Data Loggers For All Applications
Data Loggers for All Applications
1 - 800 - 956 - 4437
M-Th 8A-5:30P(EDT)
Fri     8A-4:30P(EDT)
Find a data logger by selecting an application from the list below.
Request Pricing & Information
Home -> TandD -> RTR-500AW Wireless Data Logger Network Base Station

RTR-500AW Wireless Data Logger Network Base Station

Wireless LAN Based Network Data Collector

Product Overview
  • Links wirelessly to RTR-501/502/503/505/574 for downloading data
  • 802.11b/g Wi-Fi Interface
  • FTP and Email data download
  • Email alarm
  • Local alarm in and out connections
Description

The RTR-500NW is a network base station with built-in Wireless LAN Communication. The RTR-500NW can be set up to automatically download recorded data from an RTR-500 Series Wireless Data Logger via wireless communication, and then send that data via a network to an e-mail address, FTP folder or T&D’s own WebStorage server. It can also monitor for warnings and send warning reports across a network to specified addresses.

RTR-500AW Wireless Data Logger Network Base Station


Manufacturer - TandD

Model Number - RTR-500AW

Product Spec Sheet

A Base Unit with built-in Wireless Communication and LAN Capabilities

RTR-500NW is for a wired LAN and the RTR-500AW is for a use with a wireless LAN The Base Units can automatically download recorded data from a Remote Unit (RTR-500 Series Wireless Data Logger) via wireless communication, and then send that data via a network to any location near or far. The wireless communication range between a Remote Unit and a Base Unit, if unobstructed and direct, is about 150 meters [500 ft]. If wireless communication between the Base Unit and Remote Units is poor or you wish to extend the transmission range it is possible to add Repeaters to improve communication.



Downloading Recorded Data

The RTR-500NW/AW Base Units can be set up to carry out a chain of operations where by they periodically download recorded data and/or current readings from Remote Units (RTR-500 Series Wireless Data Logger) and send that data via a network to an e-mail address, FTP folder or to the “T&D WebStorage Service".



Monitoring Current Readings via T&D WebStorage Service

By having the RTR-500NW/AW send the downloaded current readings to the “T&D WebStorage Service” it is possible to view and share data via a web browser. “T&D WebStorage Service ” is a free web-based storage service provided by T&D Corporation.

Register Remote Units and Change Settings via the Network

If after having deployed the Base Unit and operation has begun, you wish to make settings changes or add a new Remote Unit it is still possible from a distance over the network without having to collect the Base Unit.



An Array of Warning Monitoring Functions

If a measurement exceeds one of the set Upper or Lower Limits the RTR-500NW/AW will judge whether or not a warning has occurred. If a warning has occurred notification will be shown by the LED lamp and an e-mail report will be sent.



ALARM LED Lamp

The ALARM LED lamp on the RTR-500NW/AW will come on.

Warning Report Mail

A warning report mail will be sent to the specified e-mail address(es).

External Contact Output (Warning Output)

When the “ALARM” LED lamp goes on, the external output on the RTR-500NW/AW simultaneously switched to ON.It is possible to create a foolproof warning system by connecting a siren, light or other easily understandable warning device to the external output terminal.

External Contact Input

By connecting a sensor such as a motion sensor, light sensor, or open/close sensor to the external input terminal of the RTR-500NW/AW it is possible to detect electric signals (ON /OFF) from outside and create a surveillance system. When an ON signal is detected an warning report mail will be sent.



Up to 100 Remote Units can be Registered

It is possible to organize Remote Units and register them as Groups into an RTR-500NW/AW depending on their location, measurement items, or other category. Up to 10 Groups can be registered into one Base Unit with up to a total of 100 Remote Units registrations possible.

Application Examples

  • For Centralized Monitoring and Management of Temperature and Humidity in Refrigerated Cases across Supermarkets or other Chain Stores
  • For Monitoring Systems of Pharmacy Storage Facilities
  • For Degradation Prevention Systems in Art Museums and other Archival and Exhibit Forums



T&D WebStorage Service is an online service provided by T&D Corporation. By setting up a RTR-500 to transmit recorded data and current readings to T&D's dedicated Internet server, Users can use the WebStorage Service to access and share data anytime from anywhere.

