Data Loggers For All Applications
Data Loggers for All Applications
1 - 800 - 956 - 4437
Monday - Friday
8am - 6pm (EDT)
Find a data logger by selecting an application from the list below.
Request Pricing & Information
Home -> Grant Instruments  -> SQ2020-2F8-WiFi Portable Wireless Universal Input Data Logger

SQ2020-2F8-WiFi Portable Wireless Universal Input Data Logger

Wireless 8/16 Channel Data Logger with 100Hz Sampling

Product Overview
  • Fully configurable via the integrated keypad
  • 128*97 dot graphical LCD display
  • Compatible with B, C, D type thermocouples
  • Integral Wi-Fi Ethernet networking
  • High precision (0.05%)
  • Advanced data management to MMC/SD card or PC
  • Flexible communications (USB, Ethernet, RS232)
  • High speed 100Hz on two channels
Useful Links
Grant SQ2020 WiFi Data Logger


Manufacturer - Grant Instruments

Model Number - SQ2020-2F8-WIFI

Product Spec Sheet

Powerful data loggers for all wireless applications

The Squirrel SQ2020 Wi-Fi hand held data logger combines high performance and universal inputs with the simplicity of Wi-Fi networking in a compact and easy-to-use instrument.

Using high accuracy, 24-bit analogue to digital converters, removable memory and Wi-Fi wireless Ethernet networking, the SQ2020 Wi-Fi is the ideal data logger for industrial, scientific research and quality assurance applications. Together with our comprehensive suite of software, SquirrelView, the SQ2020 provides standalone data acquisition, simple Wi-Fi networking, real-time metering and data analysis straight out-of-the-box.

Key Features

  • 8 true differential or 16 single ended universal analogue inputs for voltage, current or resistance measurements plus 2 high voltage, 4 pulse and 8 digital event/state inputs
  • Analogue inputs can be used with thermistors, thermocouples, 2, 3 or 4 wire RTD temperature sensors and 4-20mA signals
  • Logging rates of up to 100Hz on up to two channels
  • Large non-volatile internal memory storage for up to 14 million readings
  • Download of internal data to removable MMC/SD (Multi Media Card / Secure Digital) memory
  • Sensor power and FET outputs for use with external devices
  • Easy to read LCD and simple 4 button user interface
  • Up to 16 calculated / derived channels may be created using mathematical functions

Analogue inputs supported

  • Thermistors
  • Thermocouples
  • Pt100/Pt1000 (maximum of four 3 or 4-wire Pt100/1000 sensors)
  • Voltage
  • Current
  • Resistance

1. 8 to 16 universal analogue inputs for recording temperature, current, voltage and resistance
2. Easy to use, removable connector system
3. Power output for sensor excitation / external devices
4. 2 high voltage channels (up to 60V) for automotive applications
5. USB, Wireless Ethernet and RS232 connectivity for quick and easy PC and remote communication and Wi-Fi networking
6. Power supply – internal alkaline batteries or external DC power supply
7. Up to 8 digital and 4 pulse rate / counter inputs. Can be logged or used as triggers

  • 4 alarm outputs for triggering external devices

1. To operate the logger simply use the four integral push buttons and display, or use the convenient SquirrelView set-up, download and export software – free with every Squirrel logger
2. Large, clear 128*64 dot graphical LCD screen for easy access to readings and set-up information
3. Robust, ergonomically designed case with easy access to all user facilities

  • Store up to 1.8 million readings in the Squirrel’s onboard memory
  • Store up to 6 logger configurations. Load from a removable MMC / SD card for speed and convenience, or download data files to the card

SquirrelView & SquirrelView Plus Sofware

SquirrelView is a universal software package that is included with every new Grant Squirrel data logger.

Its intuitive, user friendly, spreadsheet style interface allows quick set-up of the data logger for any application, speedy download of data and direct export to Excel™. SquirrelView Plus gives additional benefits such as graphical data analyses and advanced reporting options.

Minimum PC specification: – Windows® XP, Vista or Windows 7; Pentium II 266MHz; 60Mb hard disk space and 1 CD drive, colour SVGA screen (1024x768 recommended), at least one RS232 or one USB port, mouse.

