TandD RTR-505B-Pt

  • Records from -199 to 600°C
  • Accuracy: ±0.3°C + 0.3% of reading (at 10 to 40°C)
  • Logging capacity: 16,000 readings
  • Measures in both °C, °F
  • Wireless communication range of up to 150 meters (500 feet)
  • LCD Display
  • Battery life of about 10 months
  • Additional Base Station required for communication

TandD RTR-505B-P

  • Logging Capacity: 16,000 readings
  • Capable of counting up to 61,439 pulses per reading
  • Pulse Response: Max of 3,500 pulses per second
  • Voltage Signals: 0 to 27V
  • Lo: 0.5V or less, Hi 2.5V or more
  • Contact signals also recordable
  • Wireless communication range of up to 150 meters (500 feet)
  • LCD Display
  • Battery life of about 10 months
  • WebStorage Service available
  • Additional Base Station required for communication

TandD RTR-505B-mA

  • Measures 0 to 20mA (Operational up to 40mA)
  • Recording modes: instantaneous or average
  • Logging capacity: 16,000 readings
  • Wireless communication range of up to 150 meters (500 feet)
  • LCD Display
  • Battery life of about 10 months
  • Data can be collected remotely via: USB, GSM technology, LAN and handheld data collectors
  • WebStorage Service available
  • Additional Base Station required for communication

TandD RTR-505B-V

  • Measures from 0 to 22V
  • Recording modes: instantaneous or average
  • Logging capacity: 16,000 readings
  • Wireless communication range of up to 150 meters (500 feet)
  • LCD Display
  • Battery life of about 10 months
  • Battery life can be upgraded to about 4 years
  • Comes with options for wall mounts
  • Data can be collected remotely via: USB, GSM technology, LAN and handheld data collectors
  • WebStorage Service available
  • Additional Base Station required for communication

TandD RTR-505B-TC

  • Cold Junction Compensation
  • Thermocouple Measurement Range:
    • K: -199 to 1370 °C, J: -199 to 1200 °C
    • T: -199 to 400 °C, S: -50 to 1760 °C
  • Thermocouple Accurary:
    • Type K, J, T: ± 0.3°C and 0.3% of reading
    • Type S: ±1°C + 0.3% of reading
  • Logging capacity: 16,000 readings
  • LCD Display
  • Battery Life: About 10 Months
  • Additional Base Station required for communication

TandD RTR-505-TC

  • Cold Junction Compensation
  • Module temperature at 10°C to 40°C: ±0.3°, At other temps: 0.5°C
  • Thermocouple Measurement
    • Type K, J, T: ± 0.3% of reading
    • Type S: ±1°C + 0.3% of reading
  • Storage: 16,000 readings
  • LCD Display
  • Battery Life: About 10 Months

TandD RTR-505-V

  • Measures from 0 to 22V
  • Recording modes: instantaneous or average
  • 16,000 point memory
  • Wireless communication range of up to 150 meters (500 feet)
  • LCD Display
  • Battery life of about 10 months
  • Battery life can be upgraded to about 4 years
  • Comes with options for wall mounts

TandD RTR-505-mA

  • Measures 0 to 20mA (Operational up to 40mA)
  • Recording modes: instantaneous or average
  • 16,000 point memory
  • Measures in both °C, °F
  • Wireless communication range of up to 150 meters (500 feet)
  • LCD Display
  • Battery life of about 10 months

TandD RTR-505-P

  • Logging Capacity: 16,000 readings
  • Capable of counting up to 61,439 pulses per reading
  • Pulse Response: Max of 3,500 pulses per second
  • Voltage Signals: 0 to 27V
  • Lo: 0.5V or less, HiL 2.5V or more
  • Contact signals also recordable
  • 16,000 point memory
  • Wireless communication range of up to 150 meters (500 feet)
  • LCD Display
  • Battery life of about 10 months

TandD RTR-505-Pt

  • Records from -199 to 650°C
  • Module temperature at 10 to 40°C: ±0.3°C + 0.3% of reading
  • Other temperatures: ±0.5°C + 0.3% of reading
  • 16,000 point memory
  • Measures in both °C, °F
  • Wireless communication range of up to 150 meters (500 feet)
  • LCD Display
  • Battery life of about 10 months