Pushing Data via FTP Using the Delphin Expert Logger

Send Data Directly to Your Office PC!

FTPFile Transfer Protocol–is a widely-used network protocol for file transfer and managing of directories. For example it’s often used to create, delete, and share files. In this latest Tech Article from CAS DataLoggers we detail how you can use a Delphin Expert Logger to configure a data transfer via FTP to the Cloud or to another server within the network.

 

FTP Push With the Expert Logger:

Step 1: Create a ‘Drive’ in the Delphin DataService Configurator.

pushing-data-ftp-delphin-expert-logger

Step 2: Configure the ‘Drive’ in the configurations dialog.

pushing-data-ftp-delphin-expert-logger-2

Please note that you must select the Drive ‘Network’.

For this setting, it is essential that you enter a network address and a path.

Step 3: Reference ‘DriveFTP_Test’ with an already-existing storage group within the device.

pushing-data-ftp-delphin-expert-logger-3

Step 4: Import the saved data on the FTP server in a readable format.

You need to convert the saved file from a raw to a readable format (e.g.”*.hds” or “*.csv”). An ‘*.ExternalDatastorage-xml’ file will be located at the saved path. You can perform the conversion using the ‘Data converter’ program. This program is supplied as a standard program within ProfiSignal.

pushing-data-ftp-delphin-expert-logger-4

Delphin Technologies:

Delphin Technologies data loggers solve a variety of measurement and control problems in industrial and laboratory applications. They feature different analog and digital I/O modules for use with a wide range of signal types including: voltage; 4-20 mA current; thermocouple; RTD; and resistance. They also offer powerful alarm and programming capabilities allowing them to process measurements and to initiate actions on their own.

Delphin systems can be used for local data acquisition and logging when connected to a PC; for remote unattended data collection connected the internet; or as stand-alone devices. Delphin products are used worldwide in the following ways:

  • Delphin Message devices for industrial measurement data acquisition
  • ProfiSignal software for test bench automation
  • The AMDT – module for vibration monitoring and analysis
  • Remote monitoring of plant and machinery using ProfiSignal Go software
  • Operating DAQ and intelligent processing within Message devices
  • Supplying individual solutions (mobile, control cabinets, 19-inch etc.)
  • Developmental services (processing, user interfaces, databases)
  • Start-ups and training