Key feature

  • Intuitive, user friendly spreadsheet style setup allows quick logger configuration in any application
  • Flexible data presentation allows you to quickly display and analyse real time or historical
  • data as a line graph, bar chart or analogue gauge
  • Graphical alarm and event identification lets you easily identify occurrences around specific analogue or digital events e.g. pump coming on
  • Quick Graph function lets you quickly and easily view large data files
  • Export data into Excel™ in real time, or as a CSV file for customisable data analysis
  • Easily view and control the logger status from one single screen
  • Use the simple communication wizard for hassle free working with modems, Ethernet, GSM, etc.
  • Download data by date, time or events, saving time when working via modem or looking for specific data
  • Save settings on the PC for efficient re-use
  • Protect your data and set-up configurations with the security function

SquirrelView Plus-Analysis

SquirrelView Plus lets you quickly and easily analyse the data from your Squirrel data logger in a familiar Explorer™ style interface. Data can be displayed with 2 different auto scaling Y-axes. This is particularly useful when displaying widely varying data from different sensors on one graph. You can also zoom in on areas of interest, use a cursor to pick out exact values, times and dates, get a statistical summary of your data, set high and low alarm thresholds and, using the calculation function, you can create new virtual channels from existing channels.

SquirrelView Plus also incorporates a report generation facility, which allows you to create custom report templates consisting of a title page with descriptive text, headers and footers, graphs, tabular list of data, statistics and data logger setup information. Templates can be setup with any of these combinations and saves time when preparing similar presentations of data.