Free Online Service for Data Storage

Experience the convenience of sharing recorded data via the Internet! Perfect for processing and managing data recorded in remote places or for allowing several people to view the same recorded data at their convenience. Recorded data can be transmitted to T&D WebStorage Service from the RTR-500.

The data transmitted to T&D WebStorage Service can be accessed via your browser from anywhere, anytime, as long as an internet connection is available.

Application Examples

One perfect example to show the system's unique power is the "Temperature Management of Products while in Transit".

Here, using RTR-500 as an example, T&D WebStorage Service enables the "Sender", the "Receiver", and the "Carrier" to monitor the same current readings graph and check the temperature condition of the products while in transit.

Access your Recorded Data and Current Readings anytime from anywhere and experience the greatness of the new T&D WebStorage Service!

1: Antenna
2: Optical Communication Area
3: POWER LED
4: ACTIVE LED
5: DIAG (Diagnosis) LED
6: ALARM LED
7: External Input Terminal
8: External Output Terminal
9: USB Mini Connector (Mini-B)
10:AC Adaptor Jack

RTR-500NW/AW (FCC model / CE model)
Compatible Devices Remote Units:
RTR-501/502/503/574/505-TC/505-Pt/505-V/505-mA/505-P,
RTR-501L/502L/503L/505-TCL/505-PtL/505-VL/505-mAL/505-PL
Repeater: RTR-500
Features and Functions 1. Auto-downloading of Recorded Data (E-mail /FTP)
2. Automatic Sending of Current Readings (E-mail / FTP)
3. Warning Monitoring (E-mail / Contact)
Types of Warnings Remote Unit Measurement Warnings,
Cumulative Illuminance/Amount of UV Light Warnings (RTR-574),
Remote Unit Wireless Communication Error Warnings,
Remote Unit Battery Level Warnings,
Remote Unit Sensor Error Warnings,
Base Unit External Contact Input Warnings
Power AC Adaptor AD-0638 or AD-0638-C
Current Consumption RTR-500NW: Approx. 300mA
RTR-500AW: Approx. 400mA
Communication Interface USB (with PC)
Optical Communication (with Compatible Remote Units other than RTR-574)
Wired LAN (RTR-500NW)
Wireless LAN (RTR-500AW)
LED Indicator POWER, ACTIVE, DIAG, ALARM
Dimensions H83mm x W102mm x D28mm (excluding protrusions)
Antenna Length: 87.3mm
Weight RTR-500NW: About 130g
RTR-500AW: About 120g
(including antenna for each)
Operating Environment Temperature : -10 to 60 °C
Humidity : 20 to 80%RH (no condensation)
Other Not waterproof, moistureproof, or dustproof.
Short Range Wireless Communication
RF Power FCC model 7mW / CE model 5mW
Radio Standard Specifications FCC Part15 Section247 / IC RSS-210 (Frequency Range: 902 to 928MHz )
ETSI EN 300 220 (Frequency Range: 869.7 to 870MHz)
Transmission Range About 150 meters (500 ft) (if direct and unobstructed)
Communication Time When downloading one Remote Unit at full logging capacity:
RTR-501/501L/502/502L/503/503L: About 2 min.*
RTR-574: About 4 min.*
* The same amount of time will be necessary for each added Repeater.
Data Transfer Protocol Auto-Downloading of Recorded Data / Auto-Sending of Current Readings:
FTP (PASV mode also supported)
SMTP (SMTP-AUTH, POP-before SMTP)
*SMTP-AUTH supports LOGIN only
Warning Monitoring:
SMTP (SMTP-AUTH, POP-before SMTP)
*SMTP-AUTH supports LOGIN only
LAN Communication Specifications
Wired LAN (RTR-500NW) RJ45 Connector
100Base-TX / 10Base-T AutoMDI / MDI-X
Wireless LAN (RTR-500AW) Internal wireless LAN antenna IEEE 802.11b/g WEP, WPA/WPA2 (PSK)
Contacts (Warning Output/Input)
Output Terminal Voltage when OFF: DC less than 50V
Current when ON: less than 0.1A or less
Resistance when ON: 15O
Input Terminal Internal Pull-up : 3V 100kO
Maximum Input Voltage : 30V

