SQ2010 Portable Universal Input Data Logger
Grant SQ2010 Data Logger
|
Product Overview
Useful Links
|
A powerful portable data logger for everyday use
- Flexible
- Very easy to use
- Economical
- Handheld, ergonomic design
- USB connectivity with PC
- Ethernet or RS232 communications options available
- Extended battery life for unattended logging
The Squirrel 2010 is a versatile, general purpose logger, with 4 to 8 analogue input channels to measure current, voltage, resistance and temperature, plus 8 digital channels. All can be logged or used as triggers to automatically start or stop logging.
It is a compact, portable logger which is also suitable for bench based and fixed installations. Easily programmed via the four integral push buttons and large graphical display and with a basic accuracy of 0.1%, the Squirrel 2010 is able to fulfil many routine data logging needs, including more demanding applications requiring up to 10 readings per second on one channel.
Analogue inputs supported
- Thermistors
- Thermocouples
- Voltage
- Current
- Resistance
The Squirrel 2010 series comprises of two versions
SQ2010
Includes the following;
- Fitted Foam Lined Case
- SquirrelView Software
- Getting Started Guide including Certificate of Conformity
- USB connection cable
- Full set of Connection Plugs complete with Cable Ties
- Pack of 4 Precision Resistors for 4-20mA connection
- Set of C type Batteries
- Small Electrical Screwdriver
SQ2010 Kit
Includes all of the above, plus the following items;
- SquirrelView Plus Software
- Universal Mains Power Adaptor (110-240 Vac)
1. Easy to use, removable connector system
2. 4 to 8 universal analogue inputs (4 differential, 8 single ended) for recording temperature, current, voltage and resistance
3. Power output for sensor excitation/external devices
4. USB connectivity for quick and easy PC communication
5. Power supply – internal alkaline batteries, external DC power supply or via USB
6. RS232 or Ethernet communications – for modem or network connections
7. Range of trigger functions via 8 digital inputs; 2 pulse rate / counter inputs; 2 alarm / relay outputs
1. Use the four integral push buttons and graphical display to configure the logger – no PC required for operation
2. Display of real-time readings on the large clear graphical display
- Icon driven software and large clear graphical display for easy logger set-up and configuration
- Store up to 6 logger configurations in the onboard memory
- Use the convenient free SquirrelView set-up and download software to export stored data to your application
SquirrelView & SquirrelView Plus Sofware
SquirrelView is a universal software package that is included with every new Grant Squirrel data logger.
Its intuitive, user friendly, spreadsheet style interface allows quick set-up of the data logger for any application, speedy download of data and direct export to Excel™. SquirrelView Plus gives additional benefits such as graphical data analyses and advanced reporting options.
Minimum PC specification: – Windows® XP, Vista or Windows 7; Pentium II 266MHz; 60Mb hard disk space and 1 CD drive, colour SVGA screen (1024x768 recommended), at least one RS232 or one USB port, mouse.
Key feature
- Intuitive, user friendly spreadsheet style setup allows quick logger configuration in any application
- Flexible data presentation allows you to quickly display and analyse real time or historical data as a line graph, bar chart or analogue gauge
- Graphical alarm and event identification lets you easily identify occurrences around specific analogue or digital events e.g. pump coming on
- Quick Graph function lets you quickly and easily view large data files
- Export data into Excel™ in real time, or as a CSV file for customisable data analysis
- Easily view and control the logger status from one single screen
- Use the simple communication wizard for hassle free working with modems, Ethernet, GSM, etc.
- Download data by date, time or events, saving time when working via modem or looking for specific data
- Save settings on the PC for efficient re-use
- Protect your data and set-up configurations with the security function
SquirrelView Plus-Analysis
SquirrelView Plus lets you quickly and easily analyse the data from your Squirrel data logger in a familiar Explorer™ style interface. Data can be displayed with 2 different auto scaling Y-axes. This is particularly useful when displaying widely varying data from different sensors on one graph. You can also zoom in on areas of interest, use a cursor to pick out exact values, times and dates, get a statistical summary of your data, set high and low alarm thresholds and, using the calculation function, you can create new virtual channels from existing channels.