SquirrelView & SquirrelView Plus

SquirrelView Plus Version only

Setup
  • Setup can be verified before it is sent to the logger
  • Converts setup files from previous Setwise software to SquirrelView
  • Hide facility allows you to tailor setup interface to your own requirements
  • Print setup information
Meter Mode
  • Displays up to 16 channels in real time
  • 3 Plot types: line graphs, gauges & dials
  • Auto scaling of Y axis
  • Value readout at cursor position
  • Saves metered data for re-use in other software
  • packages
  • Graph printout facility
  • Graph can be presented in various style
Download
  • Download directly as a CSV file
  • Download straight to a graph
  • Download by date & time (SQ20xx only)
  • Data downloader application ( SQ2010, SQ2020, 2040 series
Export
  • Easy to use export wizard
  • Customisable data export for Excel™, Lotus™ or other applications
  • Export viewer allows quick view facility of data
Additional Features
  • Tips of the day - provides informative shortcuts
  • Logger diagnostics
  • Security feature enables password setup
  • Communication wizard enables easy setup of USB (20xx only), RS232, Ethernet and Modem, Wi-Fi ( WiFi models only)
  • Interactive Help
  • Spanish and German versions availabl
Analysis
  • Easy analysis for: SQ20xx, SQ400/800,SQ1000, SQ1600, SQ1200/1250 and 600 series loggers
  • Easy to use Explorer style interface
  • Fully configurable data views
  • Creation of templates
  • Flexibility for customisable reports
  • Facility to include text comments with graphs
  • Flexible zoom feature including X and Y axis
  • Statistics calculator
  • Auto scaling of Y axis
  • Value readout at cursor position
  • Set and view high and low level thresholds
  • Customisable report facility: prints out graphs, readings,etc
  • Tolerance curve
  • Calculated channels
  • User notes
  • Archives
  • File convertor from Setwise and Squirrelwise
  • Product cure calculation
  • Display oven profiles and oven zones
  • Append/add data files
  • Import CSV file
Minimum Computer Requirements
  • Microsoft Windows XP™, Vista™ or Windows 7™
  • Pentium II 266 MHz
  • RAM as specified by PC operating system
  • 60 Mb hard disk space and 1 CD drive
  • Colour SVGA monitor running at 800 x 600(1024 x 768 recommended)
  • 1 RS232 or USB port (where applicable)
  • Mouse
Analogue input channel options Analogue to digital converters: 2
Differential: 8
Single Ended*: 16
3 or 4 wire: 4
Additional channels
* Please refer to our Technical Note for the configuration of these inputs
Pulse: (2 x fast-64kHz)& (2 x slow - 100Hz)
Event/digital: 8 state inputs or 1 x 8 bit binary
Single Ended*: 2
3 or 4 wire: 1 temperature
Logging speed 100 readings / sec on 2 channel
Communication Standard:RS232 ( Auto bauding to 115200 baud)
USB 1.1 & 2.0 compatible
Ethernet: 10/100 base TCP/IP.
Requires external power supply.
External options: GSM, Wifi and PSTN Modems
Analogue inputs Accuracy: (at 25°C) voltage and resistance (± 0.05% readings + 0.025% range)
Common mode rejection: 100dB
Linearity: 0.015%
Input impedance: > 1MO
Series mode line rejection: 50/60Hz 100dB
Analogue - digital conversion Type: Sigma - Delta
Resolution: 24bit
Sampling rate: up to 10, 20* or 100* readings per sec. per ADC. No 100Hz on 1F8
(* with mains rejection off)
Thermistor Ranges Y & U-type: - 50 to 150°C
Pt100/ Pt1000: - 200 to - 850°C (2 wire only on 1F8)
Customer specific thermistor range
Thermocouple Ranges; Differential and Single Ended K-type: - 200 to 1372°C
R-type: - 50 to 1768°C
B-type: 250 to 1820°C
T-type: - 200 to 400°C
S-type: - 50 to 1768°C
C-type: 0 to 2320°C
N-type: - 200 to 1300°C
J-type: -200 to 1200°C
D-type: 0 to 2320°C
Working environment - 30 to 65°C, RH up to 95% (non-condensing
Voltage Ranges; Differential and Single Ended - 0.075 to 0.075V, - 0.15 to 0.15V, - 0.3 to 0.3V, - 0.6 to 0.6V, 0.6 to 1.2V, 0.6 to 2.4V, - 3.0 to 3.0V, - 6.0 to 6.0 V, -6.0 to 12.0V, - 6.0 to 25.0V
High voltage input range 4.0 to 20.0V, 4.0 to 40.0V, 4.0 to 60.0 (max 2 may be selected)
Current Ranges, Differential (Requires external 10O shunt) -30.0 to 30.0mA, 4 to 20mA
Resistance Ranges, all 2 wire 0.0 to 1250O, 0.0 to 5000O, 0.0 to 20000O, 0.0 to 300000O
Resistance range 3 and 4 wire (2F8) 0.0 to 500O, 0.0 to 4000O
Digital/Alarm Output 4 open drain FET (18V 0.1A)
Memory Internal: up tp 128M(up to 14 million readings)
External: Up to 1Gb - removable MMC/ SD ( for transferring internal memory and storing setups only
Internal memory modes Stop when full or overwrite
Calculated channel Up to 16 virtual channels derived from physical input channels
Resolution Up to 6 significant digits
Display/Keypad 128*64 dot graphical display,4 button keypad
Power supply Internal: 6 x AA alkaline batteries
External: 10-18VDC. Reverse and polarity and over-voltage protected
Power consumption@ 9V Sleep mode: 600µA
Logging: 40 - 80 mA
Power output for external device Regulated 5VDC at 50mA or logger supply voltage at 100m
Time and Date In-built clock in 3 formats
Communication Standard: Wireless Ethernet ( Wi-Fi): 802.11b, 2.4GHz, 1 to 14 channels.
Security: Open, WEP(64 or128bi encryption), WPA orWPA2/ 802.11i.
Network: Infrastructure only with specified SSID( external mains power required for Wi-Fi connection)
RS232 ( Auto bauding to 115200 baud)
USB 1.1 & 2.0 compatible
Programming / logger setup Squirrelview or Squirrelview Plus Software
Dimensions (w x d x h), weight 235 mm x 175 mm x 55 mm, 1.2 kg, enclosure material ABS

Please note: SQ2020 is supplied with software, manual, USB cable, wall bracket, batteries and 4 current shunt resistors.

Application Notes

Below features our collection of application notes and case studies involving this product.

Temperature Monitoring For Quality Control of Pet Foods

Data Loggers To Test Torpedoes

Request Pricing & Information

If you need information right away or prefer to speak with a person, call us and one of our Experienced Applications Engineers will be happy to talk with you. You can reach us at 1-800-956-4437 during our normal business hours Monday - Friday from 8am to 6pm (EDT).

After filling out the form below, an applications engineer will contact you within at least one business day.

Indicates a required field.

Fields that are not required are recommended to be filled out so that we can better assist you.

Request Form

Name Address 1
Email Address 2
Phone # City
Company State
Job Title Zip
Fax # Country
Product(s)

of Interest
Application
Additional

Information
Human Verification What is the next number after 3?  
Newsletter Sign Up - Here at CAS Data Loggers we are constantly publishing new articles, and now you can receive monthly emails to see what's new. By signing up for our monthly newsletter, you will also receive the newest application notes where our products are being used and many other resources such as white papers, videos, technical articles and new product information.

Home | About CAS | Policies | Distributor Login | Systems Integrators

©2011 Computer Aided Solutions, LLC.