Delphin LoggitoLab Logger

  • Plug & Play – Flexible and ready-to-use desktop device with universal analog inputs and combined digital inputs/outputs
  • Optional laboratory and/or miniature thermal sockets to easily connect any current/voltage and temperature signals
  • Maximum measuring precision and resolution
  • Integrated server capability to instantly visualize and analyze measurement data via smartphone or tablet.
  • Versatile interfaces: LAN, USB, WLAN, OPC UA, Modbus TCP
  • Easy extendibility and scalability when extra channels needed
  • Optional internal data memory

Call for configuration and price. 1-800-956-4437

Description

Accessing measurement data on the go

LoggitoLab Logger is the device of choice when users require PC-independent operation with fail-safe internal data storage and smart analysis functions. The LoggitoLab Logger also features an optional server capability allowing measurement data to be instantly visualized and analyzed on smartphones or tablets. The optional WLAN interface allows full independence from existing network infrastructures.

Connection variants for your application

LoggitoLab provides the ideal solution for any application, whether for laboratory sockets for connecting voltage, current, resistance signal, or for miniature thermal sockets for instant connection of any thermocouples, or for a combination of both. All connection variants have eight analog inputs and two software-switchable digital inputs/outputs. A special feature is that the connection variants are available for both the LoggitoLab Logger and for the LoggitoLab USB. You and your application, therefore, benefit from maximum flexibility.

Connection variant: 8 AI-RTD with eight universal analog inputs to connect any voltage, current, and RTD signals in 2-, 3- and 4-wire technology via 4 mm lab sockets.

 

 

 

 

Connection variant: 8 TC with eight analog inputs for direct connection and high-precision measurement of any thermocouples via miniature thermal sockets.

 

 

 

 

Connection variant: 4 AI-RTD 4 TC for full flexibility with a combination of 4 analog inputs with 4 mm laboratory sockets and 4 analog inputs with miniature thermal sockets.

 

 

 

 

 

Specifications

Connection variant 8 AI-RTD 8 TC 4 AI-RTD TC
Analog inputs (mV, mA, thermocouples, RTDs) 8 0 4
Analog inputs (thermocouples) 0 8 4
Total sampling rate 0.1 Hz … 500 Hz
Voltage measurement range ±78 mV .. ±10 V
Current measuring range 0 .. 20 mA / 4 .. 20 mA / ±20 mA / any (with freely selectable external shunts)
Resistance measurement range 0 .. 49 kΩ
Resolution/Type ADC 24-bit Sigma-Delta
Input Impedance > 5 GΩ
Dielectric withstand voltage (tolerable overvoltage) ±24 VDC
Max. differential voltage channel to channel ±24 VDC
Galvanic isolation against FE ±400 VDC
Precision of current and voltage measurement 0.01% from upper range value
Precision resistance measurement 0.01% from upper range value (4-wire connection), 0.1% from upper range value (3-wire connection after additional offset determination)
RTD Precision 0.1 K (4-wire connection), 1 K (3-wire connection)
Digital/frequency inputs or rather Digital/PWM outputs (switchable) 2 2 2
Input Signal low: 0 .. 1 V / high: 3,6 .. 100 VDC@3,5 mA
Frequency input measuring range 0.2 Hz .. 500 Hz
Counter width 64 bit
Max. switching voltage / current 50 V / 2.5 A for 2 seconds, 250 mA continuous current
PWM basic frequency / duty cycle 100 Hz / 1:20
Galvanic isolation ±400 VDC against FE / other channel groups
Model type LoggitoLab Logger LoggitoLab USB
Interfaces
LAN 100Base-Tx
WLAN 802.11b/g/n, max. 72 Mbit/s (optional
USB device – mini socket 2.0 low/full/high speed 2.0 low/full speed
USB host – type A socket 2.0 low/full/high speed
Protocols
TCP/IP Modbus TCP server & client, OPC UA client, OPC UA server, NP, SMTP, PTP
Data Storage
Internal 4 / 8 GB (approx. 30 million measurement values per GB)
External USB, NFS, CIFS, (S)FTP
General technical information
Dimensions approx. L 150 mm x W 190 mm x H 80 mm
Weight approx. 800g
Temperature range -20 .. 60° C
Humidity max. 90 % relative humidity, non-condensing
Supply voltage 12 .. 24 VDC / ±10 % 5 VDC (via mini USB connector)
Power input max. 7.5 watts max. 2.5 watts

Software

Online analysis, monitoring, and automation

The LoggitoLab Logger is equipped with integrated software channels for online analysis, monitoring, and automation functions. By using the ProfiSignal 20 software, a multitude of web functions can be realized. The software provides users with a powerful PC-based tool for measurement technology.

Software channels in the LoggitoLab Logger

  • Online processing during acquisition using internal software channels
  • Calculation and statistical channels compute, monitor, count, and integrate measurement data
  • Limit detector to monitor limit and limit values
  • Status detector to evaluate status information and to issue alerts in the event of an mA-signal failure
  • A trigger automatically performs setpoint curves with reset, stop/start triggers
  • Timer channels provide, for example, time-delayed starts for experiment procedures

ProfiSignal 20: Live measurement data on any user device

  • Mobile access to live measurement data from any user device
  • Live data, historical data, process parameters in an individually adjustable dashboard
  • Data storage capacity with cloud functions within the LoggitoLab Logger (measurement technology for edge cloud computing)
  • Online and off-line analysis and visualization of measurement data
  • Creation of automated testing procedures