SquirrelView Plus also incorporates a report generation facility, which allows you to create custom report templates consisting of a title page with descriptive text, headers and footers, graphs, tabular list of data, statistics and data logger setup information. Templates can be setup with any of these combinations and saves time when preparing similar presentations of data.
SquirrelView & SquirrelView Plus |
SquirrelView Plus Version only |
||||||||||||||
|
|
| No. of analogue channels | 8 single ended or 4 differential inputs |
| Channel expansion | No |
| Universal Input | Yes |
| Voltage Ranges; Differential and Single Ended | -6 to 25, -0.6 to 2.4, ±0.3V, -0.15 to 0.15, -0.075 to 0.075 -6 to 12, -6 to 6, -3 to 3, -0.6 to 1.2, -0.6 to 0.6 |
| Common mode | 25v |
| Current Ranges, Differential (Requires external 10R shunt) | 4 to 20mA, ±30mA |
| Thermocouple Ranges; Differential and Single Ended |
-200 to 1200°C, J-type -200 to 1372°C, K-type -200 to 1300°C, N-type -50 to 1768°C, R-type -50 to 1768°C, S-type -200 to 400°C, T-type |
| Resistance Ranges, all 2 wire | 0 to 1250R, 0 to 5000R 0 to 300000R, 0 to 20000R |
| Thermistor Ranges | -50 to 150°C, U & UU-type -50 to 150°C, Y-type -30 to 150, S-type |
| Pt100/1000, 2-wire | -200 to 850°C |
| Internal reference temperature | -50 to 150°C |
| Pulse Count Ranges | 0 to 100Hz (1 input) 0 to 64kHz (1 input) 0 to 16000000 Count |
| Digital State/Event Ranges | 8 state inputs or 1 x 8 bit binary |
| Digital/Alarm Outputs | 2 open drain FETs, 18V, 0.1A |
| A/D Resolution | 24 bit |
| Accuracy | 0.1% of range + 0.1% of reading |
| Clock Resolution/Accuracy | 1s/10ppm Normal Mode – each input sampled at a maximum rate of 1 reading per second. Double-speed (mains reject off) – one input can be sampled at 10 readings per second and all others are sampled at a maximum rate of 1 reading per second |
| No of Intervals | 4 |
| Data Scaling | Yes |
| Data Statistics | Yes from within SquirelView Plus PC software |
| Calculated Channels | Yes, up to 16 |
| Memory Internal | 16M (1 to 1.8 million readings) |
| Display/Keypad | 128*64 dot graphical display, 4 button keypad |
| Internal Battery | 2 C cells |
| Battery Life | Up to 5 days with continuous usage whilst sampling all channels once per second |
| External Power | Yes, 8 to 28V dc & USB when plugged in |
| Sensor Power Output | 5V at 50mA, external 8-28V at 100mA (when connected) |
| Networking | Via RS232 to Ethernet adaptor (Netport, part no. SQ20A801) |
| Modem Support | Via RS232 modem (GSM Modem, part no. SQ20A802) |
| Actions & Triggers | As SQ2020/40 although two alarm outputs |
| PC Setup | Yes, SquirrelView compatible |
| Front Panel Setup | Via 4 integral 4 keys. All essential functionality available via key pad e.g. channel configuration, start / stop logging etc. Other advanced functions e.g. calculated channels and channel descriptions are available via connection to a PC running SquirrelView |
| Stored setups | 6 |
| Third Party Programming | As 20xx driver suite allows |
| Operating temp | -20 to 65°C |
| Dimensions | W175 x D135 x H55mm, Weight 0.7kg |
Application Notes
Below features our collection of application notes and case studies involving this product.
Monitoring Infant Skin Temperatures for Research
Chocolate Processing at Kinnerton Confectionary
Squirrel Data Logger 'Clamps' Down on Sugar Loss
River Flow Monitoring With Remote Communications
Request Pricing & Information
If you need information right away or prefer to speak with a person, call us and one of our Experienced Applications Engineers will be happy to talk with you. You can reach us at 1-800-956-4437 during our normal business hours Monday - Friday from 8am to 6pm (EDT).
After filling out the form below, an applications engineer will contact you within at least one business day.
* Indicates a required field.
Fields that are not required are recommended to be filled out so that we can better assist you.