Software Package

RTR-500 for Windows
  • RTR-500W for Windows
  • RTR-500W Settings Utility
  • Temperature / Humidity Graph
  • Multi-Scale Graph
  • Data Download Tool
  • Adjustment Tools

"Settings Utility" Program makes Settings a Snap!

The Settings Utility application is used to take care of all Base Unit settings and registration of Remote Units and Repeaters. After having registered and placed the Remote Units and Repeaters in the field, it is possible to run communication tests to check signal strength between the various units to ensure stable communication.

Easy-to-Understand Operation Guide

The Operation Guide that is part of the software uses easy to understand terms to help lead you through all the necessary steps and setting procedures. If during setup you get confused or have trouble, just simply open the Operation Guide in the same on-screen window and make settings while consulting the Guide.

Difficult Cellular Phone Network Settings made Easy

When using the RTR-500GSM, we have included an “Initial Settings Wizard” which guides you through what otherwise would be the difficult process of setting up the unit for GSM network communication; just put in the SIM Card and turn on the Wizard.

Intuitive User-Friendly Graph Tools (Temperature / Humidity Graph and Multi-Scale Graph)

With either program you can view up to eight channels of data in one graph.The Graph programs intuitive operation allows the User to easily hide or view channels, zoom in and out on data, switch back and forth from °C to °F, and view data in table form.

View in Table Form

Graph data can be easily viewed as a data list. The highest and lowest values are shown in easily distinguishable colors.

From Graph Editing to Data Analysis

It is possible to hide, re-order and delete channels, edit recording start times, and make changes to colors used for the graph scale lines, data lines and background. Also move the A and B cursor at the bottom of the graph to view data readings for those points and the calculated difference between the points.By saving graph data as CSV Format Text File data, that data can then be uploaded into common spreadsheet software for data analysis.

Remote Unit Adjustment Settings

When using multiple measuring devices, this function allows the user to correct for inaccuracies found in measured values when compared to a standard measurement (the value measured by the standard device). Measurements can be adjusted and recorded based on a standard measurement. The RTR-500 Series Software allows for adjustment settings to be made to Remote Unit measurements by simply selecting the adjustment method from either "1 Point Adjustment" or "2 Point Adjustment" and entering the values for "Before Adjustment” and "After Adjustment".

Wall Attachment (TR-5WK1)

(1) Materials: PC Resin
(2) Screw for fastening to wall x 2
(3) Double-sided Tape x 1
(4) Screw for fastening Unit x 1
Dimensions:
W106 x H86 x D17.8mm
Screw Holes: 2 - Φ3.2mm

Request Pricing & Information

If you need information right away or prefer to speak with a person, call us and one of our Experienced Applications Engineers will be happy to talk with you. You can reach us at 1-800-956-4437 during our normal business hours Monday - Friday from 8am to 6pm (EDT).

After filling out the form below, an applications engineer will contact you within at least one business day.

Indicates a required field.

Fields that are not required are recommended to be filled out so that we can better assist you.

Request Form

Name Address 1
Email Address 2
Phone # City
Company State
Job Title Zip
Fax # Country
Product(s)

of Interest
Application
Additional

Information
Human Verification What is the next number after 1?  
Newsletter Sign Up - Here at CAS Data Loggers we are constantly publishing new articles, and now you can receive monthly emails to see what's new. By signing up for our monthly newsletter, you will also receive the newest application notes where our products are being used and many other resources such as white papers, videos, technical articles and new product information.

Home | About CAS | Policies | Distributor Login | Systems Integrators

©2011 Computer Aided Solutions, LLC.