR-500W Settings Utility
- Temperature / Humidity Graph
- Multi-Scale Graph
- Data Download Tool
- Adjustment Tools
- RTR-500 Settings Utility
- RTR-500 for Windows
- Temperature / Humidity Graph
- Multi-Scale Graph
- Adjustment Tools
- RTR-500DC Settings Utility
- RTR-500DC Manager
- Temperature / Humidity Graph
- Multi-Scale Graph
- Data Download Tool
- Adjustment Tools
"Settings Utility" Program makes Settings a Snap!
The Settings Utility application is used to take care of all Base Unit settings and registration of Remote Units and Repeaters. After having registered and placed the Remote Units and Repeaters in the field, it is possible to run communication tests to check signal strength between the various units to ensure stable communication.
Easy-to-Understand Operation Guide
The Operation Guide that is part of the software uses easy to understand terms to help lead you through all the necessary steps and setting procedures. If during setup you get confused or have trouble, just simply open the Operation Guide in the same on-screen window and make settings while consulting the Guide.
Difficult Cellular Phone Network Settings made Easy
When using the RTR-500GSM, we have included an “Initial Settings Wizard” which guides you through what otherwise would be the difficult process of setting up the unit for GSM network communication; just put in the SIM Card and turn on the Wizard.
Intuitive User-Friendly Graph Tools (Temperature / Humidity Graph and Multi-Scale Graph)
With either program you can view up to eight channels of data in one graph.The Graph programs intuitive operation allows the User to easily hide or view channels, zoom in and out on data, switch back and forth from °C to °F, and view data in table form.
View in Table Form
Graph data can be easily viewed as a data list. The highest and lowest values are shown in easily distinguishable colors.
From Graph Editing to Data Analysis
It is possible to hide, re-order and delete channels, edit recording start times, and make changes to colors used for the graph scale lines, data lines and background. Also move the A and B cursor at the bottom of the graph to view data readings for those points and the calculated difference between the points.By saving graph data as CSV Format Text File data, that data can then be uploaded into common spreadsheet software for data analysis.
Remote Unit Adjustment Settings
When using multiple measuring devices, this function allows the user to correct for inaccuracies found in measured values when compared to a standard measurement (the value measured by the standard device). Measurements can be adjusted and recorded based on a standard measurement. The RTR-500 Series Software allows for adjustment settings to be made to Remote Unit measurements by simply selecting the adjustment method from either "1 Point Adjustment" or "2 Point Adjustment" and entering the values for "Before Adjustment” and "After Adjustment".
Wall Attachment (TR-05K3)
(1)Lock screws (2)Polycarbonate (3)Double-sided Adhesive tape
Dimension (mm):
W66.6 x H70 x D24.7
Screw Holes: 2 - Φ4.2
* NOTE: Cracks may develop if exposed to strong impact at temperature of -30°C or less.
External Power Adapter Kit (RTR-500A1)
Voltage Input: DC6V
Back-up Power: Ni-MH Battery (In case of power loss)
Back-up Time: 4 days (*1)
Charging Method: Trickle Charge
Operating Temperature: 0 to 60°C
Waterproof Capacity: None
Weight: about 37g (without AC Adaptor)
Kit Contents:
External Power Adaptor x 1
AC Adaptor (AD-0638 or AD-0638-C) x 1
Attachment hook x 1
Rubber Packing (small) x 1 (for AC Adaptor jack)
and Maintenance Set (TR-00P1)
(*1) Battery Life varies depending on measuring environment, recording interval, transmission frequency, and ambient temperature. The battery life estimated here is calculated using a new battery under normal operating conditions and in no way should be understood as a guarantee of battery life.
Large Capacity Battery Kit (RTR-500B1)
Power: Lithium Battery x 1 (LS26500) (*1)
Battery Life: about 4 years (*2)
Waterproof Capability: Splash proof
Operating Temperature: -40 to 80°C (*3)
Weight: about 75g (including Lithium Battery)
Kit Contents:
Large Capacity Battery Adaptor x 1
Attachment hook x 1
and Maintenance Set (TR-00P1)
(*1) When using RTR-500B1 it is necessary to purchase Lithium Battery (LS26500). For details, contact your local authorized distributor.
(*2) Battery Life varies depending on measuring environment, recording interval, transmission frequency, and ambient temperature. The battery life estimated here is calculated using a new battery under normal operating conditions and in no way should be understood as a guarantee of battery life.
(*3) Operating temperature depends on the specifications for the data logger being used.

Request Pricing & Information
If you need information right away or prefer to speak with a person, call us and one of our Experienced Applications Engineers will be happy to talk with you. You can reach us at 1-800-956-4437 during our normal business hours Monday - Friday from 8am to 6pm (EDT).
After filling out the form below, an applications engineer will contact you within at least one business day.
* Indicates a required field.
Fields that are not required are recommended to be filled out so that we can better assist you.