The Madgetech Motor101 data logging system provides a complete solution for monitoring runtime on motors or other equipment drawing up to 200 amps. It includes a built in current switch that is triggered when the incoming current is > 150mA and a event data logger that can record up to 32,767 state changes. It can be programmed to look for state changes from 1x second up to once every 12 hours. It is available in 2 versions, the Motor101-C which is a complete kit including sensor, logger, software and interface cable or the Motor 101-NC which includes the sensor and logger only.
|
|
|
|
TandD RVR-52
The RVR-52 data logger is a compact, water-resistant, wireless, voltage logger with a range of 0 V
to 6.5 V. An optional input cable allow the measurement of 4-20 mA current loops. This compact logger can store up to 16,000 data points and connects to a PC through the RTR-57U
Wireless Data Collector, the RTR-5W Wireless Data Collector, or the
RTR-50 Wireless USB Base Station/Repeater
|
|
|
TandD VR-71
The VR-71 is a 2-channel voltage data logger, with a range of ±1 V, ±2 V, ±6 V,
or ±15 V per channel. An optional input cable allows measurement of 4-20 mA current loops. The VR-71 has 20 programmable sampling rates from 20 Hz to once per hour
and stores up to 8,000 data points per channel. The optional VR-00P1 expansion module allow for an external sensor excitation signal to be
switched on and off and can synchronize up to 4 VR-71 units.
|
|
|
Eltek
Eltek offer wireless transmitters and receivers for voltage and current measurements
GS-41F - 1 voltage/current input
GS-42F - 2 voltage/current inputs
GS-44F - 4 voltage/current inputs
|
General Purpose Data Loggers suitable for voltage or current measurements
|
|
|
dataTaker DT80 Series
The DT80 series data loggers have ±300 mV to ±30-Volt input ranges with a built-in display and a
USB memory slot for easy data transfer. It also can measure 4-20 mA current loops with internal or external shunt resistors. The DT80 Series are stand-alone data loggers that
connect to a PC via Ethernet, USB, or RS-232.
DT80 5 to 15 analog inputs for voltage or current, 12 digital channels, 1 serial sensor channel
DT81 1 to 3 analog inputs for voltage or current, 4 digital channels, 4 counter channels

|
|
|
dataTaker DT800
The DT800 data logger is has 12 to 42 analog input channels, 16 digital channels, and 1
serial sensor channel. The DT800 stores up to 130,000,000 data points and has an ATA Flash
card slot for removable data storage. For voltage or current measurements, the DT800 can accept up to 42 single ended inputs or 24
differential inputs.
|
|
|
dataTaker DT50 Series
The DT50 series data loggers have up to 5 low-voltage input channels that are suitable for
voltage, 4-20 mA current, thermocouple, RTD or thermistor measurements. The DT50 series data loggers also have digital
and counter inputs, stores up to 130,000 points in internal memory, and require an RS-232 port for connection to a PC.
DT50 5 to 15 analog inputs for voltage or current, 5 digital channels, 3 counter channels, SRAM PC Card slot for Removable Data Storage
DT51 1 to 3 analog inputs for voltage or current, 4 digital channels, 3 counter channels

|
|
|
dataTaker DT500/DT600 Series
The DT500/DT600 series data loggers have 10 to 30 analog input channels for voltage or current
plus 4 digital channels and 3 counter channels. Each store up to 1,390,000 data points and have an SRAM PC card slot for removable data
storage. Optional expansion modules allow up to a 90 channels of voltage or current inputs.
DT500 ±2.5 V Input Measurement Range
DT505 ±100 V Input Measurement Range
DT600 ±2.5 V Input Measurement Range, with built-in display
DT605 ±100 V Input Measurement Range, with built-in display

|
|
|
Grant Squirrel SQ2020/SQ2040 Series
The Grant Squirrel SQ2020/SQ2040 series data loggers are capable of sub-second logging and
concurrent sampling. With 16 MB of internal memory, the Grant Squirrel SQ2020/SQ2040 series data
loggers can log approximately 1,000,000 to 2,000,000 readings that can be downloaded to a removable MMC memory card. Inputs can be
used with voltage signals, thermistor, thermocouple and RTD temperature sensors and 4-20mA current loops.
SQ2010 4 Differential or 8 single ended analog inputs for voltage or current
SQ2020-1F8 8 Differential or 16 single ended analog inputs for voltage or current with a single ADC
SQ2020-2F8 8 Differential or 16 single ended analog inputs for voltage or current with two ADC's
SQ2040-2F16 16 Differential or 32 single ended analog inputs for voltage or current with two ADC's
SQ2040-4F16 16 Differential or 32 single ended analog inputs for voltage or current with four ADC's

|
|
|
KineticSystems DAQ400/DAQ500 Series
The portable KineticSystems DAQ400/DAQ500 Series data loggers have 4 to 64 voltage channels. The KineticSystems DAQ400/DAQ500 Series data loggers can interface to a PC or operate standalone, and stores data on a removable CompactFlash™ card. It supports sample rates
of up to 50-kHz aggregate.
DAQ432 32 Input channels with programmable gain and 4 kHz aggregate sample rate
DAQ464 64 Input channels with programmable gain and 4 kHz aggregate sample rate
DAQ504 4 Input channels with programmable gain and 50 kHz aggregate sample rate
DAQ516 16 Input channels with fixed gain and 50 kHz aggregate sample rate
DAQ518 18 Input channels 16 with fixed gain, 2 with programmable gain and 50 kHz aggregate sample rate
DAQ532 32 Input channels with fixed gain and 50 kHz aggregate sample rate

|
|
|
Nimtech FrontDAQ
The Nimtech FrontDAQ data logger has 20 analog input channels for voltage or 4-20 mA current, 20 digital
channels and 4 analog outputs. The Nimtech FrontDAQ data logger can sample at 7.7 kHz per channel
and store data to CompactFLASH™ memory. The Nimtech FrontDAQ data logger is network-ready and incorporates an internal web server
for setting up and viewing data.

|
|
|
Infinite Informatics iLOG Series
The iLOG series data loggers are 4-channel data logger that can accomodate RTD, PT100, 0-1 Volt,
0-20 mA, or 4-20 mA input types. The iLOG series data loggers incorporate an internal web server
with FTP and email support which makes it ideal for remote temperature logging applications.
iLOG-EDM Serial port interface for external modems
iLOG-GSM Built-in GSM/GPRS modem
iLOG-LAN Eterhnet interface for network connectivity

|
Paperless Chart Recorders |

VR06
Product Specifications
|
6.4" VGA Color LCD display
Up to 6 input channels for voltage, current, thermocouple or RTD
6 Plug and Play I/O card slots
Standard Ethernet and optional RS-232/RS-422/RS485 communication
Removable Compact Flash data storage
Multiple display formats
Panel mount and bench top/portable configurations
Prices starting at $1150
 |

VR18
Product Specifications
|
6.1" VGA Color LCD display
Up to 18 input channels for voltage, current, thermocouple or RTD
6 Plug and Play I/O card slots
Standard Ethernet and optional RS-232/RS-422/RS485 communication
Removable Compact Flash data storage
Multiple display formats
Panel mount and bench top/portable